Todd Pagano

Todd Pagano

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2017 in Applied In Vitro Toxicology
Verified
Journal Article
Open access
JGJanice Gerloff
Janice Gerloff
ISIsaac K. Sundar
Isaac K. Sundar
RFRobert Freter
Robert Freter
Emily Rose SekeraEmily Rose Sekera
Emily Rose Sekera
AFAlan E. Friedman
Alan E. Friedman
Irfan RahmanIrfan Rahman
Irfan Rahman
Recent studies suggest that electronic cigarette (e-cig) flavors can be harmful to lung tissue by imposing oxidative stress and inflammatory responses. The potential inflammatory response by lung epithelial cells and fibroblasts exposed to e-cig flavoring chemicals in addition to other risk-anticipated flavor enhancers inhaled by e-cig users is not known. The goal of this study was to evaluate the release of the proinflammatory cytokine (interleukin-8 [IL-8]) and epithelial barrier function in response to different e-cig flavoring chemicals identified in various e-cig e-liquid flavorings and vapors by chemical characterization using gas chromatography–mass spectrometry analysis. Flavorings, such as acetoin (butter), diacetyl, pentanedione, maltol (malt), ortho-vanillin (vanilla), coumarin, and cinnamaldehyde in comparison with tumor necrosis factor alpha (TNFα), were used in this study. Human bronchial epithelial cells (Beas2B), human mucoepidermoid carcinoma epithelial cells (H292), and human lung fibroblasts (HFL-1) were treated with each flavoring chemical for 24 hours. The cells and conditioned media were then collected and analyzed for toxicity (viability %), lung epithelial barrier function, and proinflammatory cytokine IL-8 release. Cell viability was not significantly affected by any of the flavoring chemicals tested at a concentration of 10 μM to 1 mM. Acetoin and diacetyl treatment induced IL-8 release in Beas2B cells. Acetoin- and pentanedione-treated HFL-1 cells produced a differential, but significant response for IL-8 release compared to controls and TNFα. Flavorings, such as ortho-vanillin and maltol, induced IL-8 release in Beas2B cells, but not in H292 cells. Of all the flavoring chemicals tested, acetoin and maltol were more potent inducers of IL-8 release than TNFα in Beas2B and HFL-1 cells. Flavoring chemicals rapidly impaired epithelial barrier function in human bronchial epithelial cells (16-HBE) as measured by electric cell surface impedance sensing. Our findings suggest that some of the e-cig liquids/aerosols containing flavoring chemicals can cause significant loss of epithelial barrier function and proinflammatory response in lung cells.

29 September 2014 in Water
Verified
Journal Article
Open access
PDF file
TPTodd Pagano
Todd Pagano
MBMorgan Bida
Morgan Bida
JKJonathan E. Kenny
Jonathan E. Kenny
Over the past several decades, dissolved organic carbon (DOC) in inland natural water systems has been a popular research topic to a variety of scientific disciplines. Part of the attention has been due to observed changes in DOC concentrations in many of the water systems of the Northern Hemisphere. Shifts in DOC levels, and changes in its composition, are of concern due to its significance in aquatic ecosystem functioning and its potential and realized negative effects on waters that might be treated for drinking purposes. While it may not be possible to establish sound cause and effect relationships using a limited number of drivers, through long-term DOC monitoring studies and a variety of laboratory/field experiments, several explanations for increasing DOC trends have been proposed, including two key mechanisms: decreased atmospheric acid deposition and the increasing impact of climate change agents. The purpose of this review is three-fold: to outline frequently discussed conceptual mechanisms used to explain DOC increases (especially under a changing climate), to discuss the structure of DOC and the impact of higher levels of DOC on drinking water resources, and to provide renewed/sustained interest in DOC research that can encourage interdisciplinary collaboration. Understanding the cycling of carbon from terrestrial ecosystems into natural waters is necessary in the face of a variable and changing climate, as climate change-related mechanisms may become increasingly responsible for variations in the inputs of allochthonous DOC concentrations in water.

