Wendy Hartogensis

Dr. Wendy Hartogensis

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 February 2022 in Vaccines
Verified
Journal Article
Open access
PDF file
AMAshley Mason
Ashley Mason
PKPatrick Kasl
Patrick Kasl
WHWendy Hartogensis
Wendy Hartogensis
JNJoseph L. Natale
Joseph L. Natale
SDStephan Dilchert
Stephan Dilchert
FHFrederick M. Hecht
Frederick M. Hecht
There is significant variability in neutralizing antibody responses (which correlate with immune protection) after COVID-19 vaccination, but only limited information is available about predictors of these responses. We investigated whether device-generated summaries of physiological metrics collected by a wearable device correlated with post-vaccination levels of antibodies to the SARS-CoV-2 receptor-binding domain (RBD), the target of neutralizing antibodies generated by existing COVID-19 vaccines. One thousand, one hundred and seventy-nine participants wore an off-the-shelf wearable device (Oura Ring), reported dates of COVID-19 vaccinations, and completed testing for antibodies to the SARS-CoV-2 RBD during the U.S. COVID-19 vaccination rollout. We found that on the night immediately following the second mRNA injection (Moderna-NIAID and Pfizer-BioNTech) increases in dermal temperature deviation and resting heart rate, and decreases in heart rate variability (a measure of sympathetic nervous system activation) and deep sleep were each statistically significantly correlated with greater RBD antibody responses. These associations were stronger in models using metrics adjusted for the pre-vaccination baseline period. Greater temperature deviation emerged as the strongest independent predictor of greater RBD antibody responses in multivariable models. In contrast to data on certain other vaccines, we did not find clear associations between increased sleep surrounding vaccination and antibody responses.

20 June 2024 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
VVVarun K. Viswanath
Varun K. Viswanath
WHWendy Hartogensis
Wendy Hartogensis
SDStephan Dilchert
Stephan Dilchert
LPLeena Pandya
Leena Pandya
FHFrederick M. Hecht
Frederick M. Hecht
BSBenjamin L. Smarr
Benjamin L. Smarr
Sleep monitoring has become widespread with the rise of affordable wearable devices. However, converting sleep data into actionable change remains challenging as diverse factors can cause combinations of sleep parameters to differ both between people and within people over time. Researchers have attempted to combine sleep parameters to improve detecting similarities between nights of sleep. The cluster of similar combinations of sleep parameters from a night of sleep defines that night’s sleep phenotype. To date, quantitative models of sleep phenotype made from data collected from large populations have used cross-sectional data, which preclude longitudinal analyses that could better quantify differences within individuals over time. In analyses reported here, we used five million nights of wearable sleep data to test (a) whether an individual’s sleep phenotype changes over time and (b) whether these changes elucidate new information about acute periods of illness (e.g., flu, fever, COVID-19). We found evidence for 13 sleep phenotypes associated with sleep quality and that individuals transition between these phenotypes over time. Patterns of transitions significantly differ (i) between individuals (with vs. without a chronic health condition; chi-square test; p-value < 1e−100) and (ii) within individuals over time (before vs. during an acute condition; Chi-Square test; p-value < 1e−100). Finally, we found that the patterns of transitions carried more information about chronic and acute health conditions than did phenotype membership alone (longitudinal analyses yielded 2–10× as much information as cross-sectional analyses). These results support the use of temporal dynamics in the future development of longitudinal sleep analyses.

20 February 2019 in JMIR Research Protocols
Verified
Journal Article
Open access
AMAshley Mason
Ashley Mason
LSLaura Saslow
Laura Saslow
PMPatricia J Moran
Patricia J Moran
SKSarah Kim
Sarah Kim
PWPriyanka K Wali
Priyanka K Wali
FHFrederick Hecht
Frederick Hecht
Background: Diet patterns have a profound influence on glycemic control for individuals with type 2 diabetes mellitus (T2DM), and craving-related eating is an important obstacle to dietary adherence. A growing body of research suggests that carbohydrate-restricted (CR) diets can improve glycemic control and reduce medication dependence in T2DM. However, limited data speak to the effects of long-term adherence to CR diets. Mindful eating training has been shown to reduce craving-related eating in overweight populations but has yet to be examined as a behavioral support for dietary adherence in T2DM. This trial examines behavioral mechanisms, particularly craving-related eating, through which mindful eating training might improve adherence to CR dietary recommendations in T2DM. This will clarify the importance of focusing on craving-related eating in the optimization of dietary adherence interventions. Objective: The aim of this trial is to determine whether providing training in mindful eating increases adherence to a CR dietary recommendation in T2DM. Methods: We are randomizing 60 participants to receive a CR diet with or without mindful eating training (12-week group intervention) and are following participants for 12 weeks after intervention completion. We hypothesize that participants who receive mindful eating training (relative to those who do not) will demonstrate greater adherence to the CR diet. Results: Our primary outcome is change in craving-related eating, as assessed using an ecological momentary assessment mobile phone–based platform. Secondary behavioral pathway outcomes include changes in stress-related eating, impulsivity, glycemic control, weight change, dietary adherence, and resumption of dietary adherence after dietary nonadherence. Conclusions: This theory-driven trial will shed light on the impact of mindfulness training on mechanisms that may impact dietary adherence in T2DM. Clinical Trial: ClinicalTrials.gov NCT03207711; https://clinicaltrials.gov/ct2/show/NCT03207711 (Archived by WebCite at http://www.webcitation.org/73pXscwaU)

