Shen Chong

Dr. Shen Chong


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2014 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Closed access
PDF file
SCShen Chong
Shen Chong
ZTZhi-Hong Tang
Zhi-Hong Tang
JHJun-Zu Hu
Jun-Zu Hu
GZGuo-Yao Zou
Guo-Yao Zou
RXRong-Chi Xiao
Rong-Chi Xiao
DYDong-Xue Yan
Dong-Xue Yan

1 November 2014 in Orthopaedics & Traumatology: Surgery & Research
Verified
Journal Article
Closed access
SCShen Chong
Shen Chong
ZTZ.-H. Tang
Z.-H. Tang
JHJ.-Z. Hu
J.-Z. Hu
GZG.-Y. Zou
G.-Y. Zou
RXR.-C. Xiao
R.-C. Xiao
DYD.-X. Yan
D.-X. Yan

1 November 2014 in Orthopedics
Verified
Journal Article
Closed access
PDF file
SCShen Chong
Shen Chong
ZTZhi-Hong Tang
Zhi-Hong Tang
JHJun-Zu Hu
Jun-Zu Hu
GZGuo-Yao Zou
Guo-Yao Zou
RXRong-Chi Xiao
Rong-Chi Xiao
Rotator cuff tears have a high recurrence rate, even after arthroscopic rotator cuff repair. Although some biomechanical evidence suggests the superiority of the double-row vs the single-row technique, clinical findings regarding these methods have been controversial. The purpose of this study was to determine whether the double-row repair method results in a lower incidence of recurrent tearing compared with the single-row method. Electronic databases were systematically searched to identify reports of randomized, controlled trials (RCTs) comparing single-row with double-row rotator cuff repair. The primary outcome assessed was retear of the repaired cuff. Secondary outcome measures were the American Shoulder and Elbow Surgeons (ASES) shoulder score, the Constant shoulder score, and the University of California, Los Angeles (UCLA) score. Heterogeneity between the included studies was assessed. Six studies involving 428 patients were included in the review. Compared with single-row repair, double-row repair demonstrated a lower retear incidence (risk ratio [RR]=1.71 [95% confidence interval (CI), 1.18–2.49]; P =.005; I 2 =0%) and a reduced incidence of partial-thickness retears (RR=2.16 [95% CI, 1.26–3.71]; P =.005; I 2 =26%). Functional ASES, Constant, and UCLA scores showed no difference between single- and double-row cuff repairs. Use of the double-row technique decreased the incidence of retears, especially partial-thickness retears, compared with the single-row technique. The functional outcome was not significantly different between the 2 techniques. To improve the structural outcome of the repaired rotator cuff, surgeons should use the double-row technique. However, further long-term RCTs on this topic are needed.


