28 June 2023 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Open access
ZWZhehui Wang
Zhehui Wang
CDChristophe Dujardin
Christophe Dujardin
MFMatthew S. Freeman
Matthew S. Freeman
AGAmanda E. Gehring
Amanda E. Gehring
JHJames F. Hunter
James F. Hunter
MZMariya Zhuravleva
Mariya Zhuravleva
Radiographic imaging and tomography (RadIT), which started with Röntgen’s seminal X-ray work in 1895, now include an increasing number of imaging and tomography (IT) modalities. In addition to the original absorption-based X-ray radiography, others include phase contrast X-ray imaging, coherent X-ray diffractive imaging, MeV X- and γ-ray radiography, X-ray computed tomography, proton IT, neutron IT, positron emission tomography (PET), high-energy electron radiography, and cosmic-ray muon tomography. Scintillators are widely used in RadIT as the detector frontend that converts ionizing radiation into signals and data. We give an overview of the status and needs of scintillator applications in RadIT. More than 160 kinds of scintillators were presented during the SCINT22 conference, and offered ample options for novel RadIT applications. New trends in scintillators for RadIT applications include inorganic and organic scintillator composites or heterostructures, liquid phase synthesized perovskites and single-crystal micrometer-thick films, use of multi-physics models and data science to guide scintillator and RadIT optimization, structural innovations such as photonic crystals, nano-scintillators enhanced by the Purcell effect, heterostructural scintillating fibers, and multilayer configurations. RadIT have also been recognized as powerful tools for scintillator discovery and development.

27 March 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Ethan StolenEthan Stolen
Ethan Stolen
RFRyan Fullarton
Ryan Fullarton
RHRain Hein
Rain Hein
RCRobin L. Conner
Robin L. Conner
LJLuiz G. Jacobsohn
Luiz G. Jacobsohn
DRDaniel Robertson
Daniel Robertson
Proton radiography is a promising development in proton therapy, and researchers are currently exploring optimal detector materials to construct proton radiography detector arrays. High-density glass scintillators may improve integrating-mode proton radiography detectors by increasing spatial resolution and decreasing detector thickness. We evaluated several new scintillators, activated with europium or terbium, with proton response measurements and Monte Carlo simulations, characterizing relative luminosity, ionization quenching, and proton radiograph spatial resolution. We applied a correction based on Birks’s analytical model for ionization quenching. The data demonstrate increased relative luminosity with increased activation element concentration, and higher relative luminosity for samples activated with europium. An increased glass density enables more compact detector geometries and higher spatial resolution. These findings suggest that a tungsten and gadolinium oxide-based glass activated with 4% europium is an ideal scintillator for testing in a full-size proton radiography detector.

15 July 2026 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
RGRachel B. Ger
Rachel B. Ger
MAMichael D. Armstrong
Michael D. Armstrong
DRDaniel Robertson
Daniel Robertson
Background: Quality assurance (QA) in radiation therapy is a critical component of ensuring accurate and consistent patient treatments, but many tasks are time consuming and rely on human visual acuity, which limits their accuracy. Purpose: We aimed to automate monthly mechanical QA tests, improve measurement accuracy and precision, and decrease inter‐user variability using a computer vision‐based quality assurance (CVQA) system. Methods: A custom marker board incorporating four ArUco markers was created along with a custom camera holder that mounted onto the gantry head. OpenCV was utilized to automate tests for couch translation, collimator and table angles, collimator and table walkout, optical distance indicator (ODI), and field size detection. A GUI was created to guide users through the tests, determine passing status of measurements based on MPPG8.b criteria, and display image captures to allow users to troubleshoot if needed. Reproducibility tests were taken across four days. The system was tested against manual measurements by graph paper or digital level for each test. Field sizes and ODI were read by 12 different physicists to determine human variability and comparisons for CVQA. Results: The CVQA system took 5 min to set up and 7 min to perform all tests. All field sizes, collimator/table angles, collimator/table walkout, and table translations were reproducible within 0.5 mm and 0.5°. ODI measurements were reproducible within 1 mm. Table travel, ODI, and walkout measurements agreed with manual measurements within 0.5 mm and 0.4°, except for vertical table motions that agreed within 0.9 mm due to the lens focus being optimized for the 100 cm SSD plane. The standard deviation between physicists for almost all symmetric and asymmetric jaws was larger than the reproducibility of CVQA. CVQA has been utilized for five years and has demonstrated ability to identify mechanical machine issues. Conclusions: CVQA successfully automates mechanical QA tasks, providing an efficient and precise system. CVQA is open source and freely available for academic institutions. Its adoption can improve workflow efficiency and consistency in clinical environments.