4 June 2015 in Nicotine & Tobacco Research
Verified
Journal Article
Open access
PDF file
TPTodd Pagano
Todd Pagano
ADA. Gary DiFrancesco
A. Gary DiFrancesco
SSSusan B. Smith
Susan B. Smith
JGJerrin George
Jerrin George
GWGloria Wink
Gloria Wink
Risa RobinsonRisa Robinson
Risa Robinson
Electronic cigarettes (E-Cigs) are popular alternatives to conventional tobacco cigarettes. Disposable E-Cigs are single-use devices that emit aerosols from a nicotine-containing solution (e-liquid) by activating a heating coil during puffing. However, due to lack of regulations and standards, it is unclear how product claims are aligning with actual content and performance. Some analytical methods for characterizing E-Cigs are still in an exploratory phase. Five products of disposable E-Cigs (purchased March–April, 2014 from a local smoke shop and an on-line US distributor) were studied for nicotine content, number of puffs obtained before depletion, portion of nicotine delivered via aerosolization, and e-liquid pH. Protocols were developed to consistently extract e-liquid from puffed and unpuffed E-Cigs. An in-house mechanical puffing machine was used to consistently puff E-Cig aerosols onto filter pads. A gas chromatography-mass spectrometry method was developed that produced sensitive and repeatable nicotine determinations. Under our experimental parameters, results showed a disparity between nicotine content and number of puffs achieved relative to what was claimed on product packaging. The portion of nicotine delivered to filter pads was often less than half that which was available, indicating much of the nicotine may be left in the E-Cig upon depletion. Analyses of unpuffed E-Cigs by gas chromatography-mass spectrometry indicate the nicotine content of these products can be considerably different from manufacture’s labeling. Furthermore, a large portion of the nicotine in E-Cigs may not be transferred to the user, and that which is transferred, may often be in the less bioavailable form.

1 April 2013 in Northeastern Naturalist
Verified
Journal Article
Closed access
SSSusan B. Smith
Susan B. Smith
SDSamantha A. DeSando
Samantha A. DeSando
TPTodd Pagano
Todd Pagano

NENathan C Eddingsaas
Nathan C Eddingsaas
TPTodd Pagano
Todd Pagano
CCCody Cummings
Cody Cummings
Irfan RahmanIrfan Rahman
Irfan Rahman
Risa RobinsonRisa Robinson
Risa Robinson
Edward HenselEdward Hensel
Edward Hensel
This work investigates emissions sampling methods employed for qualitative identification of compounds in e-liquids and their resultant aerosols to assess what capture methods may be sufficient to identify harmful and potentially harmful constituents present. Three popular e-liquid flavors (cinnamon, mango, vanilla) were analyzed using qualitative gas chromatography-mass spectrometry (GC-MS) in the un-puffed state. Each liquid was also machine-puffed under realistic-use flow rate conditions and emissions were captured using two techniques: filter pads and methanol impingers. GC-MS analysis was conducted on the emissions captured using both techniques from all three e-liquids. The e-liquid GC-MS analysis resulted in positive identification of 13 compounds from the cinnamon flavor e-liquid, 31 from mango, and 19 from vanilla, including a number of compounds observed in all e-liquid experiments. Nineteen compounds were observed in emissions which were not present in the un-puffed e-liquid. Qualitative GC-MS analysis of the emissions samples identify compounds observed in all three samples: e-liquid, impinge, and filter pads, and each subset thereof. A limited number of compounds were observed in emissions captured with impingers, but were not observed in emissions captured using filter pads; a larger number of compounds were observed on emissions collected from the filter pads, but not those captured with impingers. It is demonstrated that sampling methods have different sampling efficiencies and some compounds might be missed using only one method. It is recommended to investigate filter pads, impingers, thermal desorption tubes, and solvent extraction resins to establish robust sampling methods for emissions testing of e-cigarette emissions.

6 August 2020 in Journal of Chemical Education
Verified
Journal Article
Closed access
MLMatthew A. Lynn
Matthew A. Lynn
DTDavid C. Templeton
David C. Templeton
ARAnnemarie D. Ross
Annemarie D. Ross
AGAustin U. Gehret
Austin U. Gehret
MBMorgan Bida
Morgan Bida
TPTodd Pagano
Todd Pagano