Alison Jones

Dr. Alison Jones

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 May 2007 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
AJAlison Jones
Alison Jones
RWRuth K Wilcox
Ruth K Wilcox
This study aimed to establish model construction and configuration procedures for future vertebral finite element analysis by studying convergence, sensitivity, and accuracy behaviors of semiautomatically generated models and comparing the results with manually generated models. During a previous study, six porcine vertebral bodies were imaged using a microcomputed tomography scanner and tested in axial compression to establish their stiffness and failure strength. Finite element models were built using a manual meshing method. In this study, the experimental agreement of those models was compared with that of semiautomatically generated models of the same six vertebrae. Both manually and semiautomatically generated models were assigned gray-scale-based, element-specific material properties. The convergence of the semiautomatically generated models was analyzed for the complete models along with material property and architecture control cases. A sensitivity study was also undertaken to test the reaction of the models to changes in material property values, architecture, and boundary conditions. In control cases, the element-specific material properties reduce the convergence of the models in comparison to homogeneous models. However, the full vertebral models showed strong convergence characteristics. The sensitivity study revealed a significant reaction to changes in architecture, boundary conditions, and load position, while the sensitivity to changes in material property values was proportional. The semiautomatically generated models produced stiffness and strength predictions of similar accuracy to the manually generated models with much shorter image segmentation and meshing times. Semiautomatic methods can provide a more rapid alternative to manual mesh generation techniques and produce vertebral models of similar accuracy. The representation of the boundary conditions, load position, and surrounding environment is crucial to the accurate prediction of the vertebral response. At present, an element size of 2×2×2mm3 appears sufficient since the error at this size is dominated by factors, such as the load position, which will not be improved by increasing the mesh resolution. Higher resolution meshes may be appropriate in the future as models are made more sophisticated and computational processing time is reduced.

12 August 2021 in Medical Engineering & Physics
Verified
Journal Article
Open access
FJFaezeh Jahani
Faezeh Jahani
LELee W. Etchels
Lee W. Etchels
LWLin Wang
Lin Wang
JTJonathan Thompson
Jonathan Thompson
David Charles BartonDavid Charles Barton
David Charles Barton
AJAlison Jones
Alison Jones
After hip replacement, in cases where there is instability at the joint, contact between the femoral head and the acetabular liner can move from the bearing surface to the liner rim, generating edge loading conditions. This has been linked to polyethylene liner fracture and led to the development of a regulatory testing standard (ISO 14242:4) to replicate these conditions. Performing computational modelling alongside simulator testing can provide insight into the complex damage mechanisms present in hard-on-soft bearings under edge loading. The aim of this work was to evaluate the need for inertia and elastoplastic material properties to predict kinematics (likelihood of edge loading) and plastic strain accumulation (as a damage indicator). While a static, rigid model was sufficient to predict kinematics for experimental test planning, the inclusion of inertia, alongside elastoplastic material, was required for prediction of plastic strain behaviour. The delay in device realignment during heel strike, caused by inertia, substantially increased the force experienced during rim loading (e.g. 600 N static rigid, ∼1800 N dynamic elastoplastic, in one case). The accumulation of plastic strain is influenced by factors including cup orientation, swing phase force balance, the moving mass, and the design of the device itself. Evaluation of future liner designs could employ dynamic elastoplastic models to investigate the effect of design feature changes on bearing resilience under edge loading.

5 April 2017 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
RCRobert J. Cooper
Robert J. Cooper
MMMarlène Mengoni
Marlène Mengoni
DGDawn Groves
Dawn Groves
SWSophie Williams
Sophie Williams
MBMarcus J.K. Bankes
Marcus J.K. Bankes
AJAlison Jones
Alison Jones
Abnormal bony morphology is a factor implicated in hip joint soft tissue damage and an increased lifetime risk of osteoarthritis. Standard 2‐dimensional radiographic measurements for diagnosis of hip deformities, such as cam deformities on the femoral neck, do not capture the full joint geometry and are not indicative of symptomatic damage.In this study, a 3‐dimensional geometric parameterisation system was developed to capture key variations in the femur and acetabulum of subjects with clinically diagnosed cam deformity. The parameterisation was performed for computed tomography scans of 20 patients (10 female and 10 male). Novel quantitative measures of cam deformity were taken and used to assess differences in morphological deformities between males and females.The parametric surfaces matched the more detailed, segmented hip bone geometry with low fitting error. The quantitative severity measures captured both the size and the position of cams and distinguished between cam and control femurs. The precision of the measures was sufficient to identify differences between subjects that could not be seen with the sole use of 2‐dimensional imaging. In particular, cams were found to be more superiorly located in males than in females.As well as providing a means to distinguish between subjects more clearly, the new geometric hip parameterisation facilitates the flexible and rapid generation of a range of realistic hip geometries including cams. When combined with material property models, these stratified cam shapes can be used for further assessment of the effect of the geometric variation under impingement conditions.

