18 February 2015 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
RLRoberto M. Lang
Roberto M. Lang
LBLuigi P. Badano
Luigi P. Badano
VMVictor Mor-Avi
Victor Mor-Avi
JAJonathan Afilalo
Jonathan Afilalo
AAAnderson Armstrong
Anderson Armstrong
JVJens-Uwe Voigt
Jens-Uwe Voigt
The rapid technological developments of the past decade and the changes in echocardiographic practice brought about by these developments have resulted in the need for updated recommendations to the previously published guidelines for cardiac chamber quantification, which was the goal of the joint writing group assembled by the American Society of Echocardiography and the European Association of Cardiovascular Imaging. This document provides updated normal values for all four cardiac chambers, including three-dimensional echocardiography and myocardial deformation, when possible, on the basis of considerably larger numbers of normal subjects, compiled from multiple databases. In addition, this document attempts to eliminate several minor discrepancies that existed between previously published guidelines.

1 March 2011 in Journal of the American Society of Echocardiography
Verified
Journal Article
Closed access
VMVictor Mor-Avi
Victor Mor-Avi
RLRoberto M. Lang
Roberto M. Lang
LBLuigi P. Badano
Luigi P. Badano
MBMarek Belohlavek
Marek Belohlavek
NCNuno Miguel Cardim
Nuno Miguel Cardim
JZJosé Luis Zamorano
José Luis Zamorano

1 March 2011 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
VMVictor Mor-Avi
Victor Mor-Avi
RLRoberto M. Lang
Roberto M. Lang
LBLuigi P. Badano
Luigi P. Badano
MBMarek Belohlavek
Marek Belohlavek
NCNuno Miguel Cardim
Nuno Miguel Cardim
JZJose Luis Zamorano
Jose Luis Zamorano
Echocardiographic imaging is ideally suited for the evaluation of cardiac mechanics because of its intrinsically dynamic nature. Because for decades, echocardiography has been the only imaging modality that allows dynamic imaging of the heart, it is only natural that new, increasingly automated techniques for sophisticated analysis of cardiac mechanics have been driven by researchers and manufacturers of ultrasound imaging equipment. Several such techniques have emerged over the past decades to address the issue of reader's experience and inter-measurement variability in interpretation. Some were widely embraced by echocardiographers around the world and became part of the clinical routine, whereas others remained limited to research and exploration of new clinical applications. Two such techniques have dominated the research arena of echocardiography: (1) Doppler-based tissue velocity measurements, frequently referred to as tissue Doppler or myocardial Doppler, and (2) speckle tracking on the basis of displacement measurements. Both types of measurements lend themselves to the derivation of multiple parameters of myocardial function. The goal of this document is to focus on the currently available techniques that allow quantitative assessment of myocardial function via image-based analysis of local myocardial dynamics, including Doppler tissue imaging and speckle-tracking echocardiography, as well as integrated back- scatter analysis. This document describes the current and potential clinical applications of these techniques and their strengths and weaknesses, briefly surveys a selection of the relevant published literature while highlighting normal and abnormal findings in the context of different cardiovascular pathologies, and summarizes the unresolved issues, future research priorities, and recommended indications for clinical use.

