Noelia Vaquero-Gallardo

Ms. Noelia Vaquero-Gallardo

Universitat Politècnica de Catalunya, Barcelona, Catalonia, Spain
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
NVNoelia Vaquero-Gallardo
Noelia Vaquero-Gallardo
Herminio Martínez-GarcíaHerminio Martínez-García
Herminio Martínez-García
Electrical impedance tomography (EIT) is based on the physical principle of bioimpedance defined as the opposition that biological tissues exhibit to the flow of a rotating alternating electrical current. Consequently, here, we propose studying the characterization and classification of bioimpedance patterns based on EIT by measuring, on the forearm with eight electrodes in a non-invasive way, the potential drops resulting from the execution of six hand gestures. The starting point was the acquisition of bioimpedance patterns studied by means of principal component analysis (PCA), validated through the cross-validation technique, and classified using the k-nearest neighbor (kNN) classification algorithm. As a result, it is concluded that reduction and classification is feasible, with a sensitivity of 0.89 in the worst case, for each of the reduced bioimpedance patterns, leading to the following direct advantage: a reduction in the numbers of electrodes and electronics required. In this work, bioimpedance patterns were investigated for monitoring subjects’ mobility, where, generally, these solutions are based on a sensor system with moving parts that suffer from significant problems of wear, lack of adaptability to the patient, and lack of resolution. Whereas, the proposal implemented in this prototype, based on the so-called electrical impedance tomography, does not have these problems.

17 April 2024 in Sensors
Verified
Journal Article
Open access
PDF file
NVNoelia Vaquero-Gallardo
Noelia Vaquero-Gallardo
Oliver Millán-BlascoOliver Millán-Blasco
Oliver Millán-Blasco
Herminio Martínez-GarcíaHerminio Martínez-García
Herminio Martínez-García
Active medical devices rely on a source of energy that is applied to the human body for specific purposes such as electrosurgery, ultrasounds for breaking up kidney stones (lithotripsy), laser irradiation, and other medical techniques and procedures that are extensively used. These systems must provide adequate working power with a commitment not to produce side effects on patients. Therefore, the materials used in these devices must effectively transmit energy, allow for security control, sense real-time variations in case of any issues, and ensure the implementation of closed-loop systems for control. This work extends to the experimental data adjustment of some different coating techniques based on plasma electro-oxidation (PEO) and thermal spray (TS) using fractional-order models. According to the physical structure of the coating in different coating techniques, Cole family models were selected. The experimental data were obtained by means of a vector network analyzer (VNA) in the frequency spectrum from 0.3 MHz to 5 MHz. The results show that some models from the Cole family (the single-dispersion model and inductive model) offered a goodness of fit to the experimental impedance in terms of RMSE error and a squared error R2 close to unity. The use of this type of fractional-order electrical model allows an adjustment with a very small number of elements compared to integer-order models, facilitating its use and a consequent reduction in instrumentation cost and the development of control devices that are more robust and easily miniaturized for embedded applications. Additionally, fractional-order models allow for more accurate assessment in industrial and medical applications.

15 January 2026 in Sensors
Verified
Journal Article
Open access
PDF file
NVNoelia Vaquero-Gallardo
Noelia Vaquero-Gallardo
Herminio Martínez-GarcíaHerminio Martínez-García
Herminio Martínez-García
Oliver Millán-BlascoOliver Millán-Blasco
Oliver Millán-Blasco
Cryotherapy and radiofrequency (RF) treatments modulate tissue temperature to induce therapeutic effects; however, improper application can result in thermal injury. Traditional temperature-based monitoring methods rely on multiple thermal sensors whose accuracy strongly depends on their number and spatial positioning, often failing to detect early tissue crystallization. This study introduces a fractional order bioimpedance modelling framework for the early detection of tissue freezing during cryogenic and thermal medical treatments, with the feasibility and effectiveness of this approach having been reported in our prior publications. While bioimpedance spectroscopy itself is a well-est. The corresponablished technique in biomedical engineering, its novel application to predict and identify premature freezing events provides a new pathway for safe and efficient energy-based therapies. Fractional-order models derived from the Cole family accurately reproduce the complex electrical behavior of biological tissues using fewer parameters than classical integer-order models, thus reducing both hardware requirements and computational cost. Experimental impedance data from human abdominal, gluteal, and femoral regions were modelled to extract fractional parameters that serve as sensitive indicators of phase-transition onset. The results demonstrate that the proposed approach enables real-time identification of freezing-induced electrical transitions, offering a physiologically grounded alternative to conventional temperature-based monitoring. Furthermore, the fractional order bioimpedance method exhibits high reproducibility and selectivity, and its analytical figures of merit, including the limits of detection and quantification, support its use for reliable real-time tissue monitoring and early injury detection. Overall, the proposed fractional order bioimpedance framework enhances both safety and control precision in cryogenic and thermal medical applications.

19 October 2026 in Journal of Imaging Informatics in Medicine
Verified
Journal Article
Open access
PDF file
ANAlex Navarro Navarro
Alex Navarro Navarro
MHMarc Arriaga Hidalgo
Marc Arriaga Hidalgo
CRCarlos Moreno Rubio
Carlos Moreno Rubio
MTMaxime Talarmain
Maxime Talarmain
NVNoelia Vaquero-Gallardo
Noelia Vaquero-Gallardo
Current light-based devices, such as laser hair removal, intense pulsed light (IPL), vascular laser therapy, and dermatologic phototherapy, are widely used in clinical dermatology but rely heavily on subjective manual parameterization or uncalibrated point-based colorimeters. To overcome these limitations, this work presents a unified system for hair segmentation and skin characterization in macroscopic dermatological images. Unlike most existing literature that relies on dermoscopic datasets captured under highly controlled conditions, our approach is specifically designed for macroscopic images that replicate real clinical laser treatments. The proposed pipeline integrates a custom-trained variant of the YOLOv9 deep learning architecture for instance segmentation and classical image processing within a single workflow to extract objective skin and hair parameters such as phototype, hair density, color, and thickness. A color calibration stage using spectrophotometric measurements ensures accurate feature estimation regardless of illumination conditions. Experimental results show competitive segmentation metrics (mAP@50 $$\approx $$ ≈ 0.80) on a custom dataset featuring short, shaved hairs, typical of pre-treatment scenarios. These findings demonstrate the feasibility of the proposed pipeline in providing the objective, foundational skin and hair features required for future automated laser parameterization, paving the way for its extension to broader light-based medical therapies.