Risa Robinson

Dr. Risa Robinson

orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
CLChad A Lerner
Chad A Lerner
ISIsaac K Sundar
Isaac K Sundar
HYHongwei Yao
Hongwei Yao
JGJanice Gerloff
Janice Gerloff
DODeborah J Ossip
Deborah J Ossip
Irfan RahmanIrfan Rahman
Irfan Rahman
Oxidative stress and inflammatory response are the key events in the pathogenesis of chronic airway diseases. The consumption of electronic cigarettes (e-cigs) with a variety of e-liquids/e-juices is alarmingly increasing without the unrealized potential harmful health effects. We hypothesized that electronic nicotine delivery systems (ENDS)/e-cigs pose health concerns due to oxidative toxicity and inflammatory response in lung cells exposed to their aerosols. The aerosols produced by vaporizing ENDS e-liquids exhibit oxidant reactivity suggesting oxidants or reactive oxygen species (OX/ROS) may be inhaled directly into the lung during a “vaping” session. These OX/ROS are generated through activation of the heating element which is affected by heating element status (new versus used), and occurs during the process of e-liquid vaporization. Unvaporized e-liquids were oxidative in a manner dependent on flavor additives, while flavors containing sweet or fruit flavors were stronger oxidizers than tobacco flavors. In light of OX/ROS generated in ENDS e-liquids and aerosols, the effects of ENDS aerosols on tissues and cells of the lung were measured. Exposure of human airway epithelial cells (H292) in an air-liquid interface to ENDS aerosols from a popular device resulted in increased secretion of inflammatory cytokines, such as IL-6 and IL-8. Furthermore, human lung fibroblasts exhibited stress and morphological change in response to treatment with ENDS/e-liquids. These cells also secrete increased IL-8 in response to a cinnamon flavored e-liquid and are susceptible to loss of cell viability by ENDS e-liquids. Finally, exposure of wild type C57BL/6J mice to aerosols produced from a popular e-cig increase pro-inflammatory cytokines and diminished lung glutathione levels which are critical in maintaining cellular redox balance. Thus, exposure to e-cig aerosols/juices incurs measurable oxidative and inflammatory responses in lung cells and tissues that could lead to unrealized health consequences.

8 June 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Risa RobinsonRisa Robinson
Risa Robinson
Edward HenselEdward Hensel
Edward Hensel
PMP. N. Morabito
P. N. Morabito
KRK. A. Roundtree
K. A. Roundtree
This paper presents the results of a clinical, observational, descriptive study to quantify the use patterns of electronic cigarette users in their natural environment. Previously published work regarding puff topography has been widely indirect in nature, and qualitative rather than quantitative, with the exception of three studies conducted in a laboratory environment for limited amounts of time. The current study quantifies the variation in puffing behaviors among users as well as the variation for a given user throughout the course of a day. Puff topography characteristics computed for each puffing session by each subject include the number of subject puffs per puffing session, the mean puff duration per session, the mean puff flow rate per session, the mean puff volume per session, and the cumulative puff volume per session. The same puff topography characteristics are computed across all puffing sessions by each single subject and across all subjects in the study cohort. Results indicate significant inter-subject variability with regard to puffing topography, suggesting that a range of representative puffing topography patterns should be used to drive machine-puffed electronic cigarette aerosol evaluation systems.

1 January 2001 in Aerosol Science and Technology
Verified
Journal Article
Open access
Risa RobinsonRisa Robinson
Risa Robinson
CYC. P. Yu
C. P. Yu
Understanding tobacco related cancer etiology requires the knowledge of cigarette smoke particle (CSP) deposition. Measurements of CSP deposition are inconsistent with typical deposition data. A deposition model that accounts for hygroscopic growth, coagulation, particle charge, and cloud behavior of CSP has not yet been presented. Nor have smoking patterns been accounted for in either deposition measurements or computer models. The dosimetry of Benzo[a]pyrene (BaP), which would add critical information to the relationship between anatomic site preferences of tumors and their histology, is currently unknown. The deposition model presented in this study is the first to accurately account for the dynamic behavior of CSP. Using the model results, the effects of each dynamic behavior on deposition is examined along with the effect of smoking patterns. The dosimetry of BaP is also calculated. The results indicate that coagulation, hygroscopicity, and particle charge increase the total deposition by 16% over the stable charge-neutral case, which predicts 46%. Cloud behavior increases total deposition efficiency by 36% over the simple case. Increasing exhalation time increases the deposition fraction by 3.9%/s. BaP concentrations are found to be as large as 1.8E-4ng/cm2 for the cloud model and 2.4E-5 ng/cm2 for single particle behavior. Mass deposition occurs preferentially in the pulmonary region for all cases. However, significant increases in the tracheo-bronchial region are found if cloud behavior is considered. The model results indicate that cloud behavior,and not particle charge, coagulation, and hygroscopic growth, has a predominant effect on deposition. More data is required on cloud behavior in the airways to improve the accuracy of the model.

