Agüí Lourdes

Mrs. Agüí Lourdes


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2017 in Biosensors
Verified
Journal Article
Open access
PDF file
GMGonzalo Martínez-García
Gonzalo Martínez-García
EPElena Pérez-Julián
Elena Pérez-Julián
ALAgüí Lourdes
Agüí Lourdes
NCNoemí Cabré
Noemí Cabré
Jorge JovenJorge Joven
Jorge Joven
José Manuel PingarrónJosé Manuel Pingarrón
José Manuel Pingarrón
A biosensor for 3-hydroxybutyrate (3-HB) involving immobilization of the enzyme 3-hydroxybutyrate dehydrogenase onto a screen-printed carbon electrode modified with reduced graphene oxide (GO) and thionine (THI) is reported here. After addition of 3-hydroxybutyrate or the sample in the presence of NAD+ cofactor, the generated NADH could be detected amperometrically at 0.0 V vs. Ag pseudo reference electrode. Under the optimized experimental conditions, a calibration plot for 3-HB was constructed showing a wide linear range between 0.010 and 0.400 mM 3-HB which covers the clinically relevant levels for diluted serum samples. In addition, a limit of detection of 1.0 µM, much lower than that reported using other biosensors, was achieved. The analytical usefulness of the developed biosensor was demonstrated via application to spiked serum samples.

29 October 2019 in Biosensors
Verified
Journal Article
Open access
PDF file
PYPaloma Yáñez-Sedeño
Paloma Yáñez-Sedeño
ALAgüí Lourdes
Agüí Lourdes
SCSusana Campuzano
Susana Campuzano
José Manuel PingarrónJosé Manuel Pingarrón
José Manuel Pingarrón
This article critically discusses the latest advances in the use of voltammetric, amperometric, potentiometric, and impedimetric biosensors for forensic analysis. Highlighted examples that show the advantages of these tools to develop methods capable of detecting very small concentrations of analytes and provide selective determinations through analytical responses, without significant interferences from other components of the samples, are presented and discussed, thus stressing the great versatility and utility of electrochemical biosensors in this growing research field. To illustrate this, the determination of substances with forensic relevance by using electrochemical biosensors reported in the last five years (2015–2019) are reviewed. The different configurations of enzyme or affinity biosensors used to solve analytical problems related to forensic practice, with special attention to applications in complex samples, are considered. Main prospects, challenges to focus, such as the fabrication of devices for rapid analysis of target analytes directly on-site at the crime scene, or their widespread use and successful applications to complex samples of interest in forensic analysis, and future efforts, are also briefly discussed.

11 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Esther Sánchez TiradoEsther Sánchez Tirado
Esther Sánchez Tirado
ALAgüí Lourdes
Agüí Lourdes
Araceli González-CortésAraceli González-Cortés
Araceli González-Cortés
SCSusana Campuzano
Susana Campuzano
PYPaloma Yáñez-Sedeño
Paloma Yáñez-Sedeño
José Manuel PingarrónJosé Manuel Pingarrón
José Manuel Pingarrón
The study of the human microbiome is a multidisciplinary area ranging from the field of technology to that of personalized medicine. The possibility of using microbiota biomarkers to improve the diagnosis and monitoring of diseases (e.g., cancer), health conditions (e.g., obesity) or relevant processes (e.g., aging) has raised great expectations, also in the field of bioelectroanalytical chemistry. The well-known advantages of electrochemical biosensors—high sensitivity, fast response, and the possibility of miniaturization, together with the potential for new nanomaterials to improve their design and performance—position them as unique tools to provide a better understanding of the entities of the human microbiome and raise the prospect of huge and important developments in the coming years. This review article compiles recent applications of electrochemical (bio)sensors for monitoring microbial metabolites and disease biomarkers related to different types of human microbiome, with a special focus on the gastrointestinal microbiome. Examples of electrochemical devices applied to real samples are critically discussed, as well as challenges to be faced and where future developments are expected to go.

