Lieyi Dong

Lieyi Dong

Auto-generated profile, based on publicly available information

Lieyi Dong

College of Power and Energy Engineering, Harbin Engineering University, Harbin, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 December 2024 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
QWQi Wei
Qi Wei
LDLieyi Dong
Lieyi Dong
WLWanyou Li
Wanyou Li
DZDepeng Zeng
Depeng Zeng
The utilization of inverters and pulse width modulation (PWM) technology in driving permanent magnet synchronous motors (PMSMs) introduces high-frequency sideband electromagnetic force. Consequently, the risk of PMSMs resonance inevitably increases, leading to disruptions in the operating state and increased noise radiation. Two-dimensional (2-D) sideband electromagnetic force, torque ripple, and electromagnetic vibration of PMSMs with integral-slot and fractional-slot winding arrangements are studied in this article. The torque ripple caused by sideband harmonic currents is derived. Rules to reduce electromagnetic vibration are proposed. The results indicate that the sideband electromagnetic forces have both low- and high-frequency characteristics. Torque ripple shows a new high-frequency characteristic. Experimental findings validate the effectiveness of the proposed rules for optimizing electromagnetic vibration, resulting in an 11.1 dB reduction in the 3.5–6.5 kHz band.

1 November 2024 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
ZLZhiqiang Li
Zhiqiang Li
XWXi Wang
Xi Wang
ZWZhiguo Wei
Zhiguo Wei
YCYuxuan Chen
Yuxuan Chen
ZSZhengkai Song
Zhengkai Song
CJChen-Xing Jiang
Chen-Xing Jiang
This study investigates the flow-induced vibration (FIV) and heat transfer behavior of three heated cylinders arranged in an isosceles triangle configuration at a Reynolds number of 100. A dynamic model for the FIV of two-dimensional, elastically supported cylinders was developed using computational fluid dynamics simulations and overset mesh technology. The effects of aspect ratio (AR) and angle of attack (α) were examined by varying α from 30° to 90° and AR from 0.75 to 2.0, with AR = 1.0 corresponding to a circular cross section. To study FIV, the two-degree-of-freedom motion of the cylinders was analyzed across a range of reduced velocities (Ur = 2–12). The results indicate that as α increases, the impact of the upstream cylinder's wake on the downstream cylinders gradually weakens, resulting in lower vibration amplitudes and higher heat transfer rates for the downstream cylinders. Notably, when α reaches 90°, the streamwise amplitude becomes almost negligible. At α = 30° and 45°, the average Nusselt number of the downstream cylinder is generally lower than that of the upstream cylinder. However, when α reaches 60°, the average Nusselt number of the downstream cylinders becomes noticeably higher than that of the upstream cylinder. As the aspect ratio increases, the lock-in region of the cylinders shifts from being concentrated at Ur = 6 and 8 to Ur = 4 and 6, indicating that the increase in aspect ratio raises the vortex shedding frequency.

21 March 2025 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
QWQi Wei
Qi Wei
LDLieyi Dong
Lieyi Dong
WLWanyou Li
Wanyou Li
Mauro AndriolloMauro Andriollo
Mauro Andriollo
DZDepeng Zeng
Depeng Zeng
In order to study the electromagnetic vibration and torque ripple of multi-unit permanent magnet synchronous motors (PMSMs), an analytical model of flux density under multi-unit operation was established. The spatiotemporal characteristics of 2-D air-gap flux density, electromagnetic force, and electromagnetic torque were explored, and the characteristics of electromagnetic force and vibration response under unit-missing operation were analyzed. First, the flux density analytical models under the operation of one unit and k unit motors were established, and the spatiotemporal distribution law of electromagnetic force and electromagnetic torque was analyzed. Then, the vibration response under unit-missing operation was theoretically derived and analyzed; finally, the prototype was simulated and experimentally verified. With k unit motors, the electromagnetic force and torque components exhibit harmonics with angular frequency $2\pi (2hf_{e})$ and $2\pi (6hf_{e})$ , $h\in \mathbb {N}$ , respectively ( $f_{e}$ supply line frequency). The unbalanced electromagnetic pull resulting from the lack of a single unit introduces additional force harmonics, whose frequencies differ from those in balanced operation by multiples of the rotation frequency $f_{r}=f_{e}/p$ (p: pole pairs) that, however, are not generally multiples of $f_{e}$ .

8 January 2026 in Measurement
Verified
Journal Article
Closed access
LDLieyi Dong
Lieyi Dong
QWQi Wei
Qi Wei
DZDepeng Zeng
Depeng Zeng
WLWanyou Li
Wanyou Li
Mauro AndriolloMauro Andriollo
Mauro Andriollo
ZSZhijun Shuai
Zhijun Shuai

1 August 2026 in Physics of Fluids
Verified
Journal Article
Closed access
JHJiaxuan He
Jiaxuan He
WLWanyou Li
Wanyou Li
ZLZhixiang Li
Zhixiang Li
ZSZhijun Shuai
Zhijun Shuai
LDLieyi Dong
Lieyi Dong
This study investigates the influence of impeller translation on the internal flow of a centrifugal pump, with a focus on how translation-induced effects redistribute flow structures and modulate unsteady characteristics. Non-concentric impeller motion represents a critical off-design condition that exacerbates pressure pulsations and unsteady radial forces, increasing shaft stress and the risk of fatigue failure. Therefore, it is essential for operational reliability to characterize the interplay between impeller translation and the evolution of the internal flow. A computational fluid dynamics framework for generalized impeller eccentric rotation is proposed to capture this motion, employing a vibration intensity number (VIN) to quantify different eccentric operating conditions. The radial force, outlet pressure spatiotemporal evolution, and relative velocity fields are systematically analyzed. In addition, dynamic mode decomposition (DMD) is applied to identify the corresponding frequency-domain flow features. The results demonstrate that impeller translation significantly alters the radial force and the spatiotemporal evolution of the outlet pressure. Specifically, the outlet pressure exhibits distinct low-frequency, high-pressure propagation features, whose direction, phase relation, and circumferential distribution vary with the translational state. Mechanistically, the pressure field is governed by a coupled dual effect of kinematic and dynamic influences. Under bi-directional translation, the final pressure pattern is determined by the dominant directional component when these effects are in opposition. For the VIN = 1 case, the fixed relationship between translational velocity and acceleration produces a highly ordered evolution of flow variables. The DMD results further confirm this flow reorganization in the frequency domain. In particular, impeller translation modifies the harmonics of shaft-frequency pressure modes within the impeller while inducing a strong shaft-frequency response superimposed on the stable blade-passing frequency in the volute. Overall, eccentric motion does not introduce new flow structures; instead, it reshapes the spatiotemporal organization and frequency response of the internal flow through the coupling of rotational motion with translation-induced effects. These findings provide physical insight into flow instability and vibration response under non-concentric pump operation.

7 July 2026 in Mechanical Systems and Signal Processing
Verified
Journal Article
Closed access
YZYi Zhou
Yi Zhou
LDLieyi Dong
Lieyi Dong
ZSZhijun Shuai
Zhijun Shuai