Peter Homolka

Prof. Dr. Peter Homolka

orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 December 2002 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
WBW. Birkfellner
W. Birkfellner
MFM. Figl
M. Figl
KHK. Huber
K. Huber
FWF. Watzinger
F. Watzinger
FWF. Wanschitz
F. Wanschitz
HBH. Bergmann
H. Bergmann
Computer-aided surgery (CAS), the intraoperative application of biomedical visualization techniques, appears to be one of the most promising fields of application for augmented reality (AR), the display of additional computer-generated graphics over a real-world scene. Typically a device such as a head-mounted display (HMD) is used for AR. However, considerable technical problems connected with AR have limited the intraoperative application of HMDs up to now. One of the difficulties in using HMDs is the requirement for a common optical focal plane for both the realworld scene and the computer-generated image, and acceptance of the HMD by the user in a surgical environment. In order to increase the clinical acceptance of AR, we have adapted the Varioscope (Life Optics, Vienna), a miniature, cost-effective head-mounted operating binocular, for AR. In this paper, we present the basic design of the modified HMD, and the method and results of an extensive laboratory study for photogrammetric calibration of the Varioscope's computer displays to a real-world scene. In a series of 16 calibrations with varying zoom factors and object distances, mean calibration error was found to be 1.24 /spl plusmn/ 0.38 pixels or 0.12 /spl plusmn/ 0.05 mm for a 640 /spl times/ 480 display. Maximum error accounted for 3.33 /spl plusmn/ 1.04 pixels or 0.33 /spl plusmn/ 0.12 mm. The location of a position measurement probe of an optical tracking system was transformed to the display with an error of less than 1 mm in the real world in 56% of all cases. For the remaining cases, error was below 2 mm. We conclude that the accuracy achieved in our experiments is sufficient for a wide range of CAS applications.

9 September 2003 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
ABAndreas Beer
Andreas Beer
AGAndré Gahleitner
André Gahleitner
AHAnders Holm
Anders Holm
MTManfred Tschabitscher
Manfred Tschabitscher
PHPeter Homolka
Peter Homolka

1 July 2002 in Radiology
Verified
Journal Article
Closed access
PHPeter Homolka
Peter Homolka
ABAndreas Beer
Andreas Beer
WBWolfgang Birkfellner
Wolfgang Birkfellner
RNRobert Nowotny
Robert Nowotny
AGAndré Gahleitner
André Gahleitner
HBHelmar Bergmann
Helmar Bergmann
To correlate torque forces during insertion of screw-type dental implants with bone mineral density (BMD) values determined preoperatively. Dental quantitative computed tomography (CT) was performed with simultaneous imaging of five postmortem mandibles and a calibration standard containing defined concentrations of calcium hydroxyapatite. CT numbers were converted to local BMD values by assuming a linear relationship (BMD = a x HU + b), where a and b are calibration coefficients. The a, b, P, and t values, correlation coefficients, and standard errors were calculated. Dental implants (n = 25) were set, and insertion torques were recorded. BMD was determined at the implantation site and correlated with torque forces recorded during implant insertion. Calibration coefficients derived for specimens were compared with those derived for actual patients. Calibration coefficients (at 120 kV) for the postmortem specimens were a = 0.760 +/- 0.03 (mean +/- SD) and b = 2.8 +/- 3.7 and for the patients were a = 0.804 +/- 0.06 and b = 5.2 +/- 4.2. Calibrated BMD values at the location of dental implants exhibit a significant correlation (R(2) = 0.83, P <.001) with insertion torques on the basis of a second-order model, which yields torque = (0.0055 x BMD + 0.73)(2) for the implants used and the surgical technique applied. Correlation exists between BMD measured with dental quantitative CT and the insertion torque of dental implants.

1 October 2009 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
MSMarkus Stock
Markus Stock
MPMarlies Pasler
Marlies Pasler
WBWolfgang Birkfellner
Wolfgang Birkfellner
PHPeter Homolka
Peter Homolka
RPRichard Poetter
Richard Poetter
Dietmar GeorgDietmar Georg
Dietmar Georg

1 February 2001 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
WBWolfgang Birkfellner
Wolfgang Birkfellner
PSPeter Solar
Peter Solar
AGAndré Gahleitner
André Gahleitner
KHKlaus Huber
Klaus Huber
FKFranz Kainberger
Franz Kainberger
HBHelmar Bergmann
Helmar Bergmann

29 November 2021 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
XMXiangjie Ma
Xiangjie Ma
MBMartin Buschmann
Martin Buschmann
EUEwald Unger
Ewald Unger
PHPeter Homolka
Peter Homolka
Additive manufacturing and 3D printing is particularly useful in the production of phantoms for medical imaging applications including determination and optimization of (diagnostic) image quality and dosimetry. Additive manufacturing allows the leap from simple slab and stylized to (pseudo)-anthropomorphic phantoms. This necessitates the use of materials with x-ray attenuation as close as possible to that of the tissues or organs mimicked. X-ray attenuation properties including their energy dependence were determined for 35 printing materials comprising photocured resins and thermoplastic polymers. Prior to measuring x-ray attenuation in CT from 70 to 140 kVp, printing parameters were thoroughly optimized to ensure maximum density avoiding too low attenuation due to microscopic or macroscopic voids. These optimized parameters are made available. CT scanning was performed in a water filled phantom to guarantee defined scan conditions and accurate HU value determination. The spectrum of HU values covered by polymers printed using fused deposition modeling reached from −258 to +1,063 at 120 kVp (−197 to +1,804 at 70 kVp, to −266 to +985 at 140 kVp, respectively). Photocured resins covered 43 to 175 HU at 120 kVp (16–156 at 70, and 57–178 at 140 kVp). At 120 kVp, ASA mimics water almost perfectly (+2 HU). HIPS (−40 HU) is found close to adipose tissue. In all photocurable resins, and 17 printing filaments HU values decreased with increasing beam hardness contrary to soft tissues except adipose tissue making it difficult to mimic water or average soft tissue in phantoms correctly over a range of energies with one single printing material. Filled filaments provided both, the HU range, and an appropriate energy dependence mimicking bone tissues. A filled material with almost constant HU values was identified potentially allowing mimicking soft tissues by reducing density using controlled under-filling. The measurements performed in this study can be used to design phantoms with a wide range of x-ray contrasts, and energy dependence of these contrasts by combining appropriate materials. Data provided on the energy dependence can also be used to correct contrast or contrast to noise ratios from phantom measurements to real tissue contrasts or CNRs.