William Stoddard

Dr. William Stoddard

Biomedical Engineering, Rochester Institute of Technology, Rochester, Indiana, USA
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2016 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
DSDhananjay Radhakrishnan Subramaniam
Dhananjay Radhakrishnan Subramaniam
William StoddardWilliam Stoddard
William Stoddard
KMKristian H. Mortensen
Kristian H. Mortensen
SRSteffen Ringgaard
Steffen Ringgaard
CTChristian Trolle
Christian Trolle
Iris LittleIris Little
Iris Little
Severity of thoracic aortic disease in Turner syndrome (TS) patients is currently described through measures of aorta size and geometry at discrete locations. The objective of this study is to develop an improved measurement tool that quantifies changes in size and geometry over time, continuously along the length of the thoracic aorta. Cardiovascular magnetic resonance (CMR) scans for 15 TS patients [41 ± 9 years (mean age ± standard deviation (SD))] were acquired over a 10-year period and compared with ten healthy gender and age-matched controls. Three-dimensional aortic geometries were reconstructed, smoothed and clipped, which was followed by identification of centerlines and planes normal to the centerlines. Geometric variables, including maximum diameter and cross-sectional area, were evaluated continuously along the thoracic aorta. Distance maps were computed for TS and compared to the corresponding maps for controls, to highlight any asymmetry and dimensional differences between diseased and normal aortae. Furthermore, a registration scheme was proposed to estimate localized changes in aorta geometry between visits. The estimated maximum diameter from the continuous method was then compared with corresponding manual measurements at 7 discrete locations for each visit and for changes between visits. Manual measures at the seven positions and the corresponding continuous measurements of maximum diameter for all visits considered, correlated highly (R-value = 0.77, P < 0.01). There was good agreement between manual and continuous measurement methods for visit-to-visit changes in maximum diameter. The continuous method was less sensitive to inter-user variability [0.2 ± 2.3 mm (mean difference in diameters ± SD)] and choice of smoothing software [0.3 ± 1.3 mm]. Aortic diameters were larger in TS than controls in the ascending [TS: 13.4 ± 2.1 mm (mean distance ± SD), Controls: 12.6 ± 1 mm] and descending [TS: 10.2 ± 1.3 mm (mean distance ± SD), Controls: 9.5 ± 0.9 mm] thoracic aorta as observed from the distance maps. An automated methodology is presented that enables rapid and precise three-dimensional measurement of thoracic aortic geometry, which can serve as an improved tool to define disease severity and monitor disease progression. ClinicalTrials.gov Identifier - NCT01678274 . Registered - 08.30.2012.

1 January 2015 in AIAA Journal
Verified
Journal Article
Closed access
RDRobert Driscoll
Robert Driscoll
William StoddardWilliam Stoddard
William Stoddard
AGAndrew St. George
Andrew St. George
Ephraim GutmarkEphraim Gutmark
Ephraim Gutmark
An experimental investigation was carried out to study the propagation of a shock wave through a crossover tube for the purpose of causing shock-initiated detonation. A pulse detonation engine was used as a driver source to propagate a shock wave through a crossover tube into a second, adjacent detonation tube (that is, driven). Results showed a transferred shock wave achieved shock-initiated detonation, and for specific crossover tube geometries, there was a maximum effective crossover tube length for which the event was possible. This maximum effective length was strongly correlated to the strength of the transferred shock. Initiation performance in the driven detonation tube declined when the incident shock strength decreased below MS=2.0. Introducing a bend to the end of the crossover tube increased the driven detonation tube initiation performance by enhancing the strength of the transferred planar shock wave by an average of 20%. A numerical investigation on shock wave planar attenuation in a crosso...