1 March 2015 in Orthopedics
Verified
Journal Article
Closed access
PDF file
SCShen Chong
Shen Chong
ZTZhi-Hong Tang
Zhi-Hong Tang
JHJun-Zu Hu
Jun-Zu Hu
GZGuo-Yao Zou
Guo-Yao Zou
RXRong-Chi Xiao
Rong-Chi Xiao
DYDong-Xue Yan
Dong-Xue Yan
Feature Article Chong Shen, MD; Zhi-Hong Tang, MD; Jun-Zu Hu, MD; Guo-Yao Zou, MD; Rong-Chi Xiao, MD; Dong-Xue Yan, MD Patient-specific instrumentation (PSI) has been introduced as a tool to increase the accuracy of total knee arthroplasty (TKA) compared with conventional instrumentation (CLI). However, previous studies have shown inconsistent results. The authors conducted a meta-analysis to compare the performance of PSI to CLI in TKA. PubMed, EMBASE, and Cochrane Central Register of Controlled Trials electronic databases were systematically searched to identify eligible trials published between 2000 and March 2014. Two reviewers independently assessed methodological quality according to the Cochrane Handbook. Subgroup analyses were performed based on the different study designs (randomized, controlled trial [RCT] vs non-randomized, controlled trial [non-RCT]), preoperative magnetic resonance imaging vs computed tomography, and systems of PSI to explore the source of heterogeneity. Fourteen studies (7 RCTs and 7 non-RCTs) involving 1906 patients were included. There were no statistical differences with respect to the outliers of mechanical axis, coronal femoral component, sagittal femoral component, femoral component rotation, operative time, blood loss, and length of hospital stay between PSI and CLI groups. The number of outliers in coronal tibial components (odds ratio, 2.29; 95% confidence interval, 1.20 to 4.35; P=.01) and sagittal tibial components (odds ratio, 1.67; 95% confidence interval, 1.16 to 2.42; P<.01) was significantly lower in the CLI group than in the PSI group. Based on the numbers available, the use of PSI compared with CLI was not likely to improve the accuracy of component alignment and treatment effects of TKA. Further high-quality RCTs are warranted to confirm the authors’ results. [Orthopedics. 2015; 38(3):e178–e188.] The authors are from the Department of Orthopedics, Affiliated Hospital of Guilin Medical College, Guilin, Guangxi, China. The authors have no relevant financial relationships to disclose. Correspondence should be addressed to: Chong Shen, MD, Department of Orthopedics, Affiliated Hospital of Guilin Medical College, Guilin, Guangxi, China ( sc821@foxmail.com). Total knee arthroplasty (TKA) is generally considered the standard treatment for end-stage osteoarthritis of the knee when nonoperative treatments are no longer helpful. Accurate alignment may correlate with good clinical outcomes,1,2 whereas malalignment may result in early loosening, lower functional scores, abnormal stress, and a higher implant failure rate.3–5 In the major arthroplasty centers, the rate of implant malposition could reach 20% to 40% in patients who undergo TKA with conventional instrumentation (CLI).6–8 To limit implant malpositioning, smart tools such as computer-assisted surgery (CAS) and patient-specific instrumentation (PSI) have been developed. Although CAS has been reported to improve alignment and reduce variation,9 it prolongs operative time and increases cost with a risk of pin-related complications.10,11 One recent alternative has been the development of PSI, which uses anatomical data obtained primarily from preoperative computed tomography (CT) or magnetic resonance imaging (MRI) to create disposable cutting blocks to the patient’s individual anatomy. Patient-specific instrumentation has the potential to improve component accuracy, eliminate the alignment outliers, reduce variation in implant position, and save operative time for TKA instruments. Despite its theoretical advantage, the effectiveness of PSI remains controversial. A few clinical studies reported that PSI resulted in better component alignment accuracy than conventional TKA instrumentation,12–14 whereas others reported that PSI did not surpass the accuracy of the CLI technique.15–18 The inconsistent results may be due to small sample sizes, diverse ethnicities, and different instruments. Several reviews have reported that PSI may achieve a high degree of mechanical alignment compared with CLI.19,20 By using meta-analysis to synthesize the evidence and estimate the effect size, the current authors sought to evaluate the performance of PSI compared with CLI in patients undergoing TKA. The authors hypothesized that PSI may have better performance than CLI in TKA concerning (1) outliers, (2) operative time, (3) blood loss, and (4) length of hospital stay. The electronic databases PubMed, EMBASE, and the Cochrane Central Register of Controlled Trials were searched for articles published between 2000 to March 2014 using the following terms: patient-specific, patient-matched, custom cutting, custom fit, total knee arthroplasty, total knee replacement, TKA, and TKR. Reference lists of the relevant articles were manually searched for additional trials. Moreover, gray literature was searched using Google search engines and the registration centers of clinical trials ( www.chictr.org/cn; www.who.int/ictrp/en; www.clinicaltrials.gov; www.nrr.nhs.uk; www.actr.org.au; www.controlled-trials.com; www.trialscentral.org). No languages or publication statuses were restricted. The following inclusion criteria were used: (1) randomized, controlled trial (RCT) or non-RCT; (2) performed in vivo; (3) adult patients underwent primary TKA; (4) compared PSI with CLI; (5) reported the outliers of at least 1 of the following outcomes: mechanical axis, coronal femoral component (CFC), coronal tibial component (CTC), sagittal femoral component (SFC), sagittal tibial component (STC), and femoral component rotation (FCR); and (6) included at least 40 patients. If multiple studies with overlapping data were identified, the authors included only the published report with the largest sample size. All studies that did not meet these criteria were excluded. Two reviewers (C.S., Z.-H.T.) independently extracted data using a standardized extraction form. Disagreements were resolved by...

20 November 2018 in Journal of Biological Engineering
Verified
Journal Article
Open access
PDF file
SCShen Chong
Shen Chong
TJTongmeng Jiang
Tongmeng Jiang
BZBo Zhu
Bo Zhu
YLYiguan Le
Yiguan Le
JLJianwei Liu
Jianwei Liu
XZXingdong Zhang
Xingdong Zhang
In vitro expansion of mesenchymal stem cells (MSCs) has been implicated in loss of multipotency, leading to impaired chondrogenic potential and an eventual therapeutic effect, as reported in our previous study. However, the precise regulatory mechanism is still unclear. Here, we demonstrate that endoplasmic reticulum (ER) stress and the unfolded protein response (UPR) were involved in transformation of MSCs induced by in vitro culture based on the comparative profiling of in vitro cultured bone marrow MSCs at passage 3 (P3 BMSCs) vs. fresh P0 BMSCs by microarray analysis. Indeed, RT-PCR and Western blot analysis showed significantly lower expression levels of three key UPR-related molecules, ATF4, ATF6 and XBP1, in P3 BMSCs than P0 BMSCs. Further, we found that UPR suppression by 4-phenylbutyrate (4-PBA) reduced the chondrogenic potential of P0 BMSCs and further cartilage regeneration. Conversely, UPR induction by tunicamycin (TM) enhanced the chondrogenic differentiation of P3 BMSCs and the therapeutic effect on cartilage repair. Thus, the decline in the chondrogenic potential of stem cells after in vitro culture and expansion may be due to changes in ER stress and the UPR pathway.