13 March 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
Esther Sánchez TiradoEsther Sánchez Tirado
Esther Sánchez Tirado
ALAgüí Lourdes
Agüí Lourdes
MLMarta Sánchez-Paniagua López
Marta Sánchez-Paniagua López
Araceli González-CortésAraceli González-Cortés
Araceli González-Cortés
BRBEATRIZ LOPEZ RUIZ
BEATRIZ LOPEZ RUIZ
José Manuel PingarrónJosé Manuel Pingarrón
José Manuel Pingarrón
Rheumatoid arthritis (RA) is a systemic chronic autoimmune inflammatory disease that is characterized by the destruction of bone and production of autoantibodies such as rheumatoid factor (RF) and anticitrullinated protein antibodies (ACPAs). The high prevalence of this disease and the need of affordable tools for its early detection led us to prepare the first electrochemical immunoplatform for the simultaneous determination of four RA biomarkers, the autoantibodies: RF, anti-peptidyl-arginine deiminase enzyme (anti-PAD4), anti-cyclic citrullinated peptide (anti-CCP), and anti-citrullinated vimentin (anti-MCV). Functionalized magnetic beads (MBs) were used to immobilize the specific antigens, and sandwich-type immunoassays were implemented for the amperometric detection of the four autoantibodies, using the horseradish peroxidase (HRP)/H2O2/hydroquinone (HQ) system. The immunoplatform was applied to the determination of the biomarkers in human serum of twenty-two patients diagnosed with RA and four healthy individuals, and the results were validated against ELISA tests and the certified values.

7 August 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
SGSara Guerrero
Sara Guerrero
Esther Sánchez TiradoEsther Sánchez Tirado
Esther Sánchez Tirado
ALAgüí Lourdes
Agüí Lourdes
Araceli González-CortésAraceli González-Cortés
Araceli González-Cortés
PYPaloma Yáñez-Sedeño
Paloma Yáñez-Sedeño
José Manuel PingarrónJosé Manuel Pingarrón
José Manuel Pingarrón
Serum level of CCL5 chemokine is considered an emerging biomarker for multiple sclerosis (MS). Due to the lack of specific assays for this disease, the development of a point-of-care test for rapid detection of MS could lead to avoiding diagnostics delays. In this paper, we report the first electrochemical immunoplatform for quantification of the CCL5 biomarker at the clinically required levels, able to discriminate between patients diagnosed with MS and healthy individuals. The immunosensing device involves protein capture from biological samples by complexation with biotinylated specific antibodies immobilized onto neutravidin-functionalized microparticles and sandwich assay with anti-CCL5 antibody and IgG labelled with horseradish peroxidase (HRP) for the enzyme-catalyzed amperometric detection of H2O2 using hydroquinone (HQ) as the redox mediator. The method shows excellent analytical performance for clinical application with a wide linear range of concentrations (0.1–300 ng·mL−1 CCL5, R2 = 0.998) and a low detection limit (40 pg·mL−1 CCL5). The biosensing platform was applied to the determination of the CCL5 endogenous content in 100-fold diluted sera both from healthy individuals and patients diagnosed with MS, with no further sample treatment in just two hours. The results were successfully compared with those obtained by the ELISA methodology.

27 July 2022 in Chemosensors
Verified
Journal Article
Open access
PDF file
Esther Sánchez TiradoEsther Sánchez Tirado
Esther Sánchez Tirado
ALAgüí Lourdes
Agüí Lourdes
Araceli González-CortésAraceli González-Cortés
Araceli González-Cortés
PYPaloma Yáñez-Sedeño
Paloma Yáñez-Sedeño
José Manuel PingarrónJosé Manuel Pingarrón
José Manuel Pingarrón
Chemokines are a class of cytokine whose special properties, together with their involvement and relevant role in various diseases, make them a restricted group of biomarkers suitable for diagnosis and monitoring. Despite their importance, biodetection techniques dedicated to the selective determination of one or more chemokines are very scarce. For some years now, the critical diagnosis of inflammatory diseases by detecting both cytokine and chemokine biomarkers, has had a strong impact on the development of multiple detection platforms. However, it would be desirable to implement methodologies with a higher degree of selectivity for chemokines, in order to provide more precise information. In addition, better development of biosensor technology applied to this specific field would make it possible to address the main challenges of detection methods for several diseases with a high incidence in the population, avoiding high costs and low sensitivity. Taking this into account, this review aims to present the state of the art of chemokine biodetection techniques and emphasize the role of these systems in the prevention, monitoring and treatment of various diseases associated with chemokines as a starting point for future developments that are also analyzed throughout the article.