Evaluation and prediction of wear play a key role in product design and material selection of total hip replacements, because wear debris is one of the main causes of loosening and failure. Multifactorial clinical or laboratory studies are high cost and require unfeasible timeframes for implant development. Simulation using finite element methods is an efficient and inexpensive alternative to predict wear and pre-screen various parameters. This article presents a comprehensive literature review of the state-of-the-art finite element modelling techniques that have been applied to evaluate wear in polyethylene hip replacement components. A number of knowledge gaps are identified including the need to develop appropriate wear coefficients and the analysis of daily living activities.
After hip replacement, in cases where there is instability at the joint, contact between the femoral head and the acetabular liner can move from the bearing surface to the liner rim, generating edge loading conditions. This has been linked to polyethylene liner fracture and led to the development of a regulatory testing standard (ISO 14242:4) to replicate these conditions. Performing computational modelling alongside simulator testing can provide insight into the complex damage mechanisms present in hard-on-soft bearings under edge loading. The aim of this work was to evaluate the need for inertia and elastoplastic material properties to predict kinematics (likelihood of edge loading) and plastic strain accumulation (as a damage indicator). While a static, rigid model was sufficient to predict kinematics for experimental test planning, the inclusion of inertia, alongside elastoplastic material, was required for prediction of plastic strain behaviour. The delay in device realignment during heel strike, caused by inertia, substantially increased the force experienced during rim loading (e.g. 600 N static rigid, ∼1800 N dynamic elastoplastic, in one case). The accumulation of plastic strain is influenced by factors including cup orientation, swing phase force balance, the moving mass, and the design of the device itself. Evaluation of future liner designs could employ dynamic elastoplastic models to investigate the effect of design feature changes on bearing resilience under edge loading.
Patient imaging and explant analysis has shown evidence of edge loading of hard-on-hard hip replacements in vivo. Experimental hip simulator testing under edge loading conditions has produced increased, clinically-relevant, wear rates for hard-on-hard bearings when compared to concentric conditions. Such testing, however, is time consuming and costly. A quick running computational edge loading model (Python Edge Loading (PyEL) - quasi-static, rigid, frictionless), capable of considering realistic bearing geometries, was developed. The aim of this study was to produce predictions of separation within the typical experimental measurement error of ∼0.5 mm. The model was verified and validated against comparable finite element (FE) models (including inertia and friction) and pre-existing experimental test data for 56 cases, covering a variety of simulated cup orientations, positions, tissue tensions, and loading environments. The PyEL model agreed well with both the more complex computational modelling and experimental results. From comparison with the FE models, the assumption of no inertia had little effect on the maximum separation prediction. With high contact force cases, the assumption of no friction had a larger effect (up to ∼5% error). The PyEL model was able to predict the experimental maximum separations within ∼0.3 mm. It could therefore be used to optimise an experimental test plan and efficiently investigate a much wider range of scenarios and variables. It could also help explain trends and damage modes seen in experimental testing through identifying the contact locations on the liner that are not easily measured experimentally.