Ivan Ibanez

Dr. Ivan Ibanez

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2020 in Engineering Science and Technology, an International Journal
Verified
Journal Article
Open access
IIIvan Ibanez
Ivan Ibanez
BZBajram Zeqiri
Bajram Zeqiri
MHM. Hodnett
M. Hodnett
MFMauricio Nogueira Frota
Mauricio Nogueira Frota

16 December 2020 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
IIIvan Ibanez
Ivan Ibanez
BGBruno A. de Azevedo Gomes
Bruno A. de Azevedo Gomes
ANAngela Ourivio Nieckele
Angela Ourivio Nieckele

15 February 2022 in Arquivos Brasileiros de Cardiologia
Verified
Journal Article
Open access
PDF file
GAGabriela Almeida
Gabriela Almeida
BGBruno Alvares de Azevedo Gomes
Bruno Alvares de Azevedo Gomes
Fabiula Schwartz AzevedoFabiula Schwartz Azevedo
Fabiula Schwartz Azevedo
KKKarim Kalaun
Karim Kalaun
IIIvan Ibanez
Ivan Ibanez
ANAngela Ourivio Nieckele
Angela Ourivio Nieckele
Resumo Fundamentos Uma metodologia para identificação de pacientes portadores de aneurisma de aorta ascendente (AAAs) sob alto risco de remodelamento aórtico não está completamente definida. Objetivo Esta pesquisa objetiva caracterizar numericamente o fluxo sanguíneo aórtico, relacionando a distribuição do estresse mecânico resultante com o crescimento de AAAs. Métodos Estudo analítico, observacional, unicêntrico, em que um protocolo de fluidodinâmica computacional (CFD – Computacional Fluid Dynamics) foi aplicado a imagens de angiotomografia computadorizada (ATC) de aorta de pacientes portadores de AAAs. Duas [...] Resumo Fundamentos Uma metodologia para identificação de pacientes portadores de aneurisma de aorta ascendente (AAAs) sob alto risco de remodelamento aórtico não está completamente definida. Objetivo Esta pesquisa objetiva caracterizar numericamente o fluxo sanguíneo aórtico, relacionando a distribuição do estresse mecânico resultante com o crescimento de AAAs. Métodos Estudo analítico, observacional, unicêntrico, em que um protocolo de fluidodinâmica computacional (CFD – Computacional Fluid Dynamics) foi aplicado a imagens de angiotomografia computadorizada (ATC) de aorta de pacientes portadores de AAAs. Duas

22 February 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
Fabiula Schwartz AzevedoFabiula Schwartz Azevedo
Fabiula Schwartz Azevedo
GAGabriela Almeida
Gabriela Almeida
BABruno Alvares de Azevedo
Bruno Alvares de Azevedo
IIIvan Ibanez
Ivan Ibanez
BABruno Nieckele Azevedo
Bruno Nieckele Azevedo
GOGlaucia Oliveira
Glaucia Oliveira
Ascending aortic aneurysm (AAoA) is a silent disease with high mortality; however, the factors associated with a worse prognosis are not completely understood. The objective of this observational, longitudinal, single-center study was to identify the hemodynamic patterns and their influence on AAoA growth using computational fluid dynamics (CFD), focusing on the effects of geometrical variations on aortic hemodynamics. Personalized anatomic models were obtained from angiotomography scans of 30 patients in two different years (with intervals of one to three years between them), of which 16 (53%) showed aneurysm growth (defined as an increase in the ascending aorta volume by 5% or more). Numerically determined velocity and pressure fields were compared with the outcome of aneurysm growth. Through a statistical analysis, hemodynamic characteristics were found to be associated with aneurysm growth: average and maximum high pressure (superior to 100 Pa); average and maximum high wall shear stress (superior to 7 Pa) combined with high pressure (>100 Pa); and stress load over time (maximum pressure multiplied by the time interval between the exams). This study provides insights into a worse prognosis of this serious disease and may collaborate for the expansion of knowledge about mechanobiology in the progression of AAoA.

14 May 2020 in Arquivos Brasileiros de Cardiologia
Verified
Journal Article
Open access
PDF file
DCDiego Celis
Diego Celis
BGBruno Alvares de Azevedo Gomes
Bruno Alvares de Azevedo Gomes
IIIvan Ibanez
Ivan Ibanez
PAPedro Nieckele Azevedo
Pedro Nieckele Azevedo
PTPedro Soares Teixeira
Pedro Soares Teixeira
ANAngela Ourivio Nieckele
Angela Ourivio Nieckele
Backgroud Transcatheter aortic valve replacement (TAVR) can reduce mortality among patients with aortic stenosis. Knowledge of pressure distribution and shear stress at the aortic wall may help identify critical regions, where aortic remodeling process may occur. Here a numerical simulation study of the influence of positioning of the prosthetic valve orifice on the flow field is presented. Objective The present analysis provides a perspective of great variance on flow behavior due only to angle changes. Methods A 3D model [...] Abstract Backgroud Transcatheter aortic valve replacement (TAVR) can reduce mortality among patients with aortic stenosis. Knowledge of pressure distribution and shear stress at the aortic wall may help identify critical regions, where aortic remodeling process may occur. Here a numerical simulation study of the influence of positioning of the prosthetic valve orifice on the flow field is presented. Objective The present analysis provides a perspective of great variance on flow behavior due only to angle changes. Methods A 3D model

7 September 2025 in Flow Measurement and Instrumentation
Verified
Journal Article
Closed access
EMEmanuel Alexander Moreno-Aldana
Emanuel Alexander Moreno-Aldana
MFMauricio Nogueira Frota
Mauricio Nogueira Frota
IIIvan Ibanez
Ivan Ibanez
SGSergio B. Germano
Sergio B. Germano