The flow field structure and pressure pulsation characteristics in two series of trailing edges of a centrifugal pump are investigated using the SST k-w turbulence model. Series 1 involves varying the impeller exit angle, and Series 2 involves varying the impeller exit shape. The entropy generation rate analysis method is used to evaluate the numerical simulation results. Vortex cores within the flow field are identified by applying the Ω criterion. The influence of different trailing edge configurations on the energy loss characteristics of the pumps is explored. The dynamic mode decomposition (DMD) method is used to analyze pressure pulsations at the volute considering unsteady flows in centrifugal pumps with different trailing edge shapes. The findings suggest that different trailing edge shapes can be used to adjust the energy loss proportions in various components of the pump. In Series 1, the efficiency remains nearly constant with changes in the outlet angle on both sides of the trailing edge. In Series 2, the efficiency is enhanced by 1.18% with the elliptical edge shape on both sides (EBS) compared to the original trailing edge (OTE) shape. In Series 1 and Series 2, greater entropy generation rates are accompanied by greater pressure pulsations at the pump outlet. The DMD results demonstrate a noticeable impact of the different trailing edges on the pressure distribution of various modes within the volute. Moreover, the impeller outlet pressure inhomogeneity coefficient changes under different modes. This study holds great significance for selecting the appropriate trailing edges for centrifugal pumps.
A novel split‐type air conditioning system is introduced to balance usability and portability. Unlike conventional split‐type systems, where the compressor is typically placed outside, this system situates the compressor within the indoor unit, which may expose users to compressor noise. There are prominent peaks in the compressor noise spectrum, particularly at the compressor operating frequency and its harmonics, notably the second and third harmonics. The research presents a multilayered acoustic enclosure specifically designed for air conditioning compressors to address this issue without modifying the compressor or indoor unit casing. In order to get better sound insulation performance, a response surface methodology (RSM) is applied to optimize the thickness ratio, open area ratio, and open area height of the acoustic enclosure with predefined thickness. In addition, topological optimization is employed to strengthen weak areas of the acoustic enclosure. Then, experimental trials using the proposed acoustic enclosure are conducted in a semianechoic chamber. Results demonstrate significant reductions in noise levels, including 7.99 dB(A), 5.69 dB(A), and 5.19 dB(A) reductions in the fundamental frequency, second harmonic, and third harmonic noise of the compressor’s operating frequency, respectively.
This study investigates the flow-induced vibration (FIV) and heat transfer behavior of three heated cylinders arranged in an isosceles triangle configuration at a Reynolds number of 100. A dynamic model for the FIV of two-dimensional, elastically supported cylinders was developed using computational fluid dynamics simulations and overset mesh technology. The effects of aspect ratio (AR) and angle of attack (α) were examined by varying α from 30° to 90° and AR from 0.75 to 2.0, with AR = 1.0 corresponding to a circular cross section. To study FIV, the two-degree-of-freedom motion of the cylinders was analyzed across a range of reduced velocities (Ur = 2–12). The results indicate that as α increases, the impact of the upstream cylinder's wake on the downstream cylinders gradually weakens, resulting in lower vibration amplitudes and higher heat transfer rates for the downstream cylinders. Notably, when α reaches 90°, the streamwise amplitude becomes almost negligible. At α = 30° and 45°, the average Nusselt number of the downstream cylinder is generally lower than that of the upstream cylinder. However, when α reaches 60°, the average Nusselt number of the downstream cylinders becomes noticeably higher than that of the upstream cylinder. As the aspect ratio increases, the lock-in region of the cylinders shifts from being concentrated at Ur = 6 and 8 to Ur = 4 and 6, indicating that the increase in aspect ratio raises the vortex shedding frequency.
This study employs the dynamic sliding multi-region and the Reynolds averaged Navier–Stokes to conduct computational fluid dynamics numerical simulations on the centrifugal pump flow characteristics under four forms of impeller whirling vibrations. The influence mechanisms of different whirling forms on the unsteady flow characteristics and rotor–stator interaction are analyzed. Because of assembly errors and non-uniform support stiffness, the centrifugal pump impeller does not undergo simple eccentric rotation. Instead, it exhibits the complex whirling vibration with multiple kinematic characteristics, which has been neglected in previous studies. First, the numerical models of different whirling vibration forms are established to simulate the unsteady flow characteristics. The accuracy is verified using the test bench. Second, the study investigates the influence mechanisms of different whirling vibration forms on the flow characteristics and rotor–stator interaction. The results demonstrate that the rotor–stator interaction can be categorized into small-scale interaction from the single blade and large-scale interaction from the overall impeller under whirling conditions. The additional fluctuations caused by whirling vibration result from periodic variations in the magnitude and direction of the impeller outflow velocity. Under backward whirling, the modulation frequency amplitude of the flow characteristics is greater. This is because the high tangential speed region of the impeller is opposite to the whirling direction, thereby intensifying the unsteady flow characteristics caused by rotor–stator interaction. This study serves as a foundation for vibration and noise control and fault diagnosis of centrifugal pumps.