Zhenrong Zhang

Prof. Zhenrong Zhang

School of computer, electronics and information,Guangxi Unversity,Nanning 530004,P.R.China
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 August 2019 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
LYLinfeng Yang
Linfeng Yang
JLJiangyao Luo
Jiangyao Luo
Yan XuYan Xu
Yan Xu
Zhenrong ZhangZhenrong Zhang
Zhenrong Zhang
Zhaoyang DongZhaoyang Dong
Zhaoyang Dong

25 June 2023 in Electronics
Verified
Journal Article
Open access
PDF file
HZHongyu Zhou
Hongyu Zhou
DWDongying Wang
Dongying Wang
Yang YuYang Yu
Yang Yu
Zhenrong ZhangZhenrong Zhang
Zhenrong Zhang
Gesture recognition, as a core technology of human–computer interaction, has broad application prospects and brings new technical possibilities for smart homes, medical care, sports training, and other fields. Compared with the traditional human–computer interaction models based on PC use with keyboards and mice, gesture recognition-based human–computer interaction modes can transmit information more naturally, flexibly, and intuitively, which has become a research hotspot in the field of human–computer interaction in recent years. This paper described the current status of gesture recognition technology, summarized the principles and development history of electromagnetic wave sensor recognition, stress sensor recognition, electromyographic sensor recognition, and visual sensor recognition, and summarized the improvement of this technology by researchers in recent years through the direction of sensor structure, selection of characteristic signals, the algorithm of signal processing, etc. By sorting out and comparing the typical cases of the four implementations, the advantages and disadvantages of each implementation and the application scenarios were discussed from the two aspects of dataset size and accuracy. Based on the abovementioned discussion, the problems and challenges of current gesture recognition technology were discussed in terms of the biocompatibility of sensor structures, wearability and adaptability, stability, robustness, and crossover of signal acquisition and analysis algorithms, and the future development directions in this field were proposed.

22 September 2022 in Entropy
Verified
Journal Article
Open access
PDF file
QLQiang Liu
Qiang Liu
YHYinming Huang
Yinming Huang
DYDu Yongqiang
Du Yongqiang
ZGZhao zhen geng
Zhao zhen geng
MGMinming Geng
Minming Geng
KWKejin Wei
Kejin Wei
Quantum key distribution (QKD), guaranteed by the principles of quantum mechanics, is one of the most promising solutions for the future of secure communication. Integrated quantum photonics provides a stable, compact, and robust platform for the implementation of complex photonic circuits amenable to mass manufacture, and also allows for the generation, detection, and processing of quantum states of light at a growing system’s scale, functionality, and complexity. Integrated quantum photonics provides a compelling technology for the integration of QKD systems. In this review, we summarize the advances in integrated QKD systems, including integrated photon sources, detectors, and encoding and decoding components for QKD implements. Complete demonstrations of various QKD schemes based on integrated photonic chips are also discussed.

11 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
HHhuimin Huang
huimin Huang
Zhenrong ZhangZhenrong Zhang
Zhenrong Zhang
Yang YuYang Yu
Yang Yu
LZLingjun Zhou
Lingjun Zhou
YTyuyu tao
yuyu tao
Junbo YangJunbo Yang
Junbo Yang
A novel magnetic field sensor comprising a photonic crystal fiber (PCF) is designed and investigated based on surface plasmon resonance (SPR). We use finite element analysis in order to analyze the sensing characteristics of the magnetic field sensor. The simulation results show that the sensor is very sensitive to the change of refractive index and has good linearity in the refractive index range from 1.43–1.45. The thickness of the metal film and the metal material has great influence on the resonance wavelength and the peak of the loss spectrum, the diameter of the central air hole will affect SPP excitation. When the thickness of gold layer is 50 nm, the refractive index sensitivity is 4125 nm/RIU in the refractive index range from 1.43–1.45. Using the designed sensor for magnetic field sensing, the loss spectrum is red-shifted with the increase of the magnetic field, the highest magnetic field sensitivity can reach 61.25 pm/Oe in the range from 50 Oe to 130 Oe. The sensor not only has high sensitivity of refractive index, but it can also realize accurate measurement of magnetic field. It has huge application potential in complex environment, remote sensing, real-time monitoring, and other fields.

28 April 2022 in Optics Express
Verified
Journal Article
Closed access
SYSiyu Yao
Siyu Yao
Yang YuYang Yu
Yang Yu
SQShangpeng Qin
Shangpeng Qin
DWDongying Wang
Dongying Wang
PYPeiguang Yan
Peiguang Yan
Zhenrong ZhangZhenrong Zhang
Zhenrong Zhang
A photonic crystal fiber utilizing surface plasmon resonance (PCF-SPR) sensor based on refractive index (RI) control of magnetic fluid (MF) is designed. The air holes of the sensor are arranged in a hexagonal shape, and the optical field transmission channels on both sides of the central air hole can effectively confine the energy of the optical field. We use MF as the sensing medium, and coat the inner wall of the central air hole with gold. It can effectively stimulate the SPR effect to achieve the purpose of magneto-refractive modulation. We study the sensing characteristics of the proposed sensor by finite element analysis. The results show that the highest refractive index sensitivity reaches 19520 nm/RIU in the RI range of 1.42-1.435 and the maximum figure of merit (FOM) is 374.3 RIU-1. In addition, the magnetic field and the temperature response characteristics of the designed sensor are also investigated. In the magnetic field range of 50-130 Oe, the magnetic field sensitivity is 590 pm/Oe. In the temperature range of 24.3-144.3 °C, the temperature sensitivity is only -29.7 pm/℃. The proposed sensor has significant advantages such as stable structure, high sensitivity, easy integration, resistance to electromagnetic interference and can be used for weak magnetic magnitude detection. It has wide application prospects in industrial production, military, and medical equipment.

9 March 2022 in Optics Express
Verified
Journal Article
Closed access
JLJunyang Lu
Junyang Lu
Yang YuYang Yu
Yang Yu
SQShangpeng Qin
Shangpeng Qin
MLMinwei Li
Minwei Li
QBQiang Bian
Qiang Bian
Zhenrong ZhangZhenrong Zhang
Zhenrong Zhang
Based on the polymer encapsulation method, a compact structure and high-sensitivity temperature and pressure dual parametric sensor was developed in this paper by wrapping an optical microfiber coupler (OMC) in polydimethylsiloxane (PDMS). Benefiting from the stable chemical properties and good optical field control ability of PDMS, the sensor showed good stability and repeatability. The dependence of the sensor sensitivity on wavelength, temperature, and pressure was experimentally investigated. The results showed that the temperature and pressure sensitivity could reach −2.283 nm/°C and 3.301 nm/Mpa in the C-band range. To overcome the cross-sensitivity of sensor temperature and pressure, a sensitivity matrix was established to realize dual-parameter simultaneous demodulation. In addition, the pressure repeatability of the sensor was tested. Based on this, the sensitivity matrix was further calibrated to reduce the error and improve the accuracy of demodulation. Finally, we also designed a protective shell for the sensor to meet the requirements of practical marine applications. Compared with other existing types of optical fiber sensors, this sensor has the advantages of simple fabrication, high sensitivity, and environmental adaptability, and has great potential for application in the field of marine environmental monitoring.