Gen Pei

Dr. Gen Pei

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2021 in Sustainable Cities and Society
Verified
Journal Article
Closed access
GPGen Pei
Gen Pei
MTMary Taylor
Mary Taylor
DRDonghyun Rim
Donghyun Rim


14 September 2023 in Journal of Building Engineering
Verified
Journal Article
Closed access
GPGen Pei
Gen Pei
JFJames D. Freihaut
James D. Freihaut
DRDonghyun Rim
Donghyun Rim

4 July 2024 in Environmental Science: Processes & Impacts
Verified
Journal Article
Closed access
PDF file
GPGen Pei
Gen Pei
PAParham Azimi
Parham Azimi
DRDonghyun Rim
Donghyun Rim
JAJoseph G. Allen
Joseph G. Allen
The utilization of portable air cleaners (PACs) is a recommended supplemental approach to help remove airborne pathogens and mitigate disease transmission in learning environments. To improve PAC effectiveness, science-based information is needed to optimize their implementation strategies such as the deployment location, height, and number of PACs. In this study, we developed a Computational Fluid Dynamics (CFD) model to assess how PACs perform in occupied classrooms equipped with displacement and mixing ventilation systems. The results show that PACs with a flow rate of 2.6 h−1 reduce the mean aerosol intake of all students by up to 66%. A key benefit of using PACs is to facilitate air mixing and movement in indoor environments with inadequate ventilation, thereby effectively reducing high aerosol concentrations near the infector. Furthermore, our results highlight the impact of PAC location on its performance. PACs achieve the best effectiveness when placed closed to the infector (within a distance <3 m). In the absence of knowing who is infected, deploying a PAC at the center of the room is recommended. Moreover, adjusting PAC flow discharge height to the breathing height of occupants (e.g., 0.9–1.2 m for seated people) can enhance their effectiveness in spaces with poor air mixing.

3 September 2025 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
SPSeongjun Park
Seongjun Park
GPGen Pei
Gen Pei
RMRichard Mistrick
Richard Mistrick
DRDonghyun Rim
Donghyun Rim

30 April 2026 in ACS ES&T Air
Verified
Journal Article
Closed access
GPGen Pei
Gen Pei
PAParham Azimi
Parham Azimi
ZKZahra Keshavarz
Zahra Keshavarz
JVJose Vallarino
Jose Vallarino
WKWilliam Kessler
William Kessler
JAJoseph G. Allen
Joseph G. Allen