Andrew J Furlong

Mr. Andrew J Furlong

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2024 in Journal of Loss Prevention in the Process Industries
Verified
Journal Article
Open access
AFAndrew J Furlong
Andrew J Furlong
NBNicole K. Bond
Nicole K. Bond
MPMichael J. Pegg
Michael J. Pegg
RHRobin W. Hughes
Robin W. Hughes
The explosibility of metals typically used as oxygen carriers in chemical looping processes are reviewed. Chemical looping processes use intensified process conditions such as elevated temperatures and pressures to accelerate reduction and oxidation reactions of metals. A review of literature on metals indicates they are generally non-explosible under standard test conditions, however, at conditions used in chemical looping processes the opportunity to remove kinetic limitations exists resulting in reclassification of these dusts as marginally explosible under these circumstances. Potential locations and scenarios for explosions involving oxygen carriers in chemical looping processes are described. Operating conditions (temperature, pressure) and oxygen carrier qualities (base metal, support/loading) are reviewed for their effect on explosion severity parameters. These studies show explosions are unlikely to be severe in chemical looping reactors, but severity can increase while likelihood decreases in windboxes and in downstream process units following cooling. The potential for explosions where a metal oxide dust acts as the oxidizing agent for gaseous fuels through heterogeneous (chemical looping combustion – CLC) and homogenous (chemical looping oxygen uncoupling – CLOU) pathways as may be found in chemical looping processes is introduced, which we term a metal oxide reducing environment (MORE) explosion. Methane was shown to have the potential for the most serious consequences when reacting with copper- and manganese-oxides due to their reduction both being exothermic and increasing the quantity of gas present. Hematite and nickel oxide do not demonstrate this behaviour with common gaseous fuels. Potential prevention and mitigation strategies for explosions in chemical looping processes are briefly introduced. Particulate management strategies, venting, and downstream concerns are discussed.

6 April 2023 in Education for Chemical Engineers
Verified
Journal Article
Closed access
AFAndrew J Furlong
Andrew J Furlong
MPMichael J. Pegg
Michael J. Pegg

15 February 2024 in Applied Thermal Engineering
Verified
Journal Article
Closed access
AFAndrew J Furlong
Andrew J Furlong
HGHongtian Ge
Hongtian Ge
RHRobin W. Hughes
Robin W. Hughes
AMArturo Macchi
Arturo Macchi
JHJan Haelssig
Jan Haelssig

18 August 2025 in Industrial & Engineering Chemistry Research
Verified
Journal Article
Open access
AFAndrew J Furlong
Andrew J Furlong
NBNicole K. Bond
Nicole K. Bond
SCScott Champagne
Scott Champagne
JHJan B. Haelssig
Jan B. Haelssig
RSRobert T. Symonds
Robert T. Symonds
MPMichael J. Pegg
Michael J. Pegg
The technology readiness of chemical looping is rapidly being advanced by transforming batch-mode bench-scale systems into continuously or semicontinuously operating pilot units, and these changes in operating modes and scales introduce new levels of risk. To ensure pilot plants operate in a safe and successful manner and to sustain public support and a positive perception, it is important that a rigorous process safety approach is implemented in both the design and the operations stages of facilities, especially with limited operating history at larger scales. Beyond the application of technically sound engineering of individual unit operations, additional considerations are required for safer operations. The application of the inherently safer design (ISD) principles of minimization, substitution, moderation, and simplification are discussed within the context of chemical looping facilities, and example-based guidance is provided. Particular attention is paid to the selection of oxygen carriers and materials of construction to reduce or eliminate hazards. Passive and active control strategies are briefly discussed for their potential to mitigate accidents in pilot facilities, principally in managing loss of containment through secondary containment, and protecting workers through flame arresting and shielding. Management of change is introduced in a chemical looping pilot plant context, focused on examining alternative configurations and materials, recommissioning plants, and managing documentation and training with high turnover in academic settings. Finally, the need for incident reporting and knowledge sharing related to safety and accidents in the chemical looping community are discussed and recommendations on how this can be implemented are made.

20 January 2023 in Combustion and Flame
Verified
Journal Article
Closed access
AFAndrew J Furlong
Andrew J Furlong
JHJan Haelssig
Jan Haelssig
MPMichael J. Pegg
Michael J. Pegg

19 March 2024 in Energies
Verified
Journal Article
Open access
PDF file
HGHongtian Ge
Hongtian Ge
AFAndrew J Furlong
Andrew J Furlong
SCScott Champagne
Scott Champagne
RHRobin W. Hughes
Robin W. Hughes
JHJan Haelssig
Jan Haelssig
AMArturo Macchi
Arturo Macchi
The concentration of residual O2 in oxy-fuel combustion flue gas needs to be reduced before CO2 transportation, utilization, or storage. An original application of the printed circuit heat exchanger (PCHE) for catalytic combustion with natural gas (catalytic deoxygenation) is described for reducing the residual O2 concentration. The PCHE design features multiple adiabatic packed beds with interstage cooling and fuel injection, allowing precise control over the reaction extent and temperature within each reaction stage through the manipulation of fuel and utility flow rates. This work describes the design of a PCHE for methane–oxygen catalytic combustion where the catalyst loading is minimized while reducing the O2 concentration from 3 vol% to 100 ppmv, considering a maximum adiabatic temperature rise of 50 °C per stage. Each PCHE design differs by the number of reaction stages and its individual bed lengths. As part of the design process, a one-dimensional transient reduced-order reactor model (1D ROM) was developed and compared to temperature and species concentration axial profiles from 3D CFD simulations. The final design consists of five reaction stages and four heat exchanger sections, providing a PCHE length of 1.09 m at a processing rate of 12.3 kg/s flue gas per m3 PCHE.