Subhasis Dasgupta

Dr. Subhasis Dasgupta

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AMAshley Mason
Ashley Mason
FHFrederick M. Hecht
Frederick M. Hecht
SDShakti K. Davis
Shakti K. Davis
JNJoseph L. Natale
Joseph L. Natale
WHWendy Hartogensis
Wendy Hartogensis
BSBenjamin L. Smarr
Benjamin L. Smarr
Early detection of diseases such as COVID-19 could be a critical tool in reducing disease transmission by helping individuals recognize when they should self-isolate, seek testing, and obtain early medical intervention. Consumer wearable devices that continuously measure physiological metrics hold promise as tools for early illness detection. We gathered daily questionnaire data and physiological data using a consumer wearable (Oura Ring) from 63,153 participants, of whom 704 self-reported possible COVID-19 disease. We selected 73 of these 704 participants with reliable confirmation of COVID-19 by PCR testing and high-quality physiological data for algorithm training to identify onset of COVID-19 using machine learning classification. The algorithm identified COVID-19 an average of 2.75 days before participants sought diagnostic testing with a sensitivity of 82% and specificity of 63%. The receiving operating characteristic (ROC) area under the curve (AUC) was 0.819 (95% CI [0.809, 0.830]). Including continuous temperature yielded an AUC 4.9% higher than without this feature. For further validation, we obtained SARS CoV-2 antibody in a subset of participants and identified 10 additional participants who self-reported COVID-19 disease with antibody confirmation. The algorithm had an overall ROC AUC of 0.819 (95% CI [0.809, 0.830]), with a sensitivity of 90% and specificity of 80% in these additional participants. Finally, we observed substantial variation in accuracy based on age and biological sex. Findings highlight the importance of including temperature assessment, using continuous physiological features for alignment, and including diverse populations in algorithm development to optimize accuracy in COVID-19 detection from wearables.

12 August 2024 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
LBLauryn Keeler Bruce
Lauryn Keeler Bruce
DGDalila González
Dalila González
Subhasis DasguptaSubhasis Dasgupta
Subhasis Dasgupta
BSBenjamin Smarr
Benjamin Smarr
In the United States, normal-risk pregnancies are monitored with the recommended average of 14 prenatal visits. Check-ins every few weeks are the standard of care. This low time resolution and reliance on subjective feedback instead of direct physiological measurement, could be augmented by remote monitoring. To date, continuous physiological measurements have not been characterized across all of pregnancy, so there is little basis of comparison to support the development of the specific monitoring capabilities. Wearables have been shown to enable the detection and prediction of acute illness, often faster than subjective symptom reporting. Wearables have also been used for years to monitor chronic conditions, such as continuous glucose monitors. Here we perform a retrospective analysis on multimodal wearable device data (Oura Ring) generated across pregnancy within 120 individuals. These data reveal clear trajectories of pregnancy from cycling to conception through postpartum recovery. We assessed individuals in whom pregnancy did not progress past the first trimester, and found associated deviations, corroborating that continuous monitoring adds new information that could support decision-making even in the early stages of pregnancy. By contrast, we did not find significant deviations between full-term pregnancies of people younger than 35 and of people with “advanced maternal age”, suggesting that analysis of continuous data within individuals can augment risk assessment beyond standard population comparisons. Our findings demonstrate that low-cost, high-resolution monitoring at all stages of pregnancy in real-world settings is feasible and that many studies into specific demographics, risks, etc., could be carried out using this newer technology.

9 February 2022 in Vaccines
Verified
Journal Article
Open access
PDF file
AMAshley Mason
Ashley Mason
PKPatrick Kasl
Patrick Kasl
WHWendy Hartogensis
Wendy Hartogensis
JNJoseph L. Natale
Joseph L. Natale
SDStephan Dilchert
Stephan Dilchert
FHFrederick M. Hecht
Frederick M. Hecht
There is significant variability in neutralizing antibody responses (which correlate with immune protection) after COVID-19 vaccination, but only limited information is available about predictors of these responses. We investigated whether device-generated summaries of physiological metrics collected by a wearable device correlated with post-vaccination levels of antibodies to the SARS-CoV-2 receptor-binding domain (RBD), the target of neutralizing antibodies generated by existing COVID-19 vaccines. One thousand, one hundred and seventy-nine participants wore an off-the-shelf wearable device (Oura Ring), reported dates of COVID-19 vaccinations, and completed testing for antibodies to the SARS-CoV-2 RBD during the U.S. COVID-19 vaccination rollout. We found that on the night immediately following the second mRNA injection (Moderna-NIAID and Pfizer-BioNTech) increases in dermal temperature deviation and resting heart rate, and decreases in heart rate variability (a measure of sympathetic nervous system activation) and deep sleep were each statistically significantly correlated with greater RBD antibody responses. These associations were stronger in models using metrics adjusted for the pre-vaccination baseline period. Greater temperature deviation emerged as the strongest independent predictor of greater RBD antibody responses in multivariable models. In contrast to data on certain other vaccines, we did not find clear associations between increased sleep surrounding vaccination and antibody responses.