16 July 2025 in Bone & Joint Research
Verified
Journal Article
Open access
PDF file
BDBernard H. van Duren
Bernard H. van Duren
MTMohamad Taufiqurrakhman
Mohamad Taufiqurrakhman
AJAlison Jones
Alison Jones
MHMark Higgins
Mark Higgins
AMAndrew R. Manktelow
Andrew R. Manktelow
HPHemant G. Pandit
Hemant G. Pandit
Aims: Cemented polished taper fit (PTF) stems are the femoral implant of choice for total hip arthroplasty (THA) in many locations worldwide. There is increasing evidence that periprosthetic fracture may be the single major contributor to reoperation with these stems. The aim of this study was to demonstrate how mismatches at the implant-cement interface may occur and the subsequent effect of these incongruities on the contacting area and the forces transmitted to the cement mantle.Methods: A parametric equation-based model was developed to determine the contact mismatch relative to axial stem rotations. This model was also used to calculate the restoration of contact surface area with stem subsidence for both a dual-taper and triple-taper geometry. A finite element analysis (FEA) was used to compare the effects of reduced contact area due to the incongruent hip implant-cement interface.Results: The contact model showed a large decrease in surface contact area with even only a small rotation going from 100% at 0° to 50.00% at 2.5° for the dual-taper geometry, and from 100% at 0° to 50.20% at 2.5° for the triple-taper geometry. There was a gradual but small ongoing decrease in contact surface with increasing rotation for both the dual-taper and triple-taper geometries. For both taper designs, there was an increase in contact surface area with an increase in subsidence resulting in contact for up to a 5° mismatch being restored with 2 mm subsidence. FEA showed that with increasing mismatches and consequent contact area reduction, there was an increase in von Mises stress in the implant-cement interface of up to 235%.Conclusion: With increasing mismatch, there was an increase in maximum stresses, total strain, and subsidence in the cement mantle, highlighting the importance of achieving an optimal implant-cement interface at the time of implantation of cemented PTF femoral stems.Cite this article: Bone Joint Res 2025;14(7):642–655.

