Daniel Formariz Legendre

Dr. Daniel Formariz Legendre

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2024 in Microorganisms
Verified
Journal Article
Open access
PDF file
DSDiego Morais da Silva
Diego Morais da Silva
FNFellype do Nascimento
Fellype do Nascimento
NMNoala Vicensoto Moreira Milhan
Noala Vicensoto Moreira Milhan
MOMaria Oliveira
Maria Oliveira
PCPaulo Francisco Guerreiro Cardoso
Paulo Francisco Guerreiro Cardoso
CKCristiane Koga-Ito
Cristiane Koga-Ito
Despite the excellent properties of silicone endotracheal prostheses, their main limitation is the formation of a polymicrobial biofilm on their surfaces. It can cause local inflammation, interfering with the local healing process and leading to further complications in the clinical scenario. The present study evaluated the inhibitory effect of cold atmospheric plasma (CAP) on multispecies biofilms grown on the silicone protheses’ surfaces. In addition to silicone characterization before and after CAP exposure, CAP cytotoxicity on immortalized human bronchial epithelium cell line (BEAS-2B) was evaluated. The aging time test reported that CAP could temporarily change the silicone surface wetting characteristics from hydrophilic (80.5°) to highly hydrophilic (<5°). ATR-FTIR showed no significant alterations in the silicone surficial chemical composition after CAP exposure for 5 min. A significant log reduction in viable cells in monospecies biofilms (log CFU/mL) of C. albicans, S. aureus, and P. aeruginosa (0.636, 0.738, and 1.445, respectively) was detected after CAP exposure. Multispecies biofilms exposed to CAP showed significant viability reduction for C. albicans and S. aureus (1.385 and 0.831, respectively). The protocol was not cytotoxic to BEAS-2B. CAP can be a simple and effective method to delay multispecies biofilm formation inside the endotracheal prosthesis.

7 March 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
AGAline Grein-Iankovski
Aline Grein-Iankovski
KOKarina Andrighetti Oliveira-Braga
Karina Andrighetti Oliveira-Braga
DLDaniel Formariz Legendre
Daniel Formariz Legendre
PCPaulo Francisco Guerreiro Cardoso
Paulo Francisco Guerreiro Cardoso
WLWatson Loh
Watson Loh
Cilia are biological structures essential to drive the mobility of secretions and maintain the proper function of the respiratory airways. However, this motile self-cleaning process is significantly compromised in the presence of silicone tracheal prosthesis, leading to biofilm growth and impeding effective treatment. To address this challenge and enhance the performance of these devices, we propose the fabrication of magnetic silicone cilia, with the prospect of their integration onto silicone prostheses. The present study presents a fabrication method based on magnetic self-assembly and assesses the interaction behavior of the cilia array with biological mucus. This protocol allows for the customization of cilia dimensions across a wide range of aspect ratios (from 6 to 85) and array densities (from 10 to 80 cilia/mm2) by adjusting the fabrication parameters, offering flexibility for adjustments according to their required characteristics. Furthermore, we evaluated the suitability of different cilia arrays for biomedical applications by analyzing their interaction with bullfrog mucus, simulating the airways environment. Our findings demonstrate that the fabricated cilia are mechanically resistant to the viscous fluid and still exhibit controlled movement under the influence of an external moving magnet. A correlation between cilia dimensions and mucus wettability profile suggests a potential role in facilitating mucus depuration, paving the way for further advancements aimed at enhancing the performance of silicone prostheses in clinical settings.

20 November 2024 in Polymers
Verified
Journal Article
Open access
PDF file
KKKonstantin Georgiev Kostov
Konstantin Georgiev Kostov
ABAnanias Alves Barbosa
Ananias Alves Barbosa
FNFellype do Nascimento
Fellype do Nascimento
PCPaulo Francisco Guerreiro Cardoso
Paulo Francisco Guerreiro Cardoso
AAAna Carla Paula Leite Almeida
Ana Carla Paula Leite Almeida
CKCristiane Koga-Ito
Cristiane Koga-Ito
Tracheal stenosis (i.e., the abnormal narrowing of the trachea) can occur due to a variety of inflammatory and infectious processes as well as due to therapeutic procedures undertaken by the patient. The most common cause of tracheal obstruction in patients has been prolonged intubation. Depending on the extent of the stenosis and its exact location, the surgical insertion of a tracheal stent is the only option for addressing this issue. The Montgomery T-tube implant is a valuable tracheal stent made from medical-grade silicone that provides a functional airway while supporting the tracheal mucosa. However, its performance is subject to gradual deterioration due to biofilm colonization of the stent’s inner wall, which may explain the discomfort claimed by many patients and clinical failures. Recently, cold atmospheric plasmas (CAPs) have emerged as an alternative technology to many conventional medical procedures, such as wound healing, skin treatment, decontamination of medical devices, etc. Here, we report on plasma-induced surface modification of the inner wall of a T-tube implant, considering future biomedical applications. To generate the plasma, we employed a cold atmospheric pressure plasma jet in gas helium, which was directly inserted into the T-tube implant. To assess the treatment uniformity, the degree of surface modification and its extension along the stent’s inner wall was analyzed using different process parameters.

17 December 2023
Verified
Book Chapter
Closed access
PDF file
DLDaniel Formariz Legendre
Daniel Formariz Legendre
GLGustavo Sensaki Lucente
Gustavo Sensaki Lucente
VUVinicius Ruiz Uemoto
Vinicius Ruiz Uemoto
HMHelio Minamoto
Helio Minamoto
CKCristiane Koga-Ito
Cristiane Koga-Ito
FAFabio Aoki
Fabio Aoki