Background: APOBEC3-mediated cytidine deamination produces G→A substitutions in HIV genomes, described in proviral DNA but detectable in plasma HIV-1 RNA using NGS. APOBEC-signature mutations reflect G→A enrichment substitutions, whereas APOBEC-context mutations are substitutions at drug resistance-associated positions compatible with APOBEC editing. We evaluated theirprevalence and impact on resistance interpretation. Methods: We retrospectively analysed plasma HIV-1 NGS-sequences from antiretroviral-naive individuals in 2022–2023. Sequencing was performed in participating laboratories, and FASTQ centrally reanalyzed using DeepChek. APOBEC-signature mutations, APOBEC-context drug resistance mutations (DRMs), and stop codons were assessed in protease, reverse transcriptase, and integrase at 1%, 3%, and 5% thesholds. Results: Among 290 individuals, 268 had complete NGS. At 1%, APOBEC-signature mutations were detected in 159 individuals and APOBEC-context DRMs in 64 (22%). Both patterns coexisted in 52 (18%), decreasing to 17 (6%) and 8 (3%) at 3% and 5% thresholds. Certain mutations, including M184I, G190E, G140S, and R263K, remained detectable at higher thresholds. R263K co-occurred with multiple APOBEC-signature mutations and stop codons indicating extensive APOBEC-mediated editing. Conclusions: APOBEC-associated mutations are detectable in plasma HIV-1 RNA and may affect resistance interpretation. Conservative frequency thresholds (5%) APOBEC-signatures evaluation may reduce misclassification of APOBEC-induced variants as clinically relevant resistance.
Precise HDV-RNA detection and quantification are pivotal for accurate diagnosis and monitoring of response to newly approved treatment. We evaluate the performance of three assays: Hepatitis Delta RT-PCR system, EurobioPlex HDV assay, and the RoboGene HDV RNA Quantification kit 2.0, testing 151 HBsAg-positive samples, 90 HDV-RNA negative and 61 HDV-RNA positive. We also evaluated serial dilutions of the WHO international standard for HDV, PEI 7657/12. Finally, all HDV-RNA positive samples were genotyped using a next-generation sequencing strategy. Qualitative results indicated a 100% concordance between tests. Quantitative results correlated well between tests, r2=0.703 (Vircell-vs-Eurobio), r2=0.833 (Vircell-vs-RoboGene), r2=0.835 (Robogene-vs-Eurobio). Bias index was 2.083 (Vircell-vs-Eurobio), -1.283 (Vircell-vs-RoboGene), and -3.36 (Robogene-vs-Eurobio). Using the WHO IS, Vircell overestimated the viral load by 0.98 log IU/mL, Eurobio by 1.46 log IU/mL, and RoboGene underestimated it by 0.98 log IU/mL. Fifty-nine samples were successfully genotyped (Genotype 1, n=52; Genotype 5, n=7; Genotype 6, n=1), with similar results in terms of correlation and bias. The three assays demonstrate promising performance. Their accuracy, reflected in concordance rates and quantitative analysis, makes them suitable for clinical practice. However, in the absence of assay harmonization, quantitative HDV RNA monitoring should be performed in the same laboratory and assay to avoid variability.