1 February 2023 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
AJAlison Jones
Alison Jones
TSTodd D. Stewart
Todd D. Stewart
NMNiall Msc Maher
Niall Msc Maher
CHColin FRCS Holton
Colin FRCS Holton
Background: The Warwick consensus defined femoroacetabular impingement syndrome as a motion-related clinical disorder of the hip with a triad of symptoms, clinical signs, and imaging findings representing symptomatic premature contact between the proximal femur and acetabulum. Several factors appear to cause labral and cartilage damage, including joint shape and orientation and patient activities. There is a lack of tools to predict impingement patterns in a patient across activities. Current computational modeling tools either measure pure ROM of the joint or include complexity that reduces reliability and increases time to achieve a solution. Questions/purposes: The purpose of this study was to examine the efficacy of a low computational cost approach to combining cam-type hip shape and multiple hip motions for predicting impingement. Specifically, we sought to determine (1) the potential to distinguish impingement in individual hip shapes by analyzing the difference between a cam lesion at the anterior femoral neck and one located at the superior femoral neck; (2) sensitivity to three aspects of hip alignment, namely femoral neck-shaft angle, femoral version angle, and pelvic tilt; and (3) the difference in impingement measures between the individual activities in our hip motion dataset. Methods: A model of the shape and alignment of a cam-type impinging hip was created and used to describe two locations of a cam lesion on the femoral head-neck junction (superior and anterior) based on joint shape information available in prior studies. Sensitivity to hip alignment was assessed by varying three aspects from a baseline (typical alignment described in prior studies), namely, femoral neck-shaft angle, femoral version, and pelvic tilt. Hip movements were selected from an existing database of 18 volunteers performing 13 activities (10 male, eight female; mean age 44 ± 19 years). A subset was selected to maximize variation in the range of joint angles and maintain a consistent number of people performing each activity, which resulted in nine people per activity, including at least three of each sex. Activities included pivoting during walking, squatting, and golf swing. All selected hip motion cases were applied to each hip shape model. For the first part of the study, the number of motion cases in which impingement was predicted was recorded. Quantitative analyses of the depth of penetration of the cam lesion into the acetabular socket and qualitative observations of impingement location were made for each lesion location (anterior and superior). In the second part of the study, in which we aimed to test the sensitivity of the findings to hip joint orientation, full analysis of both cam lesion locations was repeated for three modified joint orientations. Finally, the results from the first part of the analysis were divided by activity to understand how the composition of the activity dataset affected the results. Results: The two locations of cam lesion generated impingement in a different percentage of motion cases (anterior cam: 56% of motion cases; superior cam: 13% of motion cases) and different areas of impingement in the acetabulum, but there were qualitatively similar penetration depths (anterior cam: 6.8° ± 5.4°; superior cam: 7.9° ± 5.8°). The most substantial effects of changing the joint orientation were a lower femoral version angle for the anterior cam, which increased the percentage of motion cases generating impingement to 67%, and lower neck-shaft angle for the superior cam, which increased the percentage of motion cases generating impingement to 37%. Flexion-dominated activities (for example, squatting) only generated impingement with the anterior cam. The superior cam generated impingement during activities with high internal-external rotation of the joint (for example, the golf swing). Conclusion: This work demonstrated the capability of a simple, rapid computational tool to assess impingement of a specific cam-type hip shape (under 5 minutes for more than 100 motion cases). To our knowledge, this study is the first to do so for a large set of motion cases representing a range of activities affecting the hip, and could be used in planning surgical bone removal. Clinical Relevance: The results of this study imply that patients with femoroacetabular impingement syndrome with cam lesions on the superior femoral head-neck junction may experience impinging during motions that are not strongly represented by current physical diagnostic tests. The use of this tool for surgical planning will require streamlined patient-specific hip shape extraction from imaging, model sensitivity testing, evaluation of the hip activity database, and validation of impingement predictions at an individual patient level.

9 January 2025 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Open access
RCRobert J Cooper
Robert J Cooper
GDGavin A Day
Gavin A Day
VWVithanage N Wijayathunga
Vithanage N Wijayathunga
JYJiacheng Yao
Jiacheng Yao
MMMarlène Mengoni
Marlène Mengoni
AJAlison Jones
Alison Jones
Subject-specific finite element models of knee joint contact mechanics are used in assessment of interventions and disease states. Cartilage thickness distribution is one factor influencing the distribution of pressure. Precision of cartilage geometry capture varies between imaging protocols. This work evaluated the cartilage thickness distribution precision needed for contact mechanics prediction in models of the tibiofemoral joint by comparing model outputs to experimental measurements for three cadaveric specimens. Models with location-specific cartilage thickness were compared to those with a uniform thickness, for a fixed relative orientation of the femur and tibia and with tibial freedom of movement. Under constrained conditions, the advantage of including location-specific cartilage thickness was clear. Models with location-specific thickness predicted the proportion of force through each condyle with an average error of 5% (compared to 27% with uniform thickness) and predicted the experimental contact area with an error of 21 mm 2 (compared to 98 mm 2 with uniform thickness). With tibial freedom, the advantage of location-specific cartilage thickness not clear. The attempt to allow three degrees of relative freedom at the tibiofemoral joint resulted in a high degree of experimental and computational uncertainty. It is therefore recommended that researchers avoid this level of freedom. This work provides some evidence that highly constrained conditions make tibiofemoral contact mechanics predictions more sensitive to cartilage thickness and should perhaps be avoided in studies where the means to generate subject-specific cartilage thickness are not available.