Mozziyar Etemadi

Dr. Mozziyar Etemadi

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2019 in Nature Medicine
Verified
Journal Article
Closed access
PDF file
DADiego Ardila
Diego Ardila
AKAtilla P. Kiraly
Atilla P. Kiraly
SBSujeeth Bharadwaj
Sujeeth Bharadwaj
BCBokyung Choi
Bokyung Choi
JRJoshua J. Reicher
Joshua J. Reicher
SSShravya Shetty
Shravya Shetty

31 May 2022 in JMIR Medical Informatics
Verified
Journal Article
Open access
JHJonathan Huang
Jonathan Huang
GGGalal Galal
Galal Galal
MEMozziyar Etemadi
Mozziyar Etemadi
MVMahesh Vaidyanathan
Mahesh Vaidyanathan
Background: Racial bias is a key concern regarding the development, validation, and implementation of machine learning (ML) models in clinical settings. Despite the potential of bias to propagate health disparities, racial bias in clinical ML has yet to be thoroughly examined and best practices for bias mitigation remain unclear. Objective: Our objective was to perform a scoping review to characterize the methods by which the racial bias of ML has been assessed and describe strategies that may be used to enhance algorithmic fairness in clinical ML. Methods: A scoping review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) Extension for Scoping Reviews. A literature search using PubMed, Scopus, and Embase databases, as well as Google Scholar, identified 635 records, of which 12 studies were included. Results: Applications of ML were varied and involved diagnosis, outcome prediction, and clinical score prediction performed on data sets including images, diagnostic studies, clinical text, and clinical variables. Of the 12 studies, 1 (8%) described a model in routine clinical use, 2 (17%) examined prospectively validated clinical models, and the remaining 9 (75%) described internally validated models. In addition, 8 (67%) studies concluded that racial bias was present, 2 (17%) concluded that it was not, and 2 (17%) assessed the implementation of bias mitigation strategies without comparison to a baseline model. Fairness metrics used to assess algorithmic racial bias were inconsistent. The most commonly observed metrics were equal opportunity difference (5/12, 42%), accuracy (4/12, 25%), and disparate impact (2/12, 17%). All 8 (67%) studies that implemented methods for mitigation of racial bias successfully increased fairness, as measured by the authors’ chosen metrics. Preprocessing methods of bias mitigation were most commonly used across all studies that implemented them. Conclusions: The broad scope of medical ML applications and potential patient harms demand an increased emphasis on evaluation and mitigation of racial bias in clinical ML. However, the adoption of algorithmic fairness principles in medicine remains inconsistent and is limited by poor data availability and ML model reporting. We recommend that researchers and journal editors emphasize standardized reporting and data availability in medical ML studies to improve transparency and facilitate evaluation for racial bias.

3 June 2021 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
VGVenu G. Ganti
Venu G. Ganti
ACAndrew M. Carek
Andrew M. Carek
BNBrandi N. Nevius
Brandi N. Nevius
JHJ. Alex Heller
J. Alex Heller
MEMozziyar Etemadi
Mozziyar Etemadi
OIOmer Inan
Omer Inan
Objective: We developed a wearable watch-based device to provide noninvasive, cuff-less blood pressure (BP) estimation in an at-home setting. Methods: The watch measures single-lead electrocardiogram (ECG), tri-axial seismocardiogram (SCG), and multi-wavelength photoplethysmogram (PPG) signals to compute the pulse transit time (PTT), allowing for BP estimation. We sent our custom watch device and an oscillometric BP cuff home with 21 healthy subjects, and captured the natural variability in BP over the course of a 24-hour period. Results: After calibration, our Pearson correlation coefficient (PCC) of 0.69 and root-mean-square-error (RMSE) of 2.72 mmHg suggest that noninvasive PTT measurements correlate with around-the-clock BP. Using a novel two-point calibration method, we achieved a RMSE of 3.86 mmHg. We further demonstrated the potential of a semi-globalized adaptive model to reduce calibration requirements. Conclusion: This is, to the best of our knowledge, the first time that BP has been comprehensively estimated noninvasively using PTT in an at-home setting. We showed a more convenient method for obtaining ambulatory BP than through the use of the standard oscillometric cuff. We presented new calibration methods for BP estimation using fewer calibration points that are more practical for a real-world scenario. Significance: A custom watch (SeismoWatch) capable of taking multiple BP measurements enables reliable remote monitoring of daily BP and paves the way towards convenient hypertension screening and management, which can potentially reduce hospitalizations and improve quality of life.

