Microfluidic devices promise to overcome the limitations of conventional hemodialysis and oxygenation technologies by incorporating novel membranes with ultra-high permeability into portable devices with low blood volume. However, the characteristically small dimensions of these devices contribute to both non-physiologic shear that could damage blood components and laminar flow that inhibits transport. While many studies have been performed to empirically and computationally study hemolysis in medical devices, such as valves and blood pumps, little is known about blood damage in microfluidic devices. In this study, four variants of a representative microfluidic membrane-based oxygenator and two controls (positive and negative) are introduced, and computational models are used to predict hemolysis. The simulations were performed in ANSYS Fluent for nine shear stress-based parameter sets for the power law hemolysis model. We found that three of the nine tested parameters overpredict (5 to 10×) hemolysis compared to empirical experiments. However, three parameter sets demonstrated higher predictive accuracy for hemolysis values in devices characterized by low shear conditions, while another three parameter sets exhibited better performance for devices operating under higher shear conditions. Empirical testing of the devices in a recirculating loop revealed levels of hemolysis significantly lower (10 ppm). Evaluating the model’s ability to predict hemolysis across diverse shearing conditions, both through empirical experiments and computational validation, will provide valuable insights for future micro ECMO device development by directly relating geometric and shear stress with hemolysis levels. We propose that, with an informed selection of hemolysis parameters based on the shear ranges of the test device, computational modeling can complement empirical testing in the development of novel high-flow blood-contacting microfluidic devices, allowing for a more efficient iterative design process. Furthermore, the low device-induced hemolysis measured in our study at physiologically relevant flow rates is promising for the future development of microfluidic oxygenators and dialyzers.
The cerebral artery system can be affected by various diseases such as stroke, carotid stenosis, vertebral stenosis, intracranial stenosis, aneurysms, and vascular malformations. Understanding the blood flow specific to each patient's cerebral arteries can provide crucial information about how these diseases progress and guide potential treatment options. A patient-specific Magnetic Resonance Imaging (MRI) scan of a human brain was utilized to create a 3D model of the arterial system. Blood flow simulations were conducted using the ANSYS (Fluent) R2021 software package. The ICEM meshing tool within the ANSYS software was employed to prepare the models. The velocity rise and pressure drop were observed in the branching of the basilar artery. This can provide valuable patient specific information on various cerebral diseases, and drug delivery cases. The non-Newtonian properties of blood were established by inputting the Power Law parameters into the ANSYS Fluent system. It was observed that the effects of non-Newtonian properties of blood are relatively negligible for the large vessels studied (> 200 um).
Extracorporeal Membrane Oxygenation (ECMO) serves as a crucial intervention for patients with severe pulmonary dysfunction by facilitating oxygenation and carbon dioxide removal. While traditional ECMO systems are effective, their large priming volumes and significant blood-contacting surface areas can lead to complications, particularly in neonates and pediatric patients. Microfluidic ECMO systems offer a promising alternative by miniaturizing the ECMO technology, reducing blood volume requirements, and minimizing device surface area to improve safety and efficiency. This study investigates the oxygen transport performance of three membrane types— polydimethylsiloxane (PDMS), polypropylene, and a novel nanoporous silicon nitride (NPSiN) membrane—in a microfluidic ECMO platform. While nanoporous membranes rely on pore-mediated diffusion and PDMS on polymer lattice diffusion, results show no significant differences in device oxygenation efficiency (p > 0.05). Blood-side factors, including the diffusion rate of oxygen through the red blood cell (RBC) membrane, RBC residence time, and hemoglobin binding kinetics, were identified as primary bottlenecks. Even computational models of a hypothetical infinitely permeable membrane corroborate the limited impact of membrane material. These findings suggest a shift in ECMO design priorities from membrane material to blood-side enhancements. This research provides a foundation for optimizing ECMO systems.
Extracorporeal Membrane Oxygenation (ECMO) serves as a crucial intervention for patients with severe pulmonary dysfunction by facilitating oxygenation and carbon dioxide removal. While traditional ECMO systems are effective, their large priming volumes and significant blood-contacting surface areas can lead to complications, particularly in neonates and pediatric patients. Microfluidic ECMO systems offer a promising alternative by miniaturizing the ECMO technology, reducing blood volume requirements, and minimizing device surface area to improve safety and efficiency. This study investigates the oxygen transport performance of three membrane types— polydimethylsiloxane (PDMS), polypropylene, and a novel nanoporous silicon nitride (SiN) membrane—in a microfluidic ECMO platform. While nanoporous membranes rely on pore-mediated diffusion and PDMS on polymer lattice diffusion, results show no significant differences in device oxygenation efficiency (p > 0.05). Blood-side factors, including the diffusion rate of oxygen through the red blood cell (RBC) membrane, RBC residence time, and hemoglobin binding kinetics, were identified as primary bottlenecks. Even computational models of a hypothetical infinitely permeable membrane corroborate the limited impact of membrane material. These findings suggest a shift in ECMO design priorities from membrane material to blood-side enhancements. This research provides a foundation for optimizing ECMO systems.