Poonam Arora

Dr. Poonam Arora

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2013 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
PAPoonam Arora
Poonam Arora
SPSubhajit Banerjee Purnapatra
Subhajit Banerjee Purnapatra
AAAishik Acharya
Aishik Acharya
AAAshish Agarwal
Ashish Agarwal
SYSuchi Yadav
Suchi Yadav
AGAmitava Sen Gupta
Amitava Sen Gupta
National Physical Laboratory India has developed a cesium atomic fountain frequency standard. The fountain has now become operational and is ready for complete frequency evaluation. In this paper, we report for the first time, the preliminary results obtained with this fountain, which include Ramsey fringes, frequency stability analysis, with an H-maser, and magnetic field mapping in the atomic flight region.

19 February 2014 in Pramana
Verified
Journal Article
Closed access
PDF file
PAPoonam Arora
Poonam Arora
AAAmrita Awasthi
Amrita Awasthi
VBVattikonda Bharath
Vattikonda Bharath
AAAishik Acharya
Aishik Acharya
SYSuchi Yadav
Suchi Yadav
AGAmitava Sen Gupta
Amitava Sen Gupta

10 October 2018 in Current Science
Verified
Journal Article
Open access
LSLAKHI SHARMA
LAKHI SHARMA
SDS. De
S. De
PKP. Kandpal
P. Kandpal
MOM. P. Olaniya
M. P. Olaniya
SYSanjay Yadav
Sanjay Yadav
DADinesh K Aswal
Dinesh K Aswal


24 August 2023
Verified
Book Chapter
Closed access
PDF file
PAPoonam Arora
Poonam Arora
AGAmitava Sen Gupta
Amitava Sen Gupta

27 March 2025 in Atoms
Verified
Journal Article
Open access
PDF file
ABAnjali Bisht
Anjali Bisht
MDManoj Das
Manoj Das
PAPoonam Arora
Poonam Arora
Sub-Doppler laser-cooled cesium-133 atoms are utilized as quantum sensors to achieve precise mapping of magnetic fields across a region in ultra-high vacuum (UHV), with a spatial resolution of 1 cm and a sensitivity of approximately 550 pT/√Hz, enabling accurate measurements within the nanotesla [nT] range. The cold cesium-133 atoms used for magnetic field measurements in this paper are a key component of the cesium fountain frequency standard at CSIR-NPL, which contributes to both timekeeping and magnetic sensing. The results show magnetic field fluctuations within 1 nT with a spatial resolution of 1 cm. The uncertainty in these measurements is of the order of 1.24 × 10−16, ensuring reliable and precise spatially resolved magnetic field mapping.