1 January 2020 in Global Advances in Health and Medicine
Verified
Journal Article
Open access
PDF file
RCRebecca S Crane
Rebecca S Crane
FHFrederick M Hecht
Frederick M Hecht
JBJudson Brewer
Judson Brewer
GGGemma M Griffith
Gemma M Griffith
WHWendy Hartogensis
Wendy Hartogensis
WKWillem Kuyken
Willem Kuyken
Background: The Mindfulness-Based Interventions: Teaching Assessment Criteria (MBI:TAC) is a widely used tool for assessing fidelity in mindfulness-based program (MBP) research and training. It also supports MBP teacher reflective and skill development. MBI:TAC assessors review MBP teaching and rate the teaching on 6 domains. The MBI:TAC yields individual domain and overall scores, using 6 levels of competence. Although the MBI:TAC is widely used in MBP research and training, research is at an early stage. Objective: We developed and tested a method of training MBI:TAC assessors to use the tool reliably and examined interrater reliability of the tool. Methods: A total of 31 international senior MBP teachers were recruited to join an online training to build their skills in using the MBI:TAC. The training systematically and iteratively built familiarity and skills in assessing the 6 MBI:TAC domains. Qualitative and quantitative data on trainee’s experience of the training were gathered. Interrater reliability in using the tool was tested each week of the training. At the end of the training, interrater reliability was tested by asking trainees to individually assess videos that they had not previously seen. Their ratings were compared to benchmark assessments, which had been established via consensus agreement between 4 expert users of the MBI:TAC. Results: The training was well received and appreciated, with some challenges experienced in applying the assessment methodology. Participants’ ratings became progressively more in line with one another and the benchmark ratings during the training. At the end, interrater reliability was high (ranging from 0.67 to 1.0). Conclusion: It is possible for senior MBP trainers, coming from different regions in the world, to align toward common understandings of the elements of MBP teaching competence and program integrity. An assessor training methodology was tested, and the learning from this project has led to refinements for future delivery.

12 March 2024 in Sensors
Verified
Journal Article
Open access
PDF file
PKPatrick Kasl
Patrick Kasl
LBLauryn Keeler Bruce
Lauryn Keeler Bruce
WHWendy Hartogensis
Wendy Hartogensis
Subhasis DasguptaSubhasis Dasgupta
Subhasis Dasgupta
LPLeena S. Pandya
Leena S. Pandya
BSBenjamin Smarr
Benjamin Smarr
Commercially available wearable devices (wearables) show promise for continuous physiological monitoring. Previous works have demonstrated that wearables can be used to detect the onset of acute infectious diseases, particularly those characterized by fever. We aimed to evaluate whether these devices could be used for the more general task of syndromic surveillance. We obtained wearable device data (Oura Ring) from 63,153 participants. We constructed a dataset using participants’ wearable device data and participants’ responses to daily online questionnaires. We included days from the participants if they (1) completed the questionnaire, (2) reported not experiencing fever and reported a self-collected body temperature below 38 °C (negative class), or reported experiencing fever and reported a self-collected body temperature at or above 38 °C (positive class), and (3) wore the wearable device the nights before and after that day. We used wearable device data (i.e., skin temperature, heart rate, and sleep) from the nights before and after participants’ fever day to train a tree-based classifier to detect self-reported fevers. We evaluated the performance of our model using a five-fold cross-validation scheme. Sixteen thousand, seven hundred, and ninety-four participants provided at least one valid ground truth day; there were a total of 724 fever days (positive class examples) from 463 participants and 342,430 non-fever days (negative class examples) from 16,687 participants. Our model exhibited an area under the receiver operating characteristic curve (AUROC) of 0.85 and an average precision (AP) of 0.25. At a sensitivity of 0.50, our calibrated model had a false positive rate of 0.8%. Our results suggest that it might be possible to leverage data from these devices at a public health level for live fever surveillance. Implementing these models could increase our ability to detect disease prevalence and spread in real-time during infectious disease outbreaks.

24 September 2021 in Mindfulness
Verified
Journal Article
Closed access
PDF file
SHSara J. Sagui Henson
Sara J. Sagui Henson
RRRachel M. Radin
Rachel M. Radin
KJKinnari Jhaveri
Kinnari Jhaveri
JBJudson A. Brewer
Judson A. Brewer
MCMichael Cohn
Michael Cohn
AMAshley Mason
Ashley Mason