13 May 2024
Verified
Conference Paper
Closed access
ZZZhongyang Zhang
Zhongyang Zhang
SCShuyang Cui
Shuyang Cui
KCKaidong Chai
Kaidong Chai
HYHaowen Yu
Haowen Yu
Subhasis DasguptaSubhasis Dasgupta
Subhasis Dasgupta
TRTauhidur Rahman
Tauhidur Rahman
Dynamic Vision Sensor (DVS)-based solutions have recently garnered significant interest across various computer vision tasks, offering notable benefits in terms of dynamic range, temporal resolution, and inference speed. However, as a relatively nascent vision sensor compared to Active Pixel Sensor (APS) devices such as RGB cameras, DVS suffers from a dearth of ample labeled datasets. Prior efforts to convert APS data into events often grapple with issues such as a considerable domain shift from real events, the absence of quantified validation, and layering problems within the time axis. In this paper, we present a novel method for video-to-events stream conversion from multiple perspectives, considering the specific characteristics of DVS. A series of carefully designed losses helps enhance the quality of generated event voxels significantly. We also propose a novel local dynamic-aware timestamp inference strategy to accurately recover event timestamps from event voxels in a continuous fashion and eliminate the temporal layering problem. Results from rigorous validation through quantified metrics at all stages of the pipeline establish our method unquestionably as the current state-of-the-art (SOTA). The code can be found at bit.ly/v2ce.

1 December 2016
Verified
Conference Paper
Closed access
Subhasis DasguptaSubhasis Dasgupta
Subhasis Dasgupta
KCKevin Coakley
Kevin Coakley
AGAmarnath Gupta
Amarnath Gupta
Polystores, i.e., data management systems that use multiple stores for different data models, are gaining popularity. We are developing a polystore-based system called AWESOME to support social data analytics. The AWESOME polystore can support relational, semistructured, graph and text data and houses a Spark computation engine to produce derived data during ingestion. ADIL, the data ingestion language of AWESOME allows a user to flexibly specify the placement of original and derived data into and across component stores and the computation engine. The paper also outlines a number of optimization strategies for managing data placement in AWESOME.

1 November 2023 in Biology of Sex Differences
Verified
Journal Article
Open access
PDF file
LBLauryn Keeler Bruce
Lauryn Keeler Bruce
PKPatrick Kasl
Patrick Kasl
SSSeverine Soltani
Severine Soltani
VVVarun K. Viswanath
Varun K. Viswanath
WHWendy Hartogensis
Wendy Hartogensis
BSBenjamin Smarr
Benjamin Smarr
Background: Females have been historically excluded from biomedical research due in part to the documented presumption that results with male subjects will generalize effectively to females. This has been justified in part by the assumption that ovarian rhythms will increase the overall variance of pooled random samples. But not all variance in samples is random. Human biometrics are continuously changing in response to stimuli and biological rhythms; single measurements taken sporadically do not easily support exploration of variance across time scales. Recently we reported that in mice, core body temperature measured longitudinally shows higher variance in males than cycling females, both within and across individuals at multiple time scales. Methods: Here, we explore longitudinal human distal body temperature, measured by a wearable sensor device (Oura Ring), for 6 months in females and males ranging in age from 20 to 79 years. In this study, we did not limit the comparisons to female versus male, but instead we developed a method for categorizing individuals as cyclic or acyclic depending on the presence of a roughly monthly pattern to their nightly temperature. We then compared structure and variance across time scales using multiple standard instruments. Results: Sex differences exist as expected, but across multiple statistical comparisons and timescales, there was no one group that consistently exceeded the others in variance. When variability was assessed across time, females, whether or not their temperature contained monthly cycles, did not significantly differ from males both on daily and monthly time scales. Conclusions: These findings contradict the viewpoint that human females are too variable across menstrual cycles to include in biomedical research. Longitudinal temperature of females does not accumulate greater measurement error over time than do males and the majority of unexplained variance is within sex category, not between them.