Non-invasive core body temperature (CBT) measurements using temperature and heat-flux have become popular in health, sports, work safety, and general well-being applications. This research aimed to evaluate two commonly used sensor designs: those that combine heat flux and temperature sensors, and those with four temperature sensors. We used analytical methods, particularly uncertainty analysis calculus and Monte Carlo simulations, to analyse measurement accuracy, which depends on the accuracy of the temperature and flux sensors, mechanical construction parameters (such as heat transfer coefficient), ambient air temperature, and CBT values. The results show the relationship between the accuracy of each measurement method variant and various sensor parameters, indicating their suitability for different scenarios. All measurement variants showed unstable behaviour around the point where ambient temperature equals CBT. The ratio of the heat transfer coefficients of the dual-heat flux (DHF) sensor’s channels impacts the CBT estimation uncertainty. An analysis of the individual components of uncertainty in CBT estimates reveals that the accuracy of temperature sensors significantly impacts the overall uncertainty of the CBT measurement. We also calculated the theoretical limits of measurement uncertainty, which varied depending on the method variant and could be as low as 0.05 °C.
1 January 2017 in Ultrasound in Medicine & Biology
Effect of the out-of-plane (OOP) movement amplitude on estimates of global displacements (radial, circumferential) and strains (radial $\varepsilon _{\mathrm {R}}$ , circumferential $\varepsilon _{\mathrm {C}}$ ) was studied in an ellipsoidal model of the left ventricle using finite-element modeling (FEM), synthetic ultrasonic data, and short-axis view. This effect was assessed using median of the absolute relative error (RE) of the global parameters. FEM provided node displacements for synthetic ultrasonic data and reference data generation. Displacements were estimated using block-matching (BM) and B-spline (BS) methods. FEM-derived data analysis, free from errors resulting from speckle tracking, indicated that the tissue motion introduced REs of global strain estimates below 4.5%. The effect of the OOP motion amplitude on strain estimates was strain specific and depended on the displacement estimation method. In the case of $\varepsilon _{\mathrm {C}}$ , the increase of the OOP amplitude resulted in quasi-linear increase of the RE from approximately 10% to 15%. The modulus of the end-systolic (ES) errors of the $\varepsilon _{\mathrm {C}}$ estimates almost linearly increased with increasing OOP amplitude approximately from 10% to 16%. REs of the $\varepsilon _{\mathrm {R}}$ estimate were close to 80% and 40%, respectively, in the case of the BM and BS methods, and increased with increasing OOP amplitude. The modulus of the ES errors of the $\varepsilon _{\mathrm {R}}$ estimates in the case of the BS method was about −40% and showed low sensitivity to the OOP amplitude; in the BM case, these errors varied approximately from −70% to −58% for OOP amplitude from 0 to 15 mm.