13 October 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Risa RobinsonRisa Robinson
Risa Robinson
Edward HenselEdward Hensel
Edward Hensel
KRK A Roundtree
K A Roundtree
ADA G Difrancesco
A G Difrancesco
JNJ M Nonnemaker
J M Nonnemaker
YLY O Lee
Y O Lee
Results of an observational, descriptive study quantifying topography characteristics of twenty first generation electronic nicotine delivery system users in their natural environment for a one week observation period are presented. The study quantifies inter-participant variation in puffing topography between users and the intra-participant variation for each user observed during one week of use in their natural environment. Puff topography characteristics presented for each user include mean puff duration, flow rate and volume for each participant, along with descriptive statistics of each quantity. Exposure characteristics including the number of vaping sessions, total number of puffs and cumulative volume of aerosol generated from ENDS use (e-liquid aerosol) are reported for each participant for a one week exposure period and an effective daily average exposure. Significant inter-participant and intra-participant variation in puff topography was observed. The observed range of natural use environment characteristics is used to propose a set of topography protocols for use as command inputs to drive machine-puffed electronic nicotine delivery systems in a controlled laboratory environment.

4 June 2015 in Nicotine & Tobacco Research
Verified
Journal Article
Open access
PDF file
TPTodd Pagano
Todd Pagano
ADA. Gary DiFrancesco
A. Gary DiFrancesco
SSSusan B. Smith
Susan B. Smith
JGJerrin George
Jerrin George
GWGloria Wink
Gloria Wink
Risa RobinsonRisa Robinson
Risa Robinson
Electronic cigarettes (E-Cigs) are popular alternatives to conventional tobacco cigarettes. Disposable E-Cigs are single-use devices that emit aerosols from a nicotine-containing solution (e-liquid) by activating a heating coil during puffing. However, due to lack of regulations and standards, it is unclear how product claims are aligning with actual content and performance. Some analytical methods for characterizing E-Cigs are still in an exploratory phase. Five products of disposable E-Cigs (purchased March–April, 2014 from a local smoke shop and an on-line US distributor) were studied for nicotine content, number of puffs obtained before depletion, portion of nicotine delivered via aerosolization, and e-liquid pH. Protocols were developed to consistently extract e-liquid from puffed and unpuffed E-Cigs. An in-house mechanical puffing machine was used to consistently puff E-Cig aerosols onto filter pads. A gas chromatography-mass spectrometry method was developed that produced sensitive and repeatable nicotine determinations. Under our experimental parameters, results showed a disparity between nicotine content and number of puffs achieved relative to what was claimed on product packaging. The portion of nicotine delivered to filter pads was often less than half that which was available, indicating much of the nicotine may be left in the E-Cig upon depletion. Analyses of unpuffed E-Cigs by gas chromatography-mass spectrometry indicate the nicotine content of these products can be considerably different from manufacture’s labeling. Furthermore, a large portion of the nicotine in E-Cigs may not be transferred to the user, and that which is transferred, may often be in the less bioavailable form.

1 January 1998 in Aerosol Science and Technology
Verified
Journal Article
Open access
Risa RobinsonRisa Robinson
Risa Robinson
CYC. P. Yu
C. P. Yu
The deposition of cigarette smoke particles (CSP) in the human respiratory tract is difficult to predict theoretically due to the uncertainties in the characterization of these particles. Measured deposition efficiencies for CSP do not agree with those for typical particles of similar size. One explanation of this discrepancy is the hygroscopic growth of CSP once inside the respiratory tract. However, a minimum of experimental data exists and no theoretical study was done to explain the hygroscopic nature of CSP. In this paper, hygroscopic growth of mainstream and sidestream CSP is determined theoretically for conditions simulating the human respiratory tract. Good agreement is found between calculated growth and experimental growth reported in Li [Ph.D. Thesis, Department of Chemistry, Clarkson University, NY, (1993)] and Kousaka et al. [J. Chem. Eng. Jpn. 15: 75–76, (1982)]. Growth ratios ranging from 0 to 1.52 were found for mainstream CSP with initial sizes ranging from 0.03 to 0.6 μm. Growth ratios ranging from 0 to 1.35 were found for sidestream CSP with initial sizes ranging from 0.03 to 0.3 μm. CSP ranging from 0.03 to 0.6 μm reach their equilibrium diameters in less than 0.1 s. Further calculations indicated that CSP do not grow in subsaturated conditions less than 95% which agrees with results reported in Chen et al. [Aerosol Sci. Technol. 12: 364–375 (1990)] and Ishizu et al. [Beitr. zur Tabakforschung 10: 161–168 (1980)]. The hygroscopicity of CSP was found to be significantly less than a salt particle and the resulting growth rates were not large enough to explain the discrepancy between expected and measured deposition efficiencies.