Safarov Farit

Dr. Safarov Farit

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2013 in Russian Journal of Bioorganic Chemistry
Verified
Journal Article
Closed access
PDF file
OKOxana Kazakova
Oxana Kazakova
ISIrina E. Smirnova
Irina E. Smirnova
HTH. Do Tkhi Tkhu
H. Do Tkhi Tkhu
TNTkhankh Tra Nguen
Tkhankh Tra Nguen
GAG. N. Apryshko
G. N. Apryshko
GTG. A. Tolstikov
G. A. Tolstikov
The synthesis of (7 R,8 S)-epoxy-(13 R,17 R)-trioxolane abietic acid was carried out and its structure was established by X-ray diffraction. The antineoplastic activity and the ability to induce...

22 December 2024 in Gels
Verified
Journal Article
Open access
PDF file
ATAleksey Telin
Aleksey Telin
SFSafarov Farit
Safarov Farit
RYRavil Yakubov
Ravil Yakubov
EGEkaterina Gusarova
Ekaterina Gusarova
APArtem Pavlik
Artem Pavlik
VDVladimir Dokichev
Vladimir Dokichev
The application of nanocomposites based on polyacrylamide hydrogels as well as silica nanoparticles in various tasks related to the petroleum industry has been rapidly developing in the last 10–15 years. Analysis of the literature has shown that the introduction of nanoparticles into hydrogels significantly increases their structural and mechanical characteristics and improves their thermal stability. Nanocomposites based on hydrogels are used in different technological processes of oil production: for conformance control, water shutoff in production wells, and well killing with loss circulation control. In all these processes, hydrogels crosslinked with different crosslinkers are used, with the addition of different amounts of nanoparticles. The highest nanoparticle content, from 5 to 9 wt%, was observed in hydrogels for well killing. This is explained by the fact that the volumes of injection of block packs are counted only in tens of cubic meters, and for the sake of trouble-free workover, it is very important to preserve the structural and mechanical properties of block packs during the entire repair of the well. For water shutoff, the volumes of nanocomposite injection, depending on the well design, are from 50 to 150 m3. For conformance control, it is required to inject from one to several thousand cubic meters of hydrogel with nanoparticles. Naturally, for such operations, service companies try to select compositions with the minimum required nanoparticle content, which would ensure injection efficiency but at the same time would not lose economic attractiveness. The aim of the present work is to develop formulations of nanocomposites with increased structural and mechanical characteristics based on hydrogels made of partially hydrolyzed polyacrylamide crosslinked with resorcinol and paraform, with the addition of commercially available nanosilica, as well as to study their thermal degradation, which is necessary to predict the lifetime of gel shields in reservoir conditions. Hydrogels with additives of pyrogenic (HCSIL200, HCSIL300, RX380) and hydrated (white carbon black grades: ‘BS-50’, ‘BS-120 NU’, ‘BS-120 U’) nanosilica have been studied. The best samples in terms of their structural and mechanical properties have been established: nanocomposites with HCSIL200, HCSIL300, and BS-120 NU. The addition of hydrophilic nanosilica HCSIL200 in the amount of 0.4 wt% to a hydrogel consisting of partially hydrolyzed polyacrylamide (1%), resorcinol (0.04%), and paraform (0.09%) increased its elastic modulus by almost two times and its USS by almost three times. The thermal degradation of hydrogels was studied at 140 °C, and the experimental time was converted to the exposure time at 80 °C using Van’t Hoff’s rule. It was found that the nanocomposite with HCSIL200 retains its properties at a satisfactory level for 19 months. Filtration studies on water-saturated fractured reservoir models showed that the residual resistance factor and selectivity of the effect of nanocomposites with HCSIL200 on fractures are very high (226.4 and 91.6 for fracture with an opening of 0.05 cm and 11.0 for porous medium with a permeability of 332.3 mD). The selectivity of the isolating action on fractured intervals of the porous formation was noted.

11 November 2011 in RSC Advances
Verified
Journal Article
Closed access
PDF file
DKD. V. Kazakov
D. V. Kazakov
ATA. R. Timerbaev
A. R. Timerbaev
SFSafarov Farit
Safarov Farit
TNT. I. Nazirov
T. I. Nazirov
OKOxana Kazakova
Oxana Kazakova
WAW. Adam
W. Adam
The 1,2,4-trioxolane and 1,2,4,5-tetroxane pharmacophores are currently considered as the next generation of synthetic antimalarial drugs. This fact has stimulated the exploration of the chemiluminescence displayed by these cyclic peroxides in biomimetic reactions with Fe(II). The CL has been induced by FeSO4 and/or the FeCl3/L-cysteine/Rhodamine G system in aqueous (50%) acetonitrile. The light emission in the visible spectral region has been recorded for triterpenoid-based 1,2,4-trioxolanes, purely synthetic ozonide OZ03, bicyclic 1,2,4,5-tetroxanes, a tetroxane derived from deoxycholic acid, the diperoxide of trifluoroacetone, as well as the natural artemisinin. The herein discovered CL provides a promising perspective for the study of pharmacologically active peroxides in biomedical applications.

