Claudius Melzig

Dr. Claudius Melzig

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2019 in European Radiology
Verified
Journal Article
Closed access
PDF file
CMClaudius Melzig
Claudius Melzig
SWStefan Wörz
Stefan Wörz
BEBenjamin Egenlauf
Benjamin Egenlauf
SPSasan Partovi
Sasan Partovi
KRKarl Rohr
Karl Rohr
Fabian RengierFabian Rengier
Fabian Rengier

10 March 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
MFMatthias Alexander Fink
Matthias Alexander Fink
SSSibylle Stoll
Sibylle Stoll
CMClaudius Melzig
Claudius Melzig
ASAndrea Steuwe
Andrea Steuwe
SPSasan Partovi
Sasan Partovi
Fabian RengierFabian Rengier
Fabian Rengier
The purpose of this study was to prospectively analyse image quality and radiation dose of body mass index (BMI)-adapted low-radiation and low-iodine dose CTA of the thoracoabdominal aorta in obese and non-obese patients. This prospective, single-centre study included patients scheduled for aortic CTA between November 2017 and August 2020 without symptoms of high-grade heart failure. A BMI-adapted protocol was used: Group A/Group B, BMI < 30/≥ 30 kg/m2, tube potential 80/100 kVp, total iodine dose 14.5/17.4 g. Intraindividual comparison with the institutional clinical routine aortic CTA protocol was performed. The final study cohort comprised 161 patients (mean 71.1 ± 9.4 years, 32 women), thereof 126 patients in Group A (mean BMI 25.4 ± 2.8 kg/m2) and 35 patients in Group B (34.0 ± 3.4 kg/m2). Mean attenuation over five aortoiliac measurement positions for Group A/B was 354.9 ± 78.2/262.1 ± 73.0 HU. Mean effective dose for Group A/B was 3.05 ± 0.46/6.02 ± 1.14 mSv. Intraindividual comparison in 50 patients demonstrated effective dose savings for Group A/B of 34.4 ± 14.5/25.4 ± 14.1% (both p < 0.001), and iodine dose savings for Group A/B of 54/44.8%. Regression analysis showed that female sex and increasing age were independently associated with higher vascular attenuation. In conclusion, BMI-adapted, low-radiation and low-iodine dose CTA of the thoracoabdominal aorta delivers diagnostic image quality in non-obese and obese patients without symptoms of high-grade heart failure, with superior image quality in females and the elderly.

6 July 2024 in European Journal of Radiology
Verified
Journal Article
Open access
TDThuy D Do
Thuy D Do
SRS. Rahn
S. Rahn
CMClaudius Melzig
Claudius Melzig
CHC.P. Heußel
C.P. Heußel
WSW. Stiller
W. Stiller
SSS. Skornitzke
S. Skornitzke
To evaluate a novel calcium-only imaging technique (VCa) with subtracted bone marrow in osteoporosis in dual-layer CT (DLCT) compared to conventional CT images (CI) and dual-energy X-ray absorptiometry (DXA). Images of a multi-energy CT phantom with calcium inserts, quantitative CT calibration phantom, and of 55 patients (mean age: 64.6 ± 11.5 years) were acquired on a DLCT to evaluate bone mineral density (BMD). CI, calcium-suppressed images, and VCa were calculated. For investigating the association of VCa and CI with DXA a subsample of 30 patients (<90 days between DXA and CT) was used. Multiple regression analysis was performed to identify further factors improving the prediction of DXA BMD. The calcium concentrations of the CT phantom inserts were significantly associated with CT numbers from VCa (R2 = 0.94) and from CI (R2 = 0.89-0.92). VCa showed significantly higher CT numbers than CI in the phantom (p ≤ 0.001) and clinical setting (p < 0.001). CT numbers from VCa were significantly associated with CI (R2 = 0.95, p < 0.001) and with DXA (R2 = 0.31, p = 0.007), whereas no significant association between DXA and CI was found. Prediction of DXA BMD based on CT numbers derived from VCa yielded R2 = 0.76 in multiple regression analysis. ROC for the differentiation of normal from pathologic BMD in VCa yielded an AUC of 0.7, and a cut-off value of 126HU (sensitivity: 0.90; specificity: 0.47). VCa images showed better agreement with DXA and known calcium concentrations than CI, and could be used to estimate BMD. A VCa cut-off of 126HU could be used to identify abnormal bone mineral density.