1 September 2026 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
ABAbram Bell
Abram Bell
JHJason M. Holmes
Jason M. Holmes
SBSam Beddar
Sam Beddar
DRDaniel Robertson
Daniel Robertson
Proton stereotactic radiosurgery requires validation of dose distributions and aperture shapes prior to patient treatment. Most two-dimensional (2D) detector arrays lack sufficient spatial resolution to adequately characterize these fields, and only sample the dose distribution at a single depth. In this study, a volumetric scintillator detector is evaluated for validation of small collimated proton fields. 2D projections of three-dimensional (3D) light distributions are measured with a digital camera, and ionization quenching is corrected using Monte Carlo-derived linear energy transfer calculations. The resulting projected dose distributions are compared to dose projections from the treatment planning system. The measured and calculated dose projections agreed with a Gamma passing rate (2%, 2mm) greater than 99%. This system demonstrates potential as a patient quality assurance tool for small, collimated proton fields.

1 January 2023
Verified
Conference Paper
Closed access
PDF file
DRDaniel Robertson
Daniel Robertson
ESEthan Stolen
Ethan Stolen
RFRyan Fullerton
Ryan Fullerton
UAUgur Akgun
Ugur Akgun
CFCharles-Antoine Collins Fekete
Charles-Antoine Collins Fekete
SBSam Beddar
Sam Beddar
High-density glass scintillators may improve integrating-mode proton radiography detectors by improving resolution and decreasing detector size. Five new scintillators were evaluated with measurements and Monte Carlo simulations, characterizing light output, ionization quenching, and spatial resolution.

20 December 2022 in arXiv
Verified
Preprint
Open access
PDF file
ZWZhehui Wang
Zhehui Wang
CDChristophe Dujardin
Christophe Dujardin
MFMatthew S. Freeman
Matthew S. Freeman
AGAmanda E. Gehring
Amanda E. Gehring
JHJames Hunter
James Hunter
Mariya ZhuravlevaMariya Zhuravleva
Mariya Zhuravleva
Scintillators are important materials for radiographic imaging and tomography (RadIT), when ionizing radiations are used to reveal internal structures of materials. Since its invention by R\"ontgen, RadIT now come in many modalities such as absorption-based X-ray radiography, phase contrast X-ray imaging, coherent X-ray diffractive imaging, high-energy X- and $\gamma-$ray radiography at above 1 MeV, X-ray computed tomography (CT), proton imaging and tomography (IT), neutron IT, positron emission tomography (PET), high-energy electron radiography, muon tomography, etc. Spatial, temporal resolution, sensitivity, and radiation hardness, among others, are common metrics for RadIT performance, which are enabled by, in addition to scintillators, advances in high-luminosity accelerators and high-power lasers, photodetectors especially CMOS pixelated sensor arrays, and lately data science. Medical imaging, nondestructive testing, nuclear safety and safeguards are traditional RadIT applications. Examples of growing or emerging applications include space, additive manufacturing, machine vision, and virtual reality or `metaverse'. Scintillator metrics such as light yield and decay time are correlated to RadIT metrics. More than 160 kinds of scintillators and applications are presented during the SCINT22 conference. New trends include inorganic and organic scintillator heterostructures, liquid phase synthesis of perovskites and $\mu$m-thick films, use of multiphysics models and data science to guide scintillator development, structural innovations such as photonic crystals, nanoscintillators enhanced by the Purcell effect, novel scintillator fibers, and multilayer configurations. Opportunities exist through optimization of RadIT with reduced radiation dose, data-driven measurements, photon/particle counting and tracking methods supplementing time-integrated measurements, and multimodal RadIT.