Carsten Pitsch

Mr. Carsten Pitsch


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2023 in Applied Optics
Verified
Journal Article
Closed access
CPCarsten Pitsch
Carsten Pitsch
DWDominik Walter
Dominik Walter
Leonardo GaspariniLeonardo Gasparini
Leonardo Gasparini
HBHelge Bürsing
Helge Bürsing
MEMarc Eichhorn
Marc Eichhorn
We present current results of a novel, to the best of our knowledge, type of setup for quantum ghost imaging based on asynchronous single photon timing using single photon avalanche diode (SPAD) detectors, first presented in [ Appl. Opt. 60, F66 (2021)APOPAI 0003-6935 10.1364/AO.423634 ]. The scheme enables photon pairing without fixed delays and, thus, overcomes some limitations of the widely used heralded setups for quantum ghost imaging [ Nat. Commun. 6, 5913 (2015)NCAOBW 2041-1723 10.1038/ncomms6913 ]. It especially allows three-dimensional (3D) imaging by direct time of flight methods, the first demonstration of which will be shown here. To our knowledge, it is also the first demonstration of 3D quantum ghost imaging at all.

1 October 2025 in APL Photonics
Verified
Journal Article
Open access
CPCarsten Pitsch
Carsten Pitsch
ASAlessia Suprano
Alessia Suprano
BGBenjamin Guery
Benjamin Guery
FPFrancesco Poggiali
Francesco Poggiali
CMChiara Michelini
Chiara Michelini
FVFederica Villa
Federica Villa
Quantum Ghost Imaging (QGI) is a powerful imaging technique that enables probing of an object using illumination levels beyond classical limits and does not rely on a single-photon-sensitive camera in the spectrum of interest. Current “heralded” QGI setups provide high-resolution images with intensified charge-coupled device (ICCD) cameras, but their acquisition time and applicability are limited by setup complexity and detector dead time. Recently, new setups using single photon detection and time-tagging have been shown to allow more efficient acquisition while also enabling new applications, such as remote 3D imaging using “asynchronous” QGI. Here, we demonstrate novel results of two asynchronous QGI setups, using a dedicated high duty-cycle single photon avalanche diode array to drastically reduce acquisition time to sub-second regime, demonstrating video acquisition at 10 fps. As this scheme allows interoperability with arbitrary single photon timing detectors, it can be adapted to a variety of applications and is not bound by the detection window of silicon-based detectors. We further study the impact of the choice of bucket detector and pump laser, using readily available off-the-shelf detectors and lasers. Summarizing the findings, we discuss the remaining limitations for real-time imaging and give an outlook on upcoming developments and an outline of further applications of both detectors and detection scheme.

18 April 2024 in Sensors
Verified
Journal Article
Open access
PDF file
CPCarsten Pitsch
Carsten Pitsch
DWDominik Walter
Dominik Walter
Leonardo GaspariniLeonardo Gasparini
Leonardo Gasparini
HBHelge Bürsing
Helge Bürsing
MEMarc Eichhorn
Marc Eichhorn
Single-photon detection and timing has attracted increasing interest in recent years due to their necessity in the field of quantum sensing and the advantages of single-quanta detection in the field of low-level light imaging. While simple bucket detectors are mature enough for commercial applications, more complex imaging detectors are still a field of research comprising mostly prototype-level detectors. A major problem in these detectors is the implementation of in-pixel timing circuitry, especially for two-dimensional imagers. One of the most promising approaches is the use of voltage-controlled ring resonators in every pixel. Each of these runs independently based on a voltage supplied by a global reference. However, this yields the problem that the supply voltage can change across the chip which, in turn, changes the period of the ring resonator. Due to additional parasitic effects, this problem can worsen with increasing measurement time, leading to drift in the timing information. We present here a method to identify and correct such temporal drifts in single-photon detectors based on asynchronous quantum ghost imaging. We also show the effect of this correction on recent quantum ghost imaging (QGI) measurement from our group.

28 March 2023 in Optica Open
Verified
Preprint
Open access
PDF file
CPCarsten Pitsch
Carsten Pitsch
DWDominik Walter
Dominik Walter
LGLeonardo Gasparini
Leonardo Gasparini
HBHelge Bürsing
Helge Bürsing
MEMarc Eichhorn
Marc Eichhorn
We present current results of a novel type of setup for quantum ghost imaging based on asynchronous single-photon timing using SPAD detectors, first presented in [1]. The scheme enables photon pairing without fixed delays and thus overcomes some limitations of the widely used heralded setups for quantum ghost imaging [2]. It especially allows 3-dimensional imaging by direct Time of Flight methods, the first demonstration of which will be shown here. To our knowledge it is also the first demonstration of 3-dimensional Quantum Ghost Imaging at all.

28 March 2023 in Optica Open
Verified
Preprint
Open access
PDF file
CPCarsten Pitsch
Carsten Pitsch
DWDominik Walter
Dominik Walter
LGLeonardo Gasparini
Leonardo Gasparini
HBHelge Bürsing
Helge Bürsing
MEMarc Eichhorn
Marc Eichhorn
We present current results of a novel type of setup for quantum ghost imaging based on asynchronous single-photon timing using SPAD detectors, first presented in [1]. The scheme enables photon pairing without fixed delays and thus overcomes some limitations of the widely used heralded setups for quantum ghost imaging [2]. It especially allows 3-dimensional imaging by direct Time of Flight methods, the first demonstration of which will be shown here. To our knowledge it is also the first demonstration of 3-dimensional Quantum Ghost Imaging at all.