Peter Lomax

Dr. Peter Lomax


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
ZSZain Shami
Zain Shami
TATughrul Arslan
Tughrul Arslan
PLPeter Lomax
Peter Lomax
Shape Memory Alloys (SMAs) have emerged as a promising actuation technology for wearable rehabilitation robots due to their unique properties, including the shape memory effect, high actuation stress, pseudoelasticity, and three-dimensional actuation. With a significantly higher Young’s modulus than biological tissues, SMAs enable efficient and responsive interaction with the human body, making them well suited for musculoskeletal rehabilitation applications. This paper provides a comprehensive review of SMA-based wearable devices for both upper- and lower-limb rehabilitation. It explores their configurations, actuation mechanisms, associated challenges, and optimization strategies to enhance performance. By discussing recent advancements, this review aims to inform researchers and engineers on the development of sustainable, effective, and patient-centric wearable rehabilitation robots.

18 February 2024 in Sensors
Verified
Journal Article
Open access
PDF file
UAUsman Anwar
Usman Anwar
TATughrul Arslan
Tughrul Arslan
PLPeter Lomax
Peter Lomax
Microstrip crescent antennas offer compactness, conformability, low profile, high sensitivity, multi-band operability, cost-effectiveness and ease of fabrication in contrast to bulky, rigid horn, helical and Vivaldi antennas. This work presents crescent sensors for monitoring brain pathology associated with stroke and atrophy. Single- and multi-element crescent sensors are designed and validated by software simulations. The fabricated sensors are integrated with glasses and experimentally evaluated using a realistic brain phantom. The performance of the sensors is compared in terms of peak gain, directivity, radiation performance, flexibility and detection capability. The crescent sensors can detect the pathologies through the monitoring of backscattered electromagnetic signals that are triggered by dielectric variations in the affected tissues. The proposed sensors can effectively detect stroke and brain atrophy targets with a volume of 25 mm3 and 56 mm3, respectively. The safety of the sensors is examined through the evaluation of Specific Absorption Rate (peak SAR < 1.25 W/Kg, 100 mW), temperature increase within brain tissues (max: 0.155 °C, min: 0.115 °C) and electric field analysis. The results suggest that the crescent sensors can provide a flexible, portable and non-invasive solution to monitor degenerative brain pathology.

1 April 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
JXJing Xu
Jing Xu
GWGraham Wood
Graham Wood
EMEnrico Mastropaolo
Enrico Mastropaolo
PLPeter Lomax
Peter Lomax
MNMichael Newton
Michael Newton
RCRebecca Cheung
Rebecca Cheung
A graphene/poly(methyl methacrylate) (PMMA) closed cavity resonator with a resonant frequency at around 160 kHz has been fabricated. A six-layer graphene structure with a 450 nm PMMA laminated layer has been dry-transferred onto the closed cavity with an air gap of 105 μm. The resonator has been actuated in an atmosphere and at room temperature by mechanical, electrostatic and electro-thermal methods. The (1,1) mode has been observed to dominate the resonance, which suggests that the graphene/PMMA membrane has been perfectly clamped and seals the closed cavity. The degree of linearity of the membrane’s displacement versus the actuation signal has been determined. The resonant frequency has been observed to be tuned to around 4% by applying an AC voltage through the membrane. The strain has been estimated to be around 0.08%. This research puts forward a graphene-based sensor design for acoustic sensing.

14 August 2024 in Micro
Verified
Journal Article
Open access
PDF file
SSShakila Shaheen
Shakila Shaheen
TATughrul Arslan
Tughrul Arslan
PLPeter Lomax
Peter Lomax
This study presents the design and simulation of an RF MEMS variable capacitor with a high tuning ratio and high linearity factor of capacitance–voltage response. An electrostatic torsion actuator with planar and non-planar structures is presented to obtain the high tuning ratio by avoiding the occurrence of pull-in point. In the proposed design, the capacitor plate is connected to the electrostatic actuators by using the s-shaped beam. The proposed design shows a 138% tuning ratio with the planar structure of the actuator and 167% tuning ratio by implementing the non-planar structure. A linearity factor of 99% is attained by adjusting the rates at which the capacitor plate rises as the actuation voltage increases and the rate at which the capacitance decreases as the plate rises. Parametric optimization of the design is performed by utilizing the finite element method (FEM) analysis and high-frequency structural simulator (HFSS) analysis to obtain an optimized high-tuning ratio RF MEMS varactor at low actuation voltage. S-parameters of the design are presented on HFSS, with a 50 ohm coplanar waveguide (CPW) serving as the transmission line. The proposed RF MEMS varactor can be utilized in tunable RF devices.