24 April 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
CSChristopher Schuppert
Christopher Schuppert
JSJanek Salatzki
Janek Salatzki
FAFlorian Andre
Florian Andre
JRJohannes Riffel
Johannes Riffel
DMDavid L. Mangold
David L. Mangold
TDThuy D Do
Thuy D Do
Reduced iodine loads for computed tomography (CT)-based vascular assessment prior to transcatheter aortic valve implantation (TAVI) may be feasible in conjunction with a spectral detector CT scanner. This prospective single-center study considered 100 consecutive patients clinically referred for pre-TAVI CT. They were examined on a dual-layer detector CT scanner to obtain an ECG-gated cardiac scan and a non-ECG-gated aortoiliofemoral scan. Either a standard contrast media (SCM) protocol using 80 mL Iohexol 350 mgI/mL (iodine load: 28 gI) or a body-mass-index adjusted reduced contrast media (RCM) protocol using 40–70 mL Iohexol 350 mgI/mL (iodine load: 14–24.5 gI) were employed. Conventional images and virtual monoenergetic images at 40–80 keV were reconstructed. A threshold of 250 HU was set for sufficient attenuation along the arterial access pathway. A qualitative assessment used a five-point Likert scale. Sufficient attenuation in the thoracic aorta was observed for all patients in both groups using conventional images. In the abdominal, iliac, and femoral segments, sufficient attenuation was observed for the majority of patients when using virtual monoenergetic images (SCM: 96–100% of patients, RCM: 88–94%) without statistical difference between both groups. Segments with attenuation measurements below the threshold remained qualitatively assessable as well. Likert scores were ‘excellent’ for virtual monoenergetic images 50 keV and 55 keV in both groups (RCM: 1.2–1.4, SCM: 1.2–1.3). With diagnostic image quality maintained, it can be concluded that reduced iodine loads of 14–24.5 gI are feasible for pre-TAVI vascular assessment on a spectral detector CT scanner.

27 January 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
CMClaudius Melzig
Claudius Melzig
SHSibylle Hartmann
Sibylle Hartmann
ASAndrea Steuwe
Andrea Steuwe
JEJan Egger
Jan Egger
TDThuy D Do
Thuy D Do
MFMatthias Alexander Fink
Matthias Alexander Fink
Purpose: To assess the diagnostic accuracy of BMI-adapted, low-radiation and low-iodine dose, dual-source aortic CT for endoleak detection in non-obese and obese patients following endovascular aortic repair. Methods: In this prospective single-center study, patients referred for follow-up CT after endovascular repair with a history of at least one standard triphasic (native, arterial and delayed phase) routine CT protocol were enrolled. Patients were divided into two groups and allocated to a BMI-adapted (group A, BMI < 30 kg/m2; group B, BMI ≥ 30 kg/m2) double low-dose CT (DLCT) protocol comprising single-energy arterial and dual-energy delayed phase series with virtual non-contrast (VNC) reconstructions. An in-patient comparison of the DLCT and routine CT protocol as reference standard was performed regarding differences in diagnostic accuracy, radiation dose, and image quality. Results: Seventy-five patients were included in the study (mean age 73 ± 8 years, 63 (84%) male). Endoleaks were diagnosed in 20 (26.7%) patients, 11 of 53 (20.8%) in group A and 9 of 22 (40.9%) in group B. Two radiologists achieved an overall diagnostic accuracy of 98.7% and 97.3% for endoleak detection, with 100% in group A and 95.5% and 90.9% in group B. All examinations were diagnostic. The DLCT protocol reduced the effective dose from 10.0 ± 3.6 mSv to 6.1 ± 1.5 mSv (p < 0.001) and the total iodine dose from 31.5 g to 14.5 g in group A and to 17.4 g in group B. Conclusion: Optimized double low-dose dual-source aortic CT with VNC, arterial and delayed phase images demonstrated high diagnostic accuracy for endoleak detection and significant radiation and iodine dose reductions in both obese and non-obese patients compared to the reference standard of triple phase, standard radiation and iodine dose aortic CT.

6 September 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
CMClaudius Melzig
Claudius Melzig
VMVictoria Mayer
Victoria Mayer
MMMartin Moll
Martin Moll
ONOmar Naas
Omar Naas
SHSibylle Hartmann
Sibylle Hartmann
Fabian RengierFabian Rengier
Fabian Rengier
We assessed the effects of structured reporting (SR) of lower extremity CT angiography (CTA) on report quality and workflow efficiency compared with conventional reports (CR). Surveys were conducted at an academic radiology department before and after the introduction of an SR template. Participants (n = 39, 21) rated report quality and report creation effort (1: very dissatisfied/low to 10: very satisfied/high) and whether SR represents an improvement over CR (1: completely disagree to 5: completely agree). Four residents and two supervising radiologists created both CR and SR of 40 CTA examinations. Report creation time was measured and the factual accuracy of residents’ reports was judged. Report completeness (median 8.0 vs. 7.0, p = 0.016) and clinical usefulness (7.0 vs. 4.0, p = 0.029) were rated higher for SR. Supervising radiologists found report clarity improved by SR (8.0 vs. 4.5, p = 0.029). Report creation effort was unchanged (7.0 vs. 6.0, p > 0.05). SR was considered an improvement over CR (median 4.0, IQR,3.0–5.0). Report supervision was shortened by SR (6.2 ± 2.0 min vs. 10.6 ± 3.5 min, p < 0.001) but total time for report creation remained unchanged (36.6 ± 12.8 min vs. 36.4 ± 11.0 min, p > 0.05). Factual accuracy of residents’ SR was deemed higher (8.0/9.5 vs. 7.0/7.0, p = 0.006/ < 0.001). In conclusion, SR has the potential to improve report quality and workflow efficiency for lower extremity CTA.