Aleksandra Wilczewska

Aleksandra Wilczewska

Auto-generated profile, based on publicly available information

Aleksandra Wilczewska

Institute of Metrology and Biomedical Engineering, Faculty of Mechatronics , Warsaw University of Technology , Warsaw , Poland

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 July 2018 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
JŻJakub Żmigrodzki
Jakub Żmigrodzki
SCSzymon Cygan
Szymon Cygan
AWAleksandra Wilczewska
Aleksandra Wilczewska
KKKrzysztof Kaluzynski
Krzysztof Kaluzynski
Effect of the out-of-plane (OOP) movement amplitude on estimates of global displacements (radial, circumferential) and strains (radial $\varepsilon _{\mathrm {R}}$ , circumferential $\varepsilon _{\mathrm {C}}$ ) was studied in an ellipsoidal model of the left ventricle using finite-element modeling (FEM), synthetic ultrasonic data, and short-axis view. This effect was assessed using median of the absolute relative error (RE) of the global parameters. FEM provided node displacements for synthetic ultrasonic data and reference data generation. Displacements were estimated using block-matching (BM) and B-spline (BS) methods. FEM-derived data analysis, free from errors resulting from speckle tracking, indicated that the tissue motion introduced REs of global strain estimates below 4.5%. The effect of the OOP motion amplitude on strain estimates was strain specific and depended on the displacement estimation method. In the case of $\varepsilon _{\mathrm {C}}$ , the increase of the OOP amplitude resulted in quasi-linear increase of the RE from approximately 10% to 15%. The modulus of the end-systolic (ES) errors of the $\varepsilon _{\mathrm {C}}$ estimates almost linearly increased with increasing OOP amplitude approximately from 10% to 16%. REs of the $\varepsilon _{\mathrm {R}}$ estimate were close to 80% and 40%, respectively, in the case of the BM and BS methods, and increased with increasing OOP amplitude. The modulus of the ES errors of the $\varepsilon _{\mathrm {R}}$ estimates in the case of the BS method was about −40% and showed low sensitivity to the OOP amplitude; in the BM case, these errors varied approximately from −70% to −58% for OOP amplitude from 0 to 15 mm.

16 January 2022 in Ultrasonic Imaging
Verified
Journal Article
Closed access
PDF file
AWAleksandra Wilczewska
Aleksandra Wilczewska
SCSzymon Cygan
Szymon Cygan
JŻJakub Żmigrodzki
Jakub Żmigrodzki
Although the two dimensional Speckle Tracking Echocardiography has gained a strong position among medical diagnostic techniques in cardiology, it still requires further developments to improve its repeatability and reliability. Few works have attempted to incorporate the left ventricle segmentation results in the process of displacements and strain estimation to improve its performance. We proposed the use of mask information as an additional penalty in the elastic image registration based displacements estimation. This approach was studied using a short axis view synthetic echocardiographic data, segmented using an active contour method. The obtained masks were distorted to a different degree, using different methods to assess the influence of the segmentation quality on the displacements and strain estimation process. The results of displacements and circumferential strain estimations show, that even though the method is dependent on the mask quality, the potential loss in accuracy due to the poor segmentation quality is much lower than the potential accuracy gain in cases where the segmentation performs well.

1 September 2024 in Polish Journal of Medical Physics And Engineering
Verified
Journal Article
Open access
PDF file
SCSzymon Cygan
Szymon Cygan
AWAleksandra Wilczewska
Aleksandra Wilczewska
TKTomasz Kubik
Tomasz Kubik
MAMartino Alessandrini
Martino Alessandrini
Introduction: Due to its simplicity, block-matching is a popular motion-tracking method used in speckle-tracking echocardiography. Improvement of its robustness and accuracy is thus of prime interest. Although it seems plausible that the quality of block matching-based tracking depends on the local properties of image data, and thus, it should be possible to assess in advance how well certain portions of the image data are suited for displacement estimation, the potential relationship has not been studied extensively. Material and methods: This study aimed to search for a relationship between selected features of echocardiographic data and the quality of local displacement estimation. The study used a 3D synthetic B-mode imaging sequence data with known ground truth. Frame-to-frame displacements were estimated for 9856 points in five different frame pairs with mean inter-frame displacements of 0.15, 0.87, 2, 3.02, and 3.84 mm. In each case, tracking errors were evaluated against thirteen grayscale image features, the displacement’s magnitudes, and the normalized cross-correlation (NCX) values. Additionally, a multi-variable regression model was applied to test the combined ability of the proposed features to predict tracking quality. Results: Median tracking error magnitudes were 0.06, 0.13, 0.28, 0.74, and 1.5 mm for each image pair. Weak correlation between errors and individual data features was found only in the case of 3 features: NCX (Pearson’s correlation coefficients in the range of −0.366 to −0.223), number of speckles within the kernel (−0.283, −0.282, and −0.214 for three lowest deformations) and mean of the 3D gradient (−0.252, −0.237 and −0.25). The regression model, however, provided significant prediction improvement with R2 exceeding 0.5. Conclusions: In conclusion, only a weak relationship between the individual investigated kernel features and tracking accuracy has been established, but their combined strength can be assessed as at least moderate.