Aims: Pulmonary vein isolation (PVI) using cryoballoon ablation (CBA) is mainly reserved for patients with drug-refractory or drug-intolerant symptomatic atrial fibrillation. We evaluated a large cohort of patients treated in a real-world setting and examined the safety and efficacy profile of CBA when applied as a first-line treatment for atrial fibrillation. Methods: In total, 249 patients (23% women; 56 ± 13 years; mean left atrial diameter 41 ± 7 mm; 73.5% paroxysmal atrial fibrillation; and 26.5% persistent atrial fibrillation) underwent an index PVI by CBA. Data were collected prospectively in the framework of the 1STOP ClinicalService project, involving 26 Italian cardiology centers. Results: Median procedure and fluoroscopy times were 90.0 and 21.0 min, respectively. Acute procedural success was 99.8%. Acute/periprocedural complications were observed in seven patients (2.8%), including: four transient diaphragmatic paralyses, one pericardial effusion (not requiring any intervention), one transient ischemic attack, and one minor vascular complication. The Kaplan--Meier freedom from atrial fibrillation recurrence was 86.3% at 12 months and 76% at 24 months. Seventeen patients (6.8%) had a repeat catheter ablation procedure during the follow-up period. At last follow-up, 10% of patients were on an anticoagulation therapy, whereas 6.8% were on an antiarrhythmic drug. Conclusion: In our multicenter real-world experience, PVI by CBA in a first-line atrial fibrillation patient population was well tolerated, effective, and promising. CBA with a PVI strategy can be used to treat patients with paroxysmal and persistent atrial fibrillation with good acute procedural success, short procedure times, and acceptable safety. Clinical Trial Registration: clinicaltrials.gov (NCT01007474).
(1) Background/Objective Balloon-guided catheter ablation (CA) has emerged as an alternative option for atrial fibrillation (AF) management. The recent introduction of a novel-size adjustable second-generation cryoballoon (CB) system offers innovations, but clinical outcomes remain unexplored. This study aims to assess the acute performance of the POLARx FIT™ CB system in AFCA. (2) Methods: Consecutive patients undergoing AF ablation with the POLARx FIT™ CB system in our center were included. The primary outcome was the rate of 31 mm balloon-size utilization, with secondary outcomes including acute pulmonary vein isolation (PVI) rate, periprocedural complications, and in-hospital AF recurrences. (3) Results: Twenty-four patients with a mean age of 59.5 years, predominantly male (87.5%), and exhibiting paroxysmal AF (91.7%) were enrolled. Procedural characteristics demonstrated a high acute success rate (100% PV isolation) with a favorable safety profile. Notably, the 31 mm CB configuration was utilized in 51% of applications, showcasing its adaptability in challenging anatomies. No major complications occurred, with two patients experiencing in-hospital self-limiting AF recurrences. (4) Conclusions: This study represents the first comprehensive assessment of the POLARx FIT™ CB system in AF ablation. While acknowledging the study’s limitations, this novel CB emerges as a promising tool, warranting further exploration in larger studies with extended follow-up periods.