15 August 2006 in Circulation
Verified
Journal Article
Closed access
LSLissa Sugeng
Lissa Sugeng
VMVictor Mor-Avi
Victor Mor-Avi
LWLynn Weinert
Lynn Weinert
JNJohannes Niel
Johannes Niel
CEChristian Ebner
Christian Ebner
HNHans-Joachim Nesser
Hans-Joachim Nesser
Background— Cardiac CT (CCT) and real-time 3D echocardiography (RT3DE) are being used increasingly in clinical cardiology. CCT offers superb spatial and contrast resolution, resulting in excellent endocardial definition. RT3DE has the advantages of low cost, portability, and live 3D imaging without offline reconstruction. We sought to compare both CCT and RT3DE measurements of left ventricular size and function with the standard reference technique, cardiac MR (CMR). Methods and Results— In 31 patients, RT3DE data sets (Philips 7500) and long-axis CMR (Siemens, 1.5 T) and CCT (Toshiba, 16-slice MDCT) images were obtained on the same day without β-blockers. All images were analyzed to obtain end-systolic and end-diastolic volumes and ejection fractions using the same rotational analysis to eliminate possible analysis-related differences. Intertechnique agreement was tested through linear regression and Bland-Altman analyses. Repeated measurements were performed to determine intraobserver and interobserver variability. Both CCT and RT3DE measurements resulted in high correlation ( r 2 >0.85) compared with CMR. However, CCT significantly overestimated end-diastolic and end-systolic volumes (26 and 19 mL; P <0.05), resulting in a small but significant bias in ejection fraction (−2.8%). RT3DE underestimated end-diastolic and end-systolic volumes only slightly (5 and 6 mL), with no significant bias in EF (0.3%; P =0.68). The limits of agreement with CMR were comparable for the 2 techniques. The variability in the CCT measurements was roughly half of that in either RT3DE or CMR values. Conclusions— CCT provides highly reproducible measurements of left ventricular volumes, which are significantly larger than CMR values. RT3DE measurements compared more favorably with the CMR reference, albeit with higher variability.

1 July 2008 in JACC: Cardiovascular Imaging
Verified
Journal Article
Closed access
VMVictor Mor-Avi
Victor Mor-Avi
CJCarly Jenkins
Carly Jenkins
HKHarald P. Kühl
Harald P. Kühl
HNHans-Joachim Nesser
Hans-Joachim Nesser
TMThomas Marwick
Thomas Marwick
RLRoberto M. Lang
Roberto M. Lang

30 November 2005 in European Heart Journal
Verified
Journal Article
Open access
PDF file
LJLawrence D. Jacobs
Lawrence D. Jacobs
ISIvan S. Salgo
Ivan S. Salgo
SGSascha Goonewardena
Sascha Goonewardena
LWLynn Weinert
Lynn Weinert
PCPatrick Coon
Patrick Coon
RLRoberto M. Lang
Roberto M. Lang
Aims Determination of left ventricular (LV) volumes and ejection fraction (EF) from two-dimensional echocardiographic (2DE) images is subjective, time-consuming, and relatively inaccurate because of foreshortened views and the use of geometric assumptions. Our aims were (1) to validate a new method for rapid, online measurement of LV volumes from real-time three-dimensional echocardiographic (RT3DE) data using cardiac magnetic resonance (CMR) as the reference and (2) to compare its accuracy and reproducibility with standard 2DE measurements. Methods and results CMR, 2DE, and RT3DE datasets were obtained in 50 patients. End-systolic and end-diastolic volumes (ESV and EDV) were calculated from the 2DE images using biplane method of disks. ES and ED RT3DE datasets were analysed using prototype software designed to automatically detect the endocardial surface using a deformable shell model and calculate ESV and EDV from voxel counts. 2DE and RT3DE-derived volumes were compared with CMR (linear regression, Bland–Altman analysis). In most patients, analysis of RT3DE data required <2 min per patient. RT3DE measurements correlated highly with CMR (r: 0.96, 0.97, and 0.93 for EDV, ESV, and EF, respectively) with small biases (−14 mL, −6.5 mL, −1%) and narrow limits of agreement (SD: 17 mL, 16 mL, 6.4%). 2DE measurements correlated less well with CMR (r: 0.89, 0.92, 0.86) with greater biases (−23 mL, −15 mL, 1%) and wider limits of agreement (SD: 29 mL, 24 mL, 9.5%). RT3DE resulted in lower intra-observer (EDV: 7.9 vs. 23%; ESV: 7.6 vs. 26%) and inter-observer variability (EDV: 11 vs. 26%; ESV: 13 vs. 31%). Conclusion Semi-automated detection of the LV endocardial surface from RT3DE data is suitable for clinical use because it allows rapid, accurate, and reproducible measurements of LV volumes, superior to conventional 2DE methods.