Yoshitaka Masutani

Yoshitaka Masutani

Auto-generated profile, based on publicly available information

Yoshitaka Masutani

Department of Medical Image Computation, Tohoku University Graduate School of Medicine, Sendai, Japan

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2016 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
SMSoichiro Miki
Soichiro Miki
NHNaoto Hayashi
Naoto Hayashi
YMY. Masutani
Y. Masutani
YNYukihiro Nomura
Yukihiro Nomura
TYT. Yoshikawa
T. Yoshikawa
KOK. Ohtomo
K. Ohtomo
BACKGROUND AND PURPOSE: Experiences with computer-assisted detection of cerebral aneurysms in diagnosis by radiologists in real-life clinical environments have not been reported. The purpose of this study was to evaluate the usefulness of computer-assisted detection in a routine reading environment. MATERIALS AND METHODS: During 39 months in a routine clinical practice environment, 2701 MR angiograms were each read by 2 radiologists by using a computer-assisted detection system. Initial interpretation was independently made without using the detection system, followed by a possible alteration of diagnosis after referring to the lesion candidate output from the system. We used the final consensus of the 2 radiologists as the reference standard. The sensitivity and specificity of radiologists before and after seeing the lesion candidates were evaluated by aneurysm- and patient-based analyses. RESULTS: The use of the computer-assisted detection system increased the number of detected aneurysms by 9.3% (from 258 to 282). Aneurysm-based analysis revealed that the apparent sensitivity of the radiologists9 diagnoses made without and with the detection system was 64% and 69%, respectively. The detection system presented 82% of the aneurysms. The detection system more frequently benefited radiologists than being detrimental. CONCLUSIONS: Routine integration of computer-assisted detection with MR angiography for cerebral aneurysms is feasible, and radiologists can detect a number of additional cerebral aneurysms by using the detection system without a substantial decrease in their specificity. The low confidence of radiologists in the system may limit its usefulness.

24 November 2006 in Radiation Medicine
Verified
Journal Article
Closed access
PDF file
MWMakoto Watanabe
Makoto Watanabe
SAShigeki Aoki
Shigeki Aoki
YMYoshitaka Masutani
Yoshitaka Masutani
OAOsamu Abe
Osamu Abe
NHNaoto Hayashi
Naoto Hayashi
KOKuni Ohtomo
Kuni Ohtomo

1 January 2017 in Medical Image Analysis
Verified
Journal Article
Closed access
SHShouhei Hanaoka
Shouhei Hanaoka
ASAkinobu Shimizu
Akinobu Shimizu
MNMitsutaka Nemoto
Mitsutaka Nemoto
YNYukihiro Nomura
Yukihiro Nomura
SMSoichiro Miki
Soichiro Miki
YMYoshitaka Masutani
Yoshitaka Masutani

16 April 2007 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
KNKeiichi Nakagawa
Keiichi Nakagawa
KYKiyoshi Yoda
Kiyoshi Yoda
YMYoshitaka Masutani
Yoshitaka Masutani
KSKatsutake Sasaki
Katsutake Sasaki
KOKuni Ohtomo
Kuni Ohtomo
A compensator made of a tungsten-based rod matrix has been proposed for small-field intensity modulated radiation therapy. The compensator was attached to a 6 MV linac gantry head. The proposed compensator could modulate the X-ray intensity with a step of 10% and a minimum transmission of 2.5%

1 March 2005 in American Journal of Roentgenology
Verified
Journal Article
Closed access
HMHarushi Mori
Harushi Mori
TFTakashi Fijishiro
Takashi Fijishiro
NHNaoto Hayashi
Naoto Hayashi
YMYoshitaka Masutani
Yoshitaka Masutani
SAShigeki Aoki
Shigeki Aoki
MWMasato Wakakura
Masato Wakakura

1 September 2004 in Journal of Computer Assisted Tomography
Verified
Journal Article
Closed access
OAOsamu Abe
Osamu Abe
HMHarushi Mori
Harushi Mori
SAShigeki Aoki
Shigeki Aoki
AKAkira Kunimatsu
Akira Kunimatsu
NHNaoto Hayashi
Naoto Hayashi
KOKuni Ohtomo
Kuni Ohtomo
To evaluate diffusion tensor imaging (DTI) based on periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) compared with DTI based on single-shot echo planar imaging (EPI). Diffusion tensor data were acquired with PROPELLER (PROPELLER-DTI, 3 NEX), EPI (EPI-DTI2, 16 NEX) with the same acquisition time (11.4 minutes) and with EPI (EPI-DTI1, number of excitations = 4) with a shorter acquisition time (2.8 minutes). Regions of interest were set in the genu and splenium of the corpus callosum, as determined on T2-weighted fast spin echo images and fractional anisotropy (FA) maps, separately. Two neuroradiologists visually evaluated image distortion and quality in the supra- and infratentorial structures. In the genu, standard deviation determined by respective FA maps was decreased in order of PROPELLER-DTI, EPI-DTI1, and EPI-DTI2. Both EPI-DTI sequences were quantitatively superior in the splenium, but PROPELLER-DTI was less distorted. Periodically rotated overlapping parallel lines with enhanced reconstruction-DTI could become a complementary tool when qualitatively evaluating seriously distorted structures.