29 September 2014 in Photochemical & Photobiological Sciences
Verified
Journal Article
Closed access
PDF file
DKDmitri V. Kazakov
Dmitri V. Kazakov
SFSafarov Farit
Safarov Farit
Decomposition of 1,4-dimethylnaphthalene endoperoxide, which is the source of singlet oxygen, in the presence of β-diketonates of europium(III), neodymium(III) and ytterbium(III) is accompanied by bright chemiluminescence (CL) in visible and near infra-red spectral region due to characteristic emission from the lanthanides at λmax = 615 and 710 nm (5D0→7F2 and 5D0→7F4 transitions of Eu3+), 900 nm (4F3/2→4I9/2 transition of Nd3+) and 1000 nm (2F5/2→2F7/2 transition of Yb3+). Singlet oxygen is the key intermediate responsible for the observed CL, which is presumably generated by the reaction of 1O2 with ligands of the complexes. The CL phenomenon discovered herein paves the way towards the development of lanthanide-based CL probe for 1O2.

4 September 2025 in Energies
Verified
Journal Article
Open access
PDF file
Valery MeshalkinValery Meshalkin
Valery Meshalkin
RARustem Asadullin
Rustem Asadullin
SVSergey Vezhnin
Sergey Vezhnin
Alexander VoloshinAlexander Voloshin
Alexander Voloshin
RGRida Gallyamova Gallyamova
Rida Gallyamova Gallyamova
RYRavil Yakubov
Ravil Yakubov
Well-killing operations in water-sensitive hydrophilic formations are often complicated by extended well clean-up periods and, in some cases, failure to restore the well’s production potential post-kill. Typical development targets exhibiting these properties include the Neocomian and Jurassic deposits of fields in Western Siberia and Western Kazakhstan. This paper proposes a well-killing method incorporating simultaneous near-wellbore treatment. In cases where heavy oil components (asphaltenes, resins, or paraffins) are deposited in the near-wellbore zone, their removal with a solvent results in post-operation flow rates that exceed pre-restoration levels. For wells not affected by asphaltene, resin, and paraffin deposits, killing is performed using a blocking pill of invert emulsion stabilized with an emulsifier and hydrophobic nanosilica. During filtration into the formation, this emulsion does not break but rather reforms according to the pore throat sizes. Flow rates in such wells typically match pre-restoration levels. The described engineering solution proves less effective when the well fluid water cut exceeds 60%. For wells exhibiting premature water breakthrough that have not yet produced their estimated oil volume, the water source is identified, and water shutoff operations are conducted. This involves polymer-gel systems crosslinked with resorcinol and paraform, reinforced with inorganic components such as chrysotile microdispersions, micro- and nanodispersions of shungite mineral, and gas black. Oscillation testing identified the optimal additive concentration range of 0.6–0.7 wt%, resulting in a complex modulus increase of up to 25.7%. The most effective polymer-inorganic composite developed by us, incorporating gas black, demonstrates high water shutoff capability (residual resistance factor ranges from 12.5 to 65.0 units within the permeability interval of 151.7 to 10.5 mD). Furthermore, the developed composites exhibit the ability to selectively reduce water permeability disproportionately more than oil permeability. Filtration tests confirmed that the residual permeability to oil after placing the blocking composition with graphene is 6.75 times higher than that to water. Consequently, such treatments reduce the well water cut. Field trials confirmed the effectiveness of the developed polymer-inorganic composite systems.

1 June 2025 in Polymers
Verified
Journal Article
Open access
PDF file
ATAleksey Telin
Aleksey Telin
RYRavil Yakubov
Ravil Yakubov
APArtem Pavlik
Artem Pavlik
VDVladimir Dokichev
Vladimir Dokichev
RGRida Gallyamova Gallyamova
Rida Gallyamova Gallyamova
LLLyubov Lenchenkova
Lyubov Lenchenkova
The challenge of water shutoff in carbonate reservoirs is complicated by the presence of fractures, which cannot be effectively blocked using conventional hydrogel screens designed for granular reservoirs. To reliably seal fractures, fibrous and dispersed fillers are added to hydrogels. These fillers must exhibit affinity for the matrix to ensure the composites can effectively isolate water. Given the wide variability in fracture apertures, it is evident that water shutoff composites should incorporate fibers and dispersed fillers of varying geometric sizes. This study presents a range of hydrogel composites reinforced with mono-, bi-, and tri-component fibers, as well as dispersed fillers, designed for water shutoff in fractured carbonate reservoirs with varying fracture apertures. Oscillation test results demonstrated a twofold increase in the elastic modulus (40–45 Pa) for compositions with various fillers compared to the base composition (23 Pa). Filtration studies revealed the effectiveness of the optimized compositions under different fracture apertures. Specifically, even at a fracture aperture of 650 μm, the residual resistance factor (RRF) reached 82.3 and 9.76 at water flow rates of 0.1 cm3/min and 0.5 cm3/min, respectively. The conducted rheological and filtration tests, along with field trials, confirmed the validity of the selected approach.