This paper describes a new concept for an ultrasonic cavitation sensor designed specifically for monitoring acoustic emissions generated by small microbubbles when driven by an applied acoustic field. Its novel features include a hollow, open-ended, cylindrical shape, with the sensor being a right circular cylinder of height 32 mm and external diameter 38 mm. The internal diameter of the sensor is 30 mm; its inner surface is fabricated from a 110 /spl mu/m layer of piezoelectrically active film whose measurement bandwidth is sufficient to enable acoustic emissions up to and beyond 10 MHz to be monitored. When in use, the sensor is immersed within the liquid test medium and high frequency (megahertz) acoustic emissions occurring within the hollow body of the sensor are monitored. In order to shield the sensor response from events occurring outside the cylinder, the outer surface of the sensor cylinder is encapsulated within a special 4 mm thick polyurethane-based cavitation shield with acoustic properties specifically developed to be minimally perturbing to the 40 kHz applied acoustic field but attenuating to ultrasound generated at megahertz frequencies (plane-wave transmission loss >30 dB at 1 MHz). This paper introduces the rationale behind the new sensor, describing details of its construction and the materials formulation program undertaken to develop the cavitation shield.
10 October 2022 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
This article presents basic principles of hydrophone measurements, including mechanisms of action for various hydrophone designs, sensitivity and directivity calibration procedures, practical considerations for performing measurements, signal processing methods to correct for both frequency-dependent sensitivity and spatial averaging across the hydrophone sensitive element, uncertainty in hydrophone measurements, special considerations for high-intensity therapeutic ultrasound, and advice for choosing an appropriate hydrophone for a particular measurement task. Recommendations are made for information to be included in hydrophone measurement reporting.
For Part I see ibid., vol.50, no.10, p.1342 (2003). This paper describes a series of experimental studies to evaluate the performance of newly developed sensors for monitoring broadband acoustic emissions generated by acoustic cavitation. The prototype sensors are fabricated in the form of hollow, open-ended cylinders, whose inner surface is made from a thin film of piezoelectric polymer acting as a passive acoustic receiver of bandwidth greater than 10 MHz. A 4 mm thick coating of special acoustical absorber forms the outer surface of the sensor. The layer functions as a shield to cavitation events occurring outside the hollow sensor body, allowing megahertz acoustic emissions emanating from within the liquid contained in the sensor to be monitored. Testing of the new sensor concept has been carried out within the cavitating field provided by a commercial ultrasonic cleaning vessel operating at 40 kHz whose power output is rated at 1 kW. It is demonstrated that the prototype cavitation sensors are able to record a systematic increase in the level of the high-frequency acoustic spectrum (>1 MHz) as electrical power to the cleaning vessel is increased. Through careful control of the experimental conditions, reproducibility of the high frequency "energy" associated with the cavitation spectrum was found to be typically /spl plusmn/25%.
21 June 2021 in IEEE Transactions on Medical Imaging
Photoacoustic imaging (PAI) standardisation demands a stable, highly reproducible physical phantom to enable routine quality control and robust performance evaluation. To address this need, we have optimised a low-cost copolymer-in-oil tissue-mimickingmaterial formulation. The base material consists of mineral oil, copolymer and stabiliser with defined Chemical Abstract Service numbers. Speed of sound c ( f ) and acoustic attenuation coefficient $\alpha $ (f) were characterised over 2–10 MHz; optical absorption $\mu _{\mathrm {a}}$ ( $\lambda $ ) and reduced scattering $\mu _{\mathrm {s}}$ ’( $\lambda $ ) coefficients over 450–900 nm. Acoustic properties were optimised by modifying base component ratios and optical properties were adjusted using additives. The temporal, thermomechanical and photo-stabilitywere studied, alongwith intra-laboratory fabrication and field-testing. c(f) could be tuned up to (1516±0.6) $\text{m}\cdot \text{s}^{-1}$ and $\alpha $ (f) to (17.4±0.3)dB $\cdot $ cm $^{-1}$ at 5 MHz. The base material exhibited negligible $\mu _{\mathrm {a}}$ ( $\lambda $ ) and $\mu _{\mathrm {s}}$ ’( $\lambda $ ), which could be independently tuned by addition of Nigrosin or TiO 2 respectively. These properties were stable over almost a year and were minimally affected by recasting. The material showed high intra-laboratory reproducibility (coefficient of variation <4% for ${c}$ ( ${f}$ ), $\alpha $ ( ${f}$ ), optical transmittance and reflectance), and good photo- and mechanical-stability in the relevant working range (20–40°C). The optimised copolymer-in-oil material represents an excellent candidate for widespread application in PAI phantoms, with properties suitable for broader use in biophotonics and ultrasound imaging standardisation efforts.