Background: Previous research applying large language models (LLMs) to medicine was focused on text-based information. Recently, multimodal variants of LLMs acquired the capability of recognizing images. Objective: We aim to evaluate the image recognition capability of generative pretrained transformer (GPT)-4V, a recent multimodal LLM developed by OpenAI, in the medical field by testing how visual information affects its performance to answer questions in the 117th Japanese National Medical Licensing Examination. Methods: We focused on 108 questions that had 1 or more images as part of a question and presented GPT-4V with the same questions under two conditions: (1) with both the question text and associated images and (2) with the question text only. We then compared the difference in accuracy between the 2 conditions using the exact McNemar test. Results: Among the 108 questions with images, GPT-4V’s accuracy was 68% (73/108) when presented with images and 72% (78/108) when presented without images (P=.36). For the 2 question categories, clinical and general, the accuracies with and those without images were 71% (70/98) versus 78% (76/98; P=.21) and 30% (3/10) versus 20% (2/10; P≥.99), respectively. Conclusions: The additional information from the images did not significantly improve the performance of GPT-4V in the Japanese National Medical Licensing Examination.
Purpose: The target disorders of emergency head CT are wide-ranging. Therefore, people working in an emergency department desire a computer-aided detection system for general disorders. In this study, we proposed an unsupervised anomaly detection method in emergency head CT using an autoencoder and evaluated the anomaly detection performance of our method in emergency head CT. Methods: We used a 3D convolutional autoencoder (3D-CAE), which contains 11 layers in the convolution block and 6 layers in the deconvolution block. In the training phase, we trained the 3D-CAE using 10,000 3D patches extracted from 50 normal cases. In the test phase, we calculated abnormalities of each voxel in 38 emergency head CT volumes (22 abnormal cases and 16 normal cases) for evaluation and evaluated the likelihood of lesion existence. Results: Our method achieved a sensitivity of 68% and a specificity of 88%, with an area under the curve of the receiver operating characteristic curve of 0.87. It shows that this method has a moderate accuracy to distinguish normal CT cases to abnormal ones. Conclusion: Our method has potentialities for anomaly detection in emergency head CT.
Purpose: To assess the performance of GPT-4 Turbo with Vision (GPT-4TV), OpenAI’s latest multimodal large language model, by comparing its ability to process both text and image inputs with that of the text-only GPT-4 Turbo (GPT-4 T) in the context of the Japan Diagnostic Radiology Board Examination (JDRBE). Materials and methods: The dataset comprised questions from JDRBE 2021 and 2023. A total of six board-certified diagnostic radiologists discussed the questions and provided ground-truth answers by consulting relevant literature as necessary. The following questions were excluded: those lacking associated images, those with no unanimous agreement on answers, and those including images rejected by the OpenAI application programming interface. The inputs for GPT-4TV included both text and images, whereas those for GPT-4 T were entirely text. Both models were deployed on the dataset, and their performance was compared using McNemar’s exact test. The radiological credibility of the responses was assessed by two diagnostic radiologists through the assignment of legitimacy scores on a five-point Likert scale. These scores were subsequently used to compare model performance using Wilcoxon's signed-rank test. Results: The dataset comprised 139 questions. GPT-4TV correctly answered 62 questions (45%), whereas GPT-4 T correctly answered 57 questions (41%). A statistical analysis found no significant performance difference between the two models (P = 0.44). The GPT-4TV responses received significantly lower legitimacy scores from both radiologists than the GPT-4 T responses. Conclusion: No significant enhancement in accuracy was observed when using GPT-4TV with image input compared with that of using text-only GPT-4 T for JDRBE questions.
18 February 2016 in American Journal of Neuroradiology
BACKGROUND AND PURPOSE: Experiences with computer-assisted detection of cerebral aneurysms in diagnosis by radiologists in real-life clinical environments have not been reported. The purpose of this study was to evaluate the usefulness of computer-assisted detection in a routine reading environment. MATERIALS AND METHODS: During 39 months in a routine clinical practice environment, 2701 MR angiograms were each read by 2 radiologists by using a computer-assisted detection system. Initial interpretation was independently made without using the detection system, followed by a possible alteration of diagnosis after referring to the lesion candidate output from the system. We used the final consensus of the 2 radiologists as the reference standard. The sensitivity and specificity of radiologists before and after seeing the lesion candidates were evaluated by aneurysm- and patient-based analyses. RESULTS: The use of the computer-assisted detection system increased the number of detected aneurysms by 9.3% (from 258 to 282). Aneurysm-based analysis revealed that the apparent sensitivity of the radiologists9 diagnoses made without and with the detection system was 64% and 69%, respectively. The detection system presented 82% of the aneurysms. The detection system more frequently benefited radiologists than being detrimental. CONCLUSIONS: Routine integration of computer-assisted detection with MR angiography for cerebral aneurysms is feasible, and radiologists can detect a number of additional cerebral aneurysms by using the detection system without a substantial decrease in their specificity. The low confidence of radiologists in the system may limit its usefulness.
Objective. To develop automatic visceral fat volume calculation software for computed tomography (CT) volume data and to evaluate its feasibility.Methods. A total of 24 sets of whole-body CT volume data and anthropometric measurements were obtained, with three sets for each of four BMI categories (under 20, 20 to 25, 25 to 30, and over 30) in both sexes. True visceral fat volumes were defined on the basis of manual segmentation of the whole-body CT volume data by an experienced radiologist. Software to automatically calculate visceral fat volumes was developed using a region segmentation technique based on morphological analysis with CT value threshold. Automatically calculated visceral fat volumes were evaluated in terms of the correlation coefficient with the true volumes and the error relative to the true volume.Results. Automatic visceral fat volume calculation results of all 24 data sets were obtained successfully and the average calculation time was 252.7 seconds/case. The correlation coefficients between the true visceral fat volume and the automatically calculated visceral fat volume were over 0.999.Conclusions. The newly developed software is feasible for calculating visceral fat volumes in a reasonable time and was proved to have high accuracy.