15 June 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
NINayeem Imtiaz
Nayeem Imtiaz
MPMatthew D. Poskus
Matthew D. Poskus
William StoddardWilliam Stoddard
William Stoddard
TGThomas Gaborski
Thomas Gaborski
SDSteven W Day
Steven W Day
Microfluidic devices promise to overcome the limitations of conventional hemodialysis and oxygenation technologies by incorporating novel membranes with ultra-high permeability into portable devices with low blood volume. However, the characteristically small dimensions of these devices contribute to both non-physiologic shear that could damage blood components and laminar flow that inhibits transport. While many studies have been performed to empirically and computationally study hemolysis in medical devices, such as valves and blood pumps, little is known about blood damage in microfluidic devices. In this study, four variants of a representative microfluidic membrane-based oxygenator and two controls (positive and negative) are introduced, and computational models are used to predict hemolysis. The simulations were performed in ANSYS Fluent for nine shear stress-based parameter sets for the power law hemolysis model. We found that three of the nine tested parameters overpredict (5 to 10×) hemolysis compared to empirical experiments. However, three parameter sets demonstrated higher predictive accuracy for hemolysis values in devices characterized by low shear conditions, while another three parameter sets exhibited better performance for devices operating under higher shear conditions. Empirical testing of the devices in a recirculating loop revealed levels of hemolysis significantly lower (10 ppm). Evaluating the model’s ability to predict hemolysis across diverse shearing conditions, both through empirical experiments and computational validation, will provide valuable insights for future micro ECMO device development by directly relating geometric and shear stress with hemolysis levels. We propose that, with an informed selection of hemolysis parameters based on the shear ranges of the test device, computational modeling can complement empirical testing in the development of novel high-flow blood-contacting microfluidic devices, allowing for a more efficient iterative design process. Furthermore, the low device-induced hemolysis measured in our study at physiologically relevant flow rates is promising for the future development of microfluidic oxygenators and dialyzers.

28 May 2025 in Biomedical Microdevices
Verified
Journal Article
Open access
PDF file
NINayeem Imtiaz
Nayeem Imtiaz
William StoddardWilliam Stoddard
William Stoddard
AGAbdelrahman Ghazy
Abdelrahman Ghazy
SDSteven W Day
Steven W Day
Extracorporeal Membrane Oxygenation (ECMO) serves as a crucial intervention for patients with severe pulmonary dysfunction by facilitating oxygenation and carbon dioxide removal. While traditional ECMO systems are effective, their large priming volumes and significant blood-contacting surface areas can lead to complications, particularly in neonates and pediatric patients. Microfluidic ECMO systems offer a promising alternative by miniaturizing the ECMO technology, reducing blood volume requirements, and minimizing device surface area to improve safety and efficiency. This study investigates the oxygen transport performance of three membrane types— polydimethylsiloxane (PDMS), polypropylene, and a novel nanoporous silicon nitride (NPSiN) membrane—in a microfluidic ECMO platform. While nanoporous membranes rely on pore-mediated diffusion and PDMS on polymer lattice diffusion, results show no significant differences in device oxygenation efficiency (p > 0.05). Blood-side factors, including the diffusion rate of oxygen through the red blood cell (RBC) membrane, RBC residence time, and hemoglobin binding kinetics, were identified as primary bottlenecks. Even computational models of a hypothetical infinitely permeable membrane corroborate the limited impact of membrane material. These findings suggest a shift in ECMO design priorities from membrane material to blood-side enhancements. This research provides a foundation for optimizing ECMO systems.

1 December 2015 in AIAA Journal
Verified
Journal Article
Closed access
RDRobert Driscoll
Robert Driscoll
AGAndrew St. George
Andrew St. George
William StoddardWilliam Stoddard
William Stoddard
DMDavid Munday
David Munday
Ephraim GutmarkEphraim Gutmark
Ephraim Gutmark
Shock wave propagation within a pulse detonation engine–crossover system is investigated, examining the properties and mechanisms of the transfer process. A shock wave is transferred through a crossover tube that connects a spark-ignited driver pulse detonation engine to a secondary, driven pulse detonation engine. Detonations in the driven pulse detonation engine develop from shock-initiated combustion, as strong shock wave reflection can cause ignition within a reactive mixture. A pulse detonation engine–crossover system can decrease deflagration-to-detonation transition length while employing a single spark source to initiate a system consisting of multiple detonation engines. Visualization of a shock wave propagating through a clear channel reveals a complex shock train behind the leading shock wave. Transverse waves connect with the leading shock wave to form a triple point that oscillates through the leading shock wave. The shock wave Mach number and decay rate remain constant for varying crossover tube geometries and operational frequencies. A temperature gradient forms within the crossover tube due to forward flow of high-temperature ionized gas into the crossover tube from the driver pulse detonation engine and backward flow of ionized gas into the crossover tube from the driven pulse detonation engine. This communication results in intermittent autoignition of the driver pulse detonation engine for higher-frequency large-crossover-tube-diameter cases. However, small-diameter crossover tubes prevent these autoignition events at higher frequencies.

25 July 2014
Verified
Conference Paper
Closed access
William StoddardWilliam Stoddard
William Stoddard
AGAndrew C. St. George
Andrew C. St. George
RDRobert B. Driscoll
Robert B. Driscoll
Ephraim GutmarkEphraim Gutmark
Ephraim Gutmark