Hui Zhao

Mr. Hui Zhao

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2017 in Journal of the European Ceramic Society
Verified
Journal Article
Closed access
HZHui Zhao
Hui Zhao
Litong ZhangLitong Zhang
Litong Zhang
BCBo Chen
Bo Chen
ZHZongbei He
Zongbei He
JZJiaxin Zhang
Jiaxin Zhang
YLYongsheng Liu
Yongsheng Liu

1 December 2019 in Journal of the European Ceramic Society
Verified
Journal Article
Closed access
JZJiaxin Zhang
Jiaxin Zhang
YLYongsheng Liu
Yongsheng Liu
LCLaifei Cheng
Laifei Cheng
HZHui Zhao
Hui Zhao
JWJing Wang
Jing Wang
LZLitong Zhang
Litong Zhang

8 October 2019 in Journal of Wuhan University of Technology-Mater. Sci. Ed.
Verified
Journal Article
Closed access
PDF file
HZHui Zhao
Hui Zhao
LZLitong Zhang
Litong Zhang
BCBo Chen
Bo Chen
JZJiaxin Zhang
Jiaxin Zhang

1 February 2023 in Materials Research Express
Verified
Journal Article
Open access
HZHui Zhao
Hui Zhao
JZJiaxin Zhang
Jiaxin Zhang
In this research, a novel method of CVI + RMI 3DN C/SiC torque tube preparation has been researched. CVI + RMI 3DN C/SiC flat panel was evaluated by Archimedes drainage method for density and open porosity, SEM for morphological characterization, XRD for phase composition characterization, and chemical method for composition mass and volume content. It has an average density of 2.19 g cm−3, and open porosity of 10%. The computed chemical composition method findings are undoubtedly in line with the fiber design volume percentage of 30%. Tensile and shear mechanical tests on 3DN C/SiC standard sample were investigated, with good performance. The average tensile and shear strength was 141.64 MPa and 86.24 MPa respectively. 3DN C/SiC torque tubes were prepared by the same process, and the torsional mechanical tests were carried out. According to the mechanical parameters of the flat panel 3DN C/SiC sample, the mechanical properties of stress distribution and shear stress-strain curves for the torque tube are predicted by using the finite element simulation method, which is in good agreement with the test results. The test and simulation error of the maximum shear strength is only about 2%.

20 June 2023 in Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications
Verified
Journal Article
Closed access
HZHui Zhao
Hui Zhao
JZJiaxin Zhang
Jiaxin Zhang
To overcome the inherent limitations of the ceramic matrix composite (CMC) process and increase the torque capacity of CMC torque tubes, this study investigated the failure causes of 2D woven chemical vapor infiltration (CVI) C/SiC and SiC/SiC combined CMC torque tubes. The CT test was used to describe the non-homogeneous density distribution of the CMC torque tubes. Using the Archimedes drainage method to evaluate density and porosity, we simulated the stress distribution and failure strength of CMC torque tubes using an FEM model. Fixtures suitable for universal material testing apparatuses were used for CMC torque tube torsional tests. The stress-strain curves showed that two distinct fiber types of CMC torque tubes displayed different torsional tendencies, and we examined the main causes of failure. The SiC fiber in the CMC torque tube increased maximum shear stress and modulus. Additionally, the strength of the SiC/SiC torque tube, rather than the interface between the C/SiC and SiC/SiC torque tubes, was the primary cause of combined CMC torque tube failure.

29 October 2026 in International Journal of Applied Ceramic Technology
Verified
Journal Article
Closed access
JSJie Su
Jie Su
JLJianxia Liu
Jianxia Liu
JZJiaxin Zhang
Jiaxin Zhang
JZJinghe Zheng
Jinghe Zheng
HZHui Zhao
Hui Zhao
YZYi Zhang
Yi Zhang