Ethan Stolen

Ethan Stolen

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Ethan StolenEthan Stolen
Ethan Stolen
RFRyan Fullarton
Ryan Fullarton
RHRain Hein
Rain Hein
RCRobin L. Conner
Robin L. Conner
LJLuiz G. Jacobsohn
Luiz G. Jacobsohn
DRDaniel Robertson
Daniel Robertson
Proton radiography is a promising development in proton therapy, and researchers are currently exploring optimal detector materials to construct proton radiography detector arrays. High-density glass scintillators may improve integrating-mode proton radiography detectors by increasing spatial resolution and decreasing detector thickness. We evaluated several new scintillators, activated with europium or terbium, with proton response measurements and Monte Carlo simulations, characterizing relative luminosity, ionization quenching, and proton radiograph spatial resolution. We applied a correction based on Birks’s analytical model for ionization quenching. The data demonstrate increased relative luminosity with increased activation element concentration, and higher relative luminosity for samples activated with europium. An increased glass density enables more compact detector geometries and higher spatial resolution. These findings suggest that a tungsten and gadolinium oxide-based glass activated with 4% europium is an ideal scintillator for testing in a full-size proton radiography detector.

2 August 2024 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
PDF file
JSJames J Sohn
James J Sohn
HKHaram Kim
Haram Kim
Ethan StolenEthan Stolen
Ethan Stolen
GCGibson Chidel
Gibson Chidel
SJSung Jang
Sung Jang
BLBo Lu
Bo Lu
Purpose. Secondary skin collimation (SSC) is essential for shielding normal tissues near tumors during electron and orthovoltage radiation treatments. Traditional SSC fabrication methods, such as crafting in-house lead sheets, are labor-intensive and produce SSCs with low geometric accuracy. This study introduces a workflow that integrated 3D scanning and 3D printing technologies with an in-house mold process, enabling the production of patient-specific SSCs within six hours. Methods. An anthropomorphic head phantom was scanned with a handheld 3D scanner. The resulting scan data was imported into 3D modeling software for design. The completed model was exported to a 3D printer as a printable file. Subsequently, molten Cerrobend was poured into the mold and allowed to set, completing the SSC production. Geometric accuracy was assessed using CT images, and the shielding effectiveness was evaluated through film dosimetry. Results. The 3D printed mold achieved submillimeter accuracy (0.5 mm) and exhibited high conformity to the phantom surface. It successfully endured the weight and heat of the Cerrobend during pouring and curing. Dosimetric analysis conducted with radiochromic film demonstrated good agreement between the measured and expected attenuation values of the SSC slab, within ±3%. Conclusions. This study presents a proof of concept for novel mold room workflows that produce patient-specific SSCs within six hours, a significant improvement over the traditional SSC fabrication process, which takes 2–3 days. The submillimeter accuracy and versatility of 3D scanning and printing technologies afford greater design freedom and enhanced delivery accuracy for cases involving irregular geometries.

30 August 2024 in Technical Innovations & Patient Support in Radiation Oncology
Verified
Journal Article
Open access
SSSiddhant Sen
Siddhant Sen
Ethan StolenEthan Stolen
Ethan Stolen
JCJaehee Chun
Jaehee Chun
JKJin Sung Kim
Jin Sung Kim
JSJames J. Sohn
James J. Sohn
Due to anatomical changes between pre-planning and implantation, there exists a need for tools that can streamline the adjustment of needle and seed configurations in low dose rate brachytherapy for prostate cancer. Specifically, upon taking a second ultrasound on the day of treatment, the distribution of seeds and needles will differ drastically from the original plan. Clinics that employ this method must then spend time and resources to generate a workflow to manipulate the original configuration to the new configuration. ONCOSEED extracts data from VariSeed treatment plans, calculating a labor score (LScore) to optimize adjustments to needle configurations. A case study of three simulated VariSeed treatment plans was used to compare the ONCOSEED software to the manual method of generating a workflow. In the same method that was used at the authors' clinic, several assistants annotated by hand the original plan to convert it to the new plan. The time taken to do so was recorded and compared to the runtime of the software when generating a workflow for the same plan. Results showed that ONCOSEED was on average 28 times faster than generating a workflow by hand. ONCOSEED enhances the efficiency of seed replacement in LDR brachytherapy, promoting the adoption of adaptive brachytherapy practices.

