Ahmed Alshaikhsalama

Dr. Ahmed Alshaikhsalama


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2022 in Bone & Joint Open
Verified
Journal Article
Open access
HAHolden Archer
Holden Archer
SRSeth Reine
Seth Reine
AAAhmed Alshaikhsalama
Ahmed Alshaikhsalama
JWJoel Wells
Joel Wells
AKAjay Kohli
Ajay Kohli
ACAvneesh Chhabra
Avneesh Chhabra
Aims: Hip dysplasia (HD) leads to premature osteoarthritis. Timely detection and correction of HD has been shown to improve pain, functional status, and hip longevity. Several time-consuming radiological measurements are currently used to confirm HD. An artificial intelligence (AI) software named HIPPO automatically locates anatomical landmarks on anteroposterior pelvis radiographs and performs the needed measurements. The primary aim of this study was to assess the reliability of this tool as compared to multi-reader evaluation in clinically proven cases of adult HD. The secondary aims were to assess the time savings achieved and evaluate inter-reader assessment. Methods: A consecutive preoperative sample of 130 HD patients (256 hips) was used. This cohort included 82.3% females (n = 107) and 17.7% males (n = 23) with median patient age of 28.6 years (interquartile range (IQR) 22.5 to 37.2). Three trained readers’ measurements were compared to AI outputs of lateral centre-edge angle (LCEA), caput-collum-diaphyseal (CCD) angle, pelvic obliquity, Tönnis angle, Sharp’s angle, and femoral head coverage. Intraclass correlation coefficients (ICC) and Bland-Altman analyses were obtained. Results: Among 256 hips with AI outputs, all six hip AI measurements were successfully obtained. The AI-reader correlations were generally good (ICC 0.60 to 0.74) to excellent (ICC > 0.75). There was lower agreement for CCD angle measurement. Most widely used measurements for HD diagnosis (LCEA and Tönnis angle) demonstrated good to excellent inter-method reliability (ICC 0.71 to 0.86 and 0.82 to 0.90, respectively). The median reading time for the three readers and AI was 212 (IQR 197 to 230), 131 (IQR 126 to 147), 734 (IQR 690 to 786), and 41 (IQR 38 to 44) seconds, respectively. Conclusion: This study showed that AI-based software demonstrated reliable radiological assessment of patients with HD with significant interpretation-related time savings. Cite this article: Bone Jt Open 2022;3(11):877–884.

4 March 2024 in Ophthalmology Retina
Verified
Journal Article
Closed access
AAAhmed Alshaikhsalama
Ahmed Alshaikhsalama
KTKrista N. Thompson
Krista N. Thompson
HPHank Patrick
Hank Patrick
JLJessica Lee
Jessica Lee
TVTamara A. Voor
Tamara A. Voor
AWAngeline L. Wang
Angeline L. Wang

9 December 2024 in Ophthalmology Retina
Verified
Journal Article
Closed access
AAAhmed Alshaikhsalama
Ahmed Alshaikhsalama
AAAmer F. Alsoudi
Amer F. Alsoudi
KWKaren Wai
Karen Wai
EKEuna Koo
Euna Koo
PMPrithvi Mruthyunjaya
Prithvi Mruthyunjaya
EREhsan Rahimy
Ehsan Rahimy

20 December 2024 in World Journal of Experimental Medicine
Verified
Journal Article
Open access
AAAhmed Alshaikhsalama
Ahmed Alshaikhsalama
HAHolden Archer
Holden Archer
YXYin Xi
Yin Xi
RLRichard Ljuhar
Richard Ljuhar
JWJoel E Wells
Joel E Wells
ACAvneesh Chhabra
Avneesh Chhabra
BACKGROUND Hip dysplasia (HD) is characterized by insufficient acetabular coverage of the femoral head, leading to a predisposition for osteoarthritis. While radiographic measurements such as the lateral center edge angle (LCEA) and Tönnis angle are essential in evaluating HD severity, patient-reported outcome measures (PROMs) offer insights into the subjective health impact on patients. AIM To investigate the correlations between machine-learning automated and manual radiographic measurements of HD and PROMs with the hypothesis that artificial intelligence (AI)-generated HD measurements indicating less severe dysplasia correlate with better PROMs. METHODS Retrospective study evaluating 256 hips from 130 HD patients from a hip preservation clinic database. Manual and AI-derived radiographic measurements were collected and PROMs such as the Harris hip score (HHS), international hip outcome tool (iHOT-12), short form (SF) 12 (SF-12), and Visual Analogue Scale of the European Quality of Life Group survey were correlated using Spearman's rank-order correlation. RESULTS The median patient age was 28.6 years (range 15.7-62.3 years) with 82.3% of patients being women and 17.7% being men. The median interpretation time for manual readers and AI ranged between 4-12 minutes per patient and 31 seconds, respectively. Manual measurements exhibited weak correlations with HHS, including LCEA (r = 0.18) and Tönnis angle (r = -0.24). AI-derived metrics showed similar weak correlations, with the most significant being Caput-Collum-Diaphyseal (CCD) with iHOT-12 at r = -0.25 (P = 0.042) and CCD with SF-12 at r = 0.25 (P = 0.048). Other measured correlations were not significant (P > 0.05). CONCLUSION This study suggests AI can aid in HD assessment, but weak PROM correlations highlight their continued importance in predicting subjective health and outcomes, complementing AI-derived measurements in HD management.

22 July 2025 in Ophthalmology Retina
Verified
Journal Article
Closed access
PWPeter J. Weng
Peter J. Weng
RWRichmond Woodward
Richmond Woodward
WDWalter Duy
Walter Duy
GGGabriel Gomide
Gabriel Gomide
AAAhmed Alshaikhsalama
Ahmed Alshaikhsalama
SFSharon Fekrat
Sharon Fekrat

3 August 2026 in Ophthalmology
Verified
Journal Article
Open access
AAAhmed Abdi
Ahmed Abdi
AAAhmed Alshaikhsalama
Ahmed Alshaikhsalama
ZZZuhair Zaidi
Zuhair Zaidi
AAAmer F. Alsoudi
Amer F. Alsoudi
MYMelissa Yuan
Melissa Yuan
EREhsan Rahimy
Ehsan Rahimy