1 November 2022 in Radiology
Verified
Journal Article
Closed access
ASAndrew B. Sellergren
Andrew B. Sellergren
CCChristina Chen
Christina Chen
ZNZaid Nabulsi
Zaid Nabulsi
YLYuanzhen Li
Yuanzhen Li
AMAaron Maschinot
Aaron Maschinot
SSShravya Shetty
Shravya Shetty
This method enabled prediction performance comparable to state-of-the-art deep learning models in multiple clinical tasks by using as few as 45 chest radiographs. Background Developing deep learning models for radiology requires large data sets and substantial computational resources. Data set size limitations can be further exacerbated by distribution shift...

1 February 2018 in Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
MEMozziyar Etemadi
Mozziyar Etemadi
OIOmer T. Inan
Omer T. Inan
Cardiovascular diseases (CVDs) are prevalent in the US, and many forms of CVD primarily affect the mechanical aspects of heart function. Wearable technologies for monitoring the mechanical health of the heart and vasculature could enable proactive management of CVDs through titration of care based on physiological status as well as preventative wellness monitoring to help promote lifestyle choices that reduce the overall risk of developing CVDs. Additionally, such wearable technologies could be used to optimize human performance in austere environments. This review describes our progress in developing wearable ballistocardiogram (BCG)- and seismocardiogram-based systems for monitoring relative changes in cardiac output, contractility, and blood pressure. Our systems use miniature, low-noise accelerometers to measure the movements of the body in response to the heartbeat and novel machine learning algorithms to provide robustness against motion artifacts and sensor misplacement. Moreover, we have mathematically related wearable BCG signals—representing local, cardiogenic movements of a point on the body—to better understood whole body BCG signals, and thereby improved estimation of key health parameters. We validated these systems with experiments in healthy subjects, studies in patients with heart failure, and measurements in austere environments such as water immersion. The systems can be used in future work as a tool for clinicians and physiologists to measure the mechanical aspects of cardiovascular function outside of clinical settings, and to thereby titrate care for patients with CVDs, provide preventative screening, and optimize performance in austere environments by providing real-time in-depth information regarding performance and risk.

31 January 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
MSMobashir Hasan Shandhi
Mobashir Hasan Shandhi
JFJoanna Fan
Joanna Fan
JHJ. Alex Heller
J. Alex Heller
MEMozziyar Etemadi
Mozziyar Etemadi
LKLiviu Klein
Liviu Klein
OIOmer Inan
Omer Inan
Objective: Tracking changes in hemodynamic congestion and the consequent proactive readjustment of treatment has shown efficacy in reducing hospitalizations for patients with heart failure (HF). However, the cost-prohibitive nature of these invasive sensing systems precludes their usage in the large patient population affected by HF. The objective of this research is to estimate the changes in pulmonary artery mean pressure (PAM) and pulmonary capillary wedge pressure (PCWP) following vasodilator infusion during right heart catheterization (RHC), using changes in simultaneously recorded wearable seismocardiogram (SCG) signals captured with a small wearable patch. Methods: A total of 20 patients with HF (20% women, median age 55 (interquartile range (IQR), 44-64) years, ejection fraction 24 (IQR, 16-43)) were fitted with a wearable sensing patch and underwent RHC with vasodilator challenge. We divided the dataset randomly into a training–testing set ( n = 15) and a separate validation set ( n = 5). We developed globalized (population) regression models to estimate changes in PAM and PCWP from the changes in simultaneously recorded SCG. Results: The regression model estimated both pressures with good accuracies: root-mean-square-error (RMSE) of 2.5 mmHg and R 2 of 0.83 for estimating changes in PAM, and RMSE of 1.9 mmHg and R 2 of 0.93 for estimating changes in PCWP for the training-testing set, and RMSE of 2.7 mmHg and R 2 of 0.81 for estimating changes in PAM, and RMSE of 2.9 mmHg and R 2 of 0.95 for estimating changes in PCWP for the validation set respectively. Conclusion: Changes in wearable SCG signals may be used to track acute changes in intracardiac hemodynamics in patients with HF. Significance: This method holds promise in tracking longitudinal changes in hemodynamic congestion in hemodynamically-guided remote home monitoring and treatment for patients with HF.