27 May 2025 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
PDF file
Ethan StolenEthan Stolen
Ethan Stolen
TWTianming Wu
Tianming Wu
JSJoseph B Schulz
Joseph B Schulz
LALunya Allie
Lunya Allie
CSCaleb Song
Caleb Song
JSJames J Sohn
James J Sohn
Purpose. Total body irradiation (TBI) is a critical component in the treatment of hematological malignancies, but it carries a risk of radiation-induced lung damage. Traditional lung shields, typically made of lead or Cerrobend, are used to protect lung tissue during TBI. However, these shields require manual fabrication, present toxicity concerns, and are difficult to reproduce in the precise geometry needed for each individual patient. This study investigates the feasibility of 3D-printed bronze-polylactic acid (PLA) lung shields as a non-toxic, customizable alternative to conventional shields in TBI procedures. Materials and Methods. Bronze-PLA lung shields were 3D-printed using a PLA filament with 60% bronze powder by weight. Two thicknesses of 1.8 cm and 3.3 cm were tested. Radiation transmission was measured using a Varian TrueBeam linear accelerator (6 MV and 15 MV photon beams) at isocenter (90 cm source-to-axis distance, SAD) and extended field setup (430 cm source-to-surface distance, SSD). Measurements were repeated with a conventional wax-lead shield for comparison. Results. At 100 cm SAD and 6 MV, the 1.8 cm bronze-PLA shield transmitted 92.12% (standard error, SE = 0.03%), while the thicker (3.3 cm) bronze-PLA shield reduced transmission to 77.08% (SE = 0.02%). Under similar conditions, the wax-lead shield transmitted 86.43% (SE = 0.13%). For 15 MV beams, both the wax-lead and bronze-PLA shields exhibited higher transmission, with the 3.3 cm bronze-PLA shield providing improved attenuation relative to the thinner shield. At the extended SAD, the thinner bronze-PLA shield transmitted more than the wax-lead block, but increasing thickness consistently improved attenuation. Conclusion. The 3D-printed bronze-PLA lung shields demonstrate promising potential in TBI procedures, offering advantages in customization, reduced toxicity, and improved workflow efficiency. While differences in transmission characteristics were observed, particularly at higher energies and extended SDD, these findings provide a foundation for further optimization of 3D-printed shielding for TBI protocols.

1 October 2025 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
JSJames J Sohn
James J Sohn
Ethan StolenEthan Stolen
Ethan Stolen
SSSiddhant Sen
Siddhant Sen
APAmritha Praveen
Amritha Praveen
JPJeonghoon Park
Jeonghoon Park
Accurate fabrication of custom boluses is essential in radiation therapy to ensure optimal dose delivery to superficial tumors, particularly in anatomically complex regions. This study presents a novel method that utilizes spectral mesh flattening (SMF) to unfold three-dimensional (3D) virtual bolus designs into two-dimensional (2D) contours, aiming to enhance the fabrication workflow and improve reproducibility in bolus shape and placement. Using computed tomography (CT) scans of a phantom with radiopaque wires delineating target regions such as the nose, chin, and ear, virtual boluses of 0.5 cm thickness were designed within a treatment planning system. The 3D mesh geometries of these boluses were then exported and processed using a custom-developed software tool, ONCOFLAT, which implements the SMF algorithm to generate 2D representations while minimizing geometric distortion. These 2D contours were printed and used as cutting guides for the fabrication of flat bolus materials. After fabrication, the boluses were applied to the phantom and rescanned, and their accuracy was assessed by comparing the physical boluses to the original virtual designs using the Dice Similarity Coefficient (DSC) and the Hausdorff distance. The SMF algorithm successfully unfolded complex 3D geometries into 2D contours, and the ONCOFLAT software enabled a streamlined process that reduced the total design-to-fabrication time to under five minutes. The fabricated boluses closely conformed to the intended anatomical surfaces, with DSC values ranging from 0.59 to 0.62 and average Hausdorff distances below 1.3 mm. The 95% Hausdorff distances ranged from 3.50 mm to 4.22 mm. These results demonstrate that the integration of SMF within ONCOFLAT offers a fast, reproducible method for fabricating patient-specific boluses for complex anatomy. The approach shows promise in improving the consistency and effectiveness of dose delivery in radiation therapy, representing a meaningful advancement in personalized treatment planning.

7 February 2026 in Technical Innovations & Patient Support in Radiation Oncology
Verified
Journal Article
Open access
Ethan StolenEthan Stolen
Ethan Stolen
SYSridhar Yaddanapudi
Sridhar Yaddanapudi
HQHelen Qian
Helen Qian
SYSang Kyun Yoo
Sang Kyun Yoo
BLBo Lu
Bo Lu
JSJames J. Sohn
James J. Sohn
Carbon ion radiotherapy (CIRT) facilities face scheduling challenges due to multiple treatment rooms sharing a single synchrotron, leading to extended patient wait times and reduced efficiency. This study developed and evaluated an optimization tool for patient scheduling in multi-gantry CIRT facilities to minimize in-room patient wait time and maximize patient throughput. A simulation–optimization model was created to emulate patient flow in a facility with one fixed-beam and three gantry rooms. We developed a genetic algorithm (GA) to balance competing objectives like wait times, room utilization, and treatment priority. Its performance was evaluated against baseline scheduling and a Bayesian optimization (BO) approach, using metrics of average in-room wait time and algorithm execution speed. Robustness was tested across various scenarios, including equipment downtime. The GA reduced average patient wait times by 17% (from 0.47 to 0.39 min) compared to baseline. BO performed significantly better, achieving a 92% reduction (to 0.04 min). While GA converged faster (3 min), BO required more iterations to converge, thereby taking longer (7 min), but achieving much greater reduction in average patient wait times. In 100 independent test scenarios, the BO approach significantly reduced wait times in 100% of the simulations, compared to 19% for the GA. Both algorithms maintained robust performance across diverse conditions, demonstrating their reliability. Analysis of outliers (N = 100) showed that BO significantly reduced the maximum patient wait time from 3.52 to 1.33 min (p < 0.001), minimizing clinically relevant extremes. This application of scheduling optimization to the unique constraints of CIRT shows potential for improving efficiency at CIRT facilities. While requiring minutes rather than seconds to converge, the BO algorithm effectively eliminates immobilized wait times, making it a powerful tool for daily schedule optimization. Future research will focus on validation with empirical data from operational CIRT centers.