Kamil Lipiński

Mr. Kamil Lipiński

Politechnika Warszawska, Warsaw, Mazowieckie, Poland
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
KLKamil Lipiński
Kamil Lipiński
PBPiotr Bogorodzki
Piotr Bogorodzki
Intravoxel Incoherent Motion (IVIM) imaging provides non-invasive perfusion measurements, eliminating the need for contrast agents. This work explores the feasibility of IVIM imaging in whole brain perfusion studies, where an isotropic 1 mm voxel is widely accepted as a standard. This study follows the validity of a time-limited, precise, segmentation-ready whole-brain IVIM protocol suitable for clinical reality. To assess the influence of SNR on the estimation of S0, f, D*, and D IVIM parameters, a series of measurements and simulations were performed in MATLAB for the following three estimation techniques: segmented grid search, segmented curve fitting, and one-step curve fitting, utilizing known “ground truth” and noised data. Scanner-specific SNR was estimated based on a healthy subject IVIM MRI study in a 3T scanner. Measurements were conducted for 25.6 × 25.6 × 14.4 cm FOV with a 256 × 256 in-plane resolution and 72 slices, resulting in 1 × 1 × 2 mm voxel size. Simulations were performed for 36 SNR levels around the measured SNR value. For a single voxel grid, the search algorithm mean relative error Ŝ0, f^, D^*, and D^ of at the expected SNR level were 5.00%, 81.91%, 76.31%, and 18.34%, respectively. Analysis has shown that high-resolution IVIM imaging is possible, although there is significant variation in both accuracy and precision, depending on SNR and the chosen estimation method.

19 February 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
KLKamil Lipiński
Kamil Lipiński
PBPiotr Bogorodzki
Piotr Bogorodzki
Intra Voxel Incoherent Motion (IVIM) imaging provides non-invasive perfusion measurements, eliminating the need for contrast agents. The aim of this work was to explore the feasibility of IVIM in whole brain perfusion studies, where isotropic 1mm voxel is widely accepted as a standard. This study treats on validity of time limited, precise, segmentation ready Whole Brain IVIM imaging protocol suitable for clinical reality. To assess the influence of SNR on the estimation of S0, f, D* and D IVIM parameters a series of measurements and simulations under MATLAB environment were performed for three estimation techniques, utilizing known “ground truth” and noised data. Scanner specific SNR was estimated based on healthy subject IVIM MRI study in 3T scanner. Measurements were conducted for 25,6x25,6x14,4 cm FOV with 256x256 in plane resolution and 72 slices resulting in 1x1x2 mm voxel size. Simulations were performed for 36 SNR levels around measured SNR value. Single voxel grid search estimation method mean relative error for S0 f D* D estimates at measured SNR level were: 5.00%,81.91%, 76.31%, 18.34% respectively. Analysis has shown that high resolution IVIM is possible, although there is significant variation in estimation accuracy and precision depending on SNR level and chosen estimation method.

4 April 2025 in Psychiatry Research: Neuroimaging
Verified
Journal Article
Closed access
PPPiotr Podwalski
Piotr Podwalski
BDBartosz Dawidowski
Bartosz Dawidowski
KLKamil Lipiński
Kamil Lipiński
ŁFŁukasz Franczak
Łukasz Franczak
PWPatryk Wysocki
Patryk Wysocki
JSJerzy Samochowiec
Jerzy Samochowiec

Verified
Journal Article
Open access
PDF file
PWPrzemysław Wróblewski
Przemysław Wróblewski
MWMichał Wieteska
Michał Wieteska
MMMateusz Midura
Mateusz Midura
GDGrzegorz Domański
Grzegorz Domański
DWDamian Wanta
Damian Wanta
PBPiotr Bogorodzki
Piotr Bogorodzki
The aim of the article was to analyze the potential simultaneous use of magnetic nanoparticles as contrast agents in MRI imaging and for magnetic hyperthermia. The study proposed characterizing the nanoparticles using various measurement methods in order to investigate the relationships between different properties. The first stage involved measuring images of nanoparticle samples using scanning transmission electron microscopy (TEM) and dynamic light scattering (DLS). The diameter distribution of nanoparticles was determined based on image segmentation. The next step involved measuring relaxation properties of nanoparticles in low and high magnetic fields. The research was carried out for nanoparticle solutions of various concentrations and properties. The last step was measuring calorimetric properties of nanoparticles as a thermal source under alternating magnetic field excitation conditions. The range of nanoparticle diameters (20–25 nm) for which maximum losses occur in an alternating magnetic field corresponds to the diameter range in which the maximum r2 relaxivity is observed.

28 August 2025 in Sensors
Verified
Journal Article
Open access
PDF file
MMMateusz Midura
Mateusz Midura
GDGrzegorz Domański
Grzegorz Domański
DWDamian Wanta
Damian Wanta
PWPrzemysław Wróblewski
Przemysław Wróblewski
Waldemar Tomasz SmolikWaldemar Tomasz Smolik
Waldemar Tomasz Smolik
PBPiotr Bogorodzki
Piotr Bogorodzki
The aim of the study was to analyze the impedance characteristics of the transmitting coil used in a system for AC magnetometry and the measurement of the Specific Absorption Rate (SAR) of magnetic nanoparticles. A theoretical relationship for the current distribution in a multilayer air-core coil was derived. The formulas for the coil’s stray capacitance were modified to account for additional spacing between layers, introduced to reduce the interlayer capacitance. The developed theory was applied to a two-layer air-core coil with an additional gap between the layers. The frequency dependence of the coil impedance was measured. The measurements confirmed an extension of the useful operating frequency range of the constructed coil.

22 July 2025 in IEEE Journal of Selected Topics in Quantum Electronics
Verified
Journal Article
Open access
NMNeda Mogharari
Neda Mogharari
MKMichal Kacprzak
Michal Kacprzak
KLKamil Lipiński
Kamil Lipiński
ALAdam Liebert
Adam Liebert
SWStanislaw Wojtkiewicz
Stanislaw Wojtkiewicz
In this study, first we compared the performance of continuous wave diffuse correlation spectroscopy (cw-DCS) and time domain diffuse correlation spectroscopy (td-DCS) in assessing the dynamic of scatterers during series of measurements on two-layered phantoms. Then, we compared the blood flow index (BFI) measured by DCS modalities and evaluated its correlation with the blood oxygenation level–dependent (BOLD) signal measured by magnetic resonance imaging (MRI) during respiratory challenges, including breath-holding (BH) and hyperventilation (HV). We found a good agreement between the amplitude changes of BFIs and BOLD signal in response to BH and HV maneuvers. Moreover, we observed positive correlations between the BFIs and BOLD signal changes in response to these respiratory challenges. Notably, during BH, BFI changes preceded the BOLD signal (on average by about 2.7s), while during HV, the responses were nearly simultaneous (delay about 0.2s). These results support the potential of DCS techniques as complementary a tool in assessing cerebral hemodynamic. However, to make these optical techniques practically useful, further improvements in hardware—especially in coherence length and pulse width of the td-DCS laser source is necessary.