Oliver Millán-Blasco

Dr. Oliver Millán-Blasco

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2017 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Oliver Millán-BlascoOliver Millán-Blasco
Oliver Millán-Blasco
JSJordi Salazar
Jordi Salazar
JCJUAN CHAVEZ
JUAN CHAVEZ
ATAntoni Turo-Peroy
Antoni Turo-Peroy
MGMiguel J. Garcia-Hernandez
Miguel J. Garcia-Hernandez
The objective of this paper is to measure the zero-flow offset variation in ultrasonic Clamp-on flowmeters produced by using pipes made of materials with a nonhomogeneous and nonlinear behavior. The evaluation of this phenomenon has been tested by the experimental measurement, the experiments consist of measuring the variation in the flow measurement when in “no-flow condition,” the transducers are moved along the pipe. Experimental results reveal that the reciprocity criterion is not fulfilled when nonhomogeneous and nonlinear pipe materials are used. Consequently, in these types of pipes materials, it is necessary to calibrate the offset when transducers are installed, and probably will need recalibration if the transducers are displaced to another position on the pipe. However, in installations, where it is not possible to stop flow in order to calibrate, the flowmeter will have an error in the measured value and this error will depend on the acoustic characteristics of the pipe material.

1 May 2017
Verified
Conference Paper
Closed access
Oliver Millán-BlascoOliver Millán-Blasco
Oliver Millán-Blasco
JSJordi Salazar
Jordi Salazar
JCJuan A. Chavez
Juan A. Chavez
ATAntoni Turo
Antoni Turo
MGMiguel J. Garcia-Hernandez
Miguel J. Garcia-Hernandez
This article analyses and explains the implications that dispersive materials have over the linearity in flow measurement when a Clamp-on ultrasonic flowmeter is used. This is of capital importance because dispersive materials are commonly used in the manufacture of transducer wedges and pipes. The evaluation of this phenomenon has been tested by experimental measurement. The used setup consisted of a water flow calibration facility where a commercial Clamp-on ultrasonic flowmeter was installed on it and its flow measurement was compared with a reference flowmeter. Two experiments have been conducted. A first experiment was performed to evaluate only the effect produced by the fact that the transducer wedge is made of dispersive material. For this reason, an ultrasonic flowmeter was installed on a pipe made of non-dispersive material, in this case, an INOX pipe. Linearity error introduced by the wedge was below 1%. This error complies with the accuracy specification of the ultrasonic flowmeter given by the manufacturer (±1.5%). Finally, a second experiment consisted of installing the ultrasonic flowmeter on a dispersive pipe (PVC pipe) in order to measure the worst condition (both materials, wedge and pipe, were dispersive). Under this condition, the linearity error was increased until it reaches a value of 6.4%. Moreover, in case of a dispersive material pipe, the bigger the pipe thickness is, the bigger non-linearity error is reached.

1 May 2017
Verified
Conference Paper
Closed access
JCJuan A. Chavez
Juan A. Chavez
MGMiguel J. Garcia-Hernandez
Miguel J. Garcia-Hernandez
Oliver Millán-BlascoOliver Millán-Blasco
Oliver Millán-Blasco
ITIgnasi Tur
Ignasi Tur
ATAntoni Turo
Antoni Turo
JSJordi Salazar
Jordi Salazar
This paper presents a comparison between two algorithms for sinusoidal signal characterization applied to QCM impedance measurements. These algorithms are the zero crossing and peak detection method and the 7 parameters sine-fitting method. Simulation and experimental results from both methods are shown in order to determine which method provides the best performance in terms of accuracy. Obtaining a precise value of the QCM impedance depends directly on the precise measurement of the amplitude and phase of two sinusoidal voltages. It was found that the sine-fitting method achieves better results without an excessive associated computational burden. These results will be applied to the development of a new technique for biofilm characterization based on multiple QCM impedance measurements.

17 April 2024 in Sensors
Verified
Journal Article
Open access
PDF file
NVNoelia Vaquero-Gallardo
Noelia Vaquero-Gallardo
Oliver Millán-BlascoOliver Millán-Blasco
Oliver Millán-Blasco
Herminio Martínez-GarcíaHerminio Martínez-García
Herminio Martínez-García
Active medical devices rely on a source of energy that is applied to the human body for specific purposes such as electrosurgery, ultrasounds for breaking up kidney stones (lithotripsy), laser irradiation, and other medical techniques and procedures that are extensively used. These systems must provide adequate working power with a commitment not to produce side effects on patients. Therefore, the materials used in these devices must effectively transmit energy, allow for security control, sense real-time variations in case of any issues, and ensure the implementation of closed-loop systems for control. This work extends to the experimental data adjustment of some different coating techniques based on plasma electro-oxidation (PEO) and thermal spray (TS) using fractional-order models. According to the physical structure of the coating in different coating techniques, Cole family models were selected. The experimental data were obtained by means of a vector network analyzer (VNA) in the frequency spectrum from 0.3 MHz to 5 MHz. The results show that some models from the Cole family (the single-dispersion model and inductive model) offered a goodness of fit to the experimental impedance in terms of RMSE error and a squared error R2 close to unity. The use of this type of fractional-order electrical model allows an adjustment with a very small number of elements compared to integer-order models, facilitating its use and a consequent reduction in instrumentation cost and the development of control devices that are more robust and easily miniaturized for embedded applications. Additionally, fractional-order models allow for more accurate assessment in industrial and medical applications.

1 September 2017
Verified
Conference Paper
Closed access
Oliver Millán-BlascoOliver Millán-Blasco
Oliver Millán-Blasco
JSJordi Salazar
Jordi Salazar
JCJUAN CHAVEZ
JUAN CHAVEZ
ATAntoni Turo
Antoni Turo
MGMiguel J. Garcia-Hernandez
Miguel J. Garcia-Hernandez
The following topics are dealt with: biomedical ultrasonics; medical image processing; ultrasonic imaging; biological tissues; ultrasonic transducers; biomechanics; blood vessels; biomedical transducers; diseases; and cancer.

22 July 2026 in Measurement
Verified
Journal Article
Open access
NVNoelia Vaquero-Gallardo
Noelia Vaquero-Gallardo
NSNicolau Solé-Coves
Nicolau Solé-Coves
Oliver Millán-BlascoOliver Millán-Blasco
Oliver Millán-Blasco
Herminio Martínez-GarcíaHerminio Martínez-García
Herminio Martínez-García