Agamemnon Krasoulis

Dr. Agamemnon Krasoulis

Newcastle University
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 July 2017 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
AKAgamemnon Krasoulis
Agamemnon Krasoulis
IKIris Kyranou
Iris Kyranou
MEMustafa Suphi Erden
Mustafa Suphi Erden
KNKianoush Nazarpour
Kianoush Nazarpour
SVSethu Vijayakumar
Sethu Vijayakumar
Myoelectric pattern recognition systems can decode movement intention to drive upper-limb prostheses. Despite recent advances in academic research, the commercial adoption of such systems remains low. This limitation is mainly due to the lack of classification robustness and a simultaneous requirement for a large number of electromyogram (EMG) electrodes. We propose to address these two issues by using a multi-modal approach which combines surface electromyography (sEMG) with inertial measurements (IMs) and an appropriate training data collection paradigm. We demonstrate that this can significantly improve classification performance as compared to conventional techniques exclusively based on sEMG signals. We collected and analyzed a large dataset comprising recordings with 20 able-bodied and two amputee participants executing 40 movements. Additionally, we conducted a novel real-time prosthetic hand control experiment with 11 able-bodied subjects and an amputee by using a state-of-the-art commercial prosthetic hand. A systematic performance comparison was carried out to investigate the potential benefit of incorporating IMs in prosthetic hand control. The inclusion of IM data improved performance significantly, by increasing classification accuracy (CA) in the offline analysis and improving completion rates (CRs) in the real-time experiment. Our findings were consistent across able-bodied and amputee subjects. Integrating the sEMG electrodes and IM sensors within a single sensor package enabled us to achieve high-level performance by using on average 4-6 sensors. The results from our experiments suggest that IMs can form an excellent complimentary source signal for upper-limb myoelectric prostheses. We trust that multi-modal control solutions have the potential of improving the usability of upper-extremity prostheses in real-life applications.

10 September 2019 in Frontiers in Neuroscience
Verified
Journal Article
Open access
AKAgamemnon Krasoulis
Agamemnon Krasoulis
SVSethu Vijayakumar
Sethu Vijayakumar
KNKianoush Nazarpour
Kianoush Nazarpour
Machine learning-based myoelectric control is regarded as an intuitive paradigm, because of the mapping it creates between muscle co-activation patterns and prosthesis movements that aims to simulate the physiological pathways found in the human arm. Despite that, there has been evidence that closed-loop interaction with a classification-based interface results in user adaptation, which leads to performance improvement with experience. Recently, there has been a focus shift towards continuous prosthesis control, yet little is known about whether and how user adaptation affects myoelectric control performance in dexterous, intuitive tasks. We investigate the effect of short-term adaptation with independent finger position control by conducting real-time experiments with 10 able-bodied and two transradial amputee subjects. We demonstrate that despite using an intuitive decoder, experience leads to significant improvements in performance. We argue that this is due to the lack of an utterly natural control scheme, which is mainly caused by differences in the anatomy of human and artificial hands, movement intent decoding inaccuracies, and lack of proprioception. Finally, we extend previous work in classification-based and wrist continuous control by verifying that offline analyses cannot reliably predict real-time performance, thereby reiterating the importance of validating myoelectric control algorithms with real-time experiments.

1 April 2015
Verified
Conference Paper
Closed access
AKAgamemnon Krasoulis
Agamemnon Krasoulis
SVSethu Vijayakumar
Sethu Vijayakumar
KNKianoush Nazarpour
Kianoush Nazarpour
The reconstruction of finger movement activity from surface electromyography (sEMG) has been proposed for the proportional and simultaneous myoelectric control of multiple degrees-of-freedom (DOFs). In this paper, we propose a framework for assessing decoding performance on novel movements, that is movements not included in the training dataset. We then use our proposed framework to compare the performance of linear and kernel ridge regression for the reconstruction of finger movement from sEMG and accelerometry. Our findings provide evidence that, although the performance of the non-linear method is superior for movements seen by the decoder during the training phase, the performance of the two algorithms is comparable when generalizing to novel movements.

20 January 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
DBDimitra Blana
Dimitra Blana
ABAntonie J. Van Den Bogert
Antonie J. Van Den Bogert
WMWendy M. Murray
Wendy M. Murray
AGAmartya Ganguly
Amartya Ganguly
AKAgamemnon Krasoulis
Agamemnon Krasoulis
ECEdward K. Chadwick
Edward K. Chadwick
Prosthetic devices for hand difference have advanced considerably in recent years, to the point where the mechanical dexterity of a state-of-the-art prosthetic hand approaches that of the natural hand. Control options for users, however, have not kept pace, meaning that the new devices are not used to their full potential. Promising developments in control technology reported in the literature have met with limited commercial and clinical success. We have previously described a biomechanical model of the hand that could be used for prosthesis control. The goal of this study was to evaluate the feasibility of this approach in terms of kinematic fidelity of model-predicted finger movement and the computational performance of the model. We show the performance of the model in replicating recorded hand and finger kinematics and find average correlations of 0.89 between modelled and recorded motions; we show that the computational performance of the simulations is fast enough to achieve real-time control with a robotic hand in the loop; and we describe the use of the model for controlling object gripping. Despite some limitations in accessing sufficient driving signals, the model performance shows promise as a controller for prosthetic hands when driven with recorded EMG signals. User-in-the-loop testing with amputees is necessary in future work to evaluate the suitability of available driving signals, and to examine translation of offline results to online performance.

26 September 2022 in Journal of Chemical Information and Modeling
Verified
Journal Article
Closed access
AKAgamemnon Krasoulis
Agamemnon Krasoulis
NANick Antonopoulos
Nick Antonopoulos
VPVassilis Pitsikalis
Vassilis Pitsikalis
STStavros Theodorakis
Stavros Theodorakis

9 October 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AKAgamemnon Krasoulis
Agamemnon Krasoulis
KNKianoush Nazarpour
Kianoush Nazarpour
The ultimate goal of machine learning-based myoelectric control is simultaneous and independent control of multiple degrees of freedom (DOFs), including wrist and digit artificial joints. For prosthetic finger control, regression-based methods are typically used to reconstruct position/velocity trajectories from surface electromyogram (EMG) signals. Unfortunately, such methods have thus far met with limited success. In this work, we propose action decoding, a paradigm-shifting approach for independent, multi-digit movement intent prediction based on multi-output, multi-class classification. At each moment in time, our algorithm decodes movement intent for each available DOF into one of three classes: open, close, or stall (i.e., no movement). Despite using a classifier as the decoder, arbitrary hand postures are possible with our approach. We analyse a public dataset previously recorded and published by us, comprising measurements from 10 able-bodied and two transradial amputee participants. We demonstrate the feasibility of using our proposed action decoding paradigm to predict movement action for all five digits as well as rotation of the thumb. We perform a systematic offline analysis by investigating the effect of various algorithmic parameters on decoding performance, such as feature selection and choice of classification algorithm and multi-output strategy. The outcomes of the offline analysis presented in this study will be used to inform the real-time implementation of our algorithm. In the future, we will further evaluate its efficacy with real-time control experiments involving upper-limb amputees.