Hangue Park

Dr. Hangue Park

Department of Electrical and Computer Engineering, Texas A&M University, 400 Bizzell St, College Station, TX 77843, USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2025 in Science Advances
Verified
Journal Article
Open access
Md. Saifur RahmanMd. Saifur Rahman
Md. Saifur Rahman
ASAhnsei Shon
Ahnsei Shon
RJRose Joseph
Rose Joseph
APAnton Pavlov
Anton Pavlov
ASAlex Stefanov
Alex Stefanov
Limei TianLimei Tian
Limei Tian
Conductive hydrogels are emerging as promising materials for electronic implants owing to their favorable mechanical and electrical properties. Poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) hydrogels are particularly attractive, but their preparation often requires toxic additives. Here, we introduced a nutritive sweetener, d -sorbitol, as a nontoxic additive to create soft and stretchable PEDOT:PSS conductive hydrogels. These hydrogels exhibit mechanical properties comparable with biological tissues, reducing adverse immune responses. The hydrogels can be patterned on elastic substrates using a simple, low-cost micromolding technique to fabricate soft and stretchable implantable devices for electrical stimulation and recording. The hydrogel electrodes show much lower electrochemical impedance and higher charge storage and injection capacity compared to platinum electrodes. In addition, the properties of hydrogels and devices remain stable after long-term storage and exposure to extreme conditions. We demonstrate the use of soft hydrogel-based electronic devices for effective electrical stimulation and high-quality electrical recordings in live animal models.

3 May 2021 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
RRRohit Rangwani
Rohit Rangwani
Hangue ParkHangue Park
Hangue Park
Background: Neurotraumas or neurodegenerative diseases often result in proprioceptive deficits, which makes it challenging for the nervous system to adapt to the compromised sensorimotor conditions. Also, in human machine interactions, such as prosthesis control and teleoperation, proprioceptive mismatch limits accuracy and intuitiveness of controlling active joints in robotic agents. To address these proprioceptive deficits, several invasive and non-invasive approaches like vibration, electrical nerve stimulation, and skin stretch have been introduced. However, proprioceptive modulation is still challenging as the current solutions have limitations in terms of effectiveness, usability, and consistency. In this paper, we propose a new way of modulating proprioception using transcutaneous electrical stimulation. We hypothesized that transcutaneous electrical stimulation on elbow flexor muscles will induce illusion of elbow joint extension. Method: Eight healthy human subjects participated in the study to test the hypothesis. Transcutaneous electrodes were placed on different locations targeting elbow flexor muscles on human subjects and experiments were conducted to identify the best locations for electrode placement, and best electrical stimulation parameters, to maximize induced proprioceptive effect. Arm matching experiments and Pinocchio illusion test were performed for quantitative and qualitative analysis of the observed effects. One-way repeated ANOVA test was performed on the data collected in arm matching experiment for statistical analysis. Results: We identified the best location for transcutaneous electrodes to induce the proprioceptive illusion, as one electrode on the muscle belly of biceps brachii short head and the other on the distal myotendinous junction of brachioradialis. The results for arm-matching and Pinocchio illusion tests showed that transcutaneous electrical stimulation using identified electrode location and electrical stimulation parameters evoked the illusion of elbow joint extension for all eight subjects, which supports our hypothesis. On average, subjects reported 6.81° angular illusion of elbow joint extension in arm-matching tests and nose elongated to 1.78 × height in Pinocchio illusion test. Conclusions: Transcutaneous electrical stimulation, applied between the the synergistic elbow flexor muscles, consistently modulated elbow joint proprioception with the illusion of elbow joint extension, which has immense potential to be translated into various real-world applications, including neuroprosthesis, rehabilitation, teleoperation, mixed reality, and etc.

13 January 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ZZZiqi Zhao
Ziqi Zhao
MYMinku Yeo
Minku Yeo
SMStefan Manoharan
Stefan Manoharan
SRSeok Chang Ryu
Seok Chang Ryu
Hangue ParkHangue Park
Hangue Park
For teleoperation tasks requiring high control accuracy, it is essential to provide teleoperators with information on the interaction between the end effector and the remote environment. Real-time imaging devices have been widely adopted, but it delivers limited information, especially when the end effectors approach the target following the line-of-sight. In such situations, teleoperators rely on the perspective at the screen and can apply high force unintentionally at the initial contact. This research proposes to deliver the distance information at teleoperation to the fingertips of teleoperators, i.e., proximity sensation. Transcutaneous electrical stimulation was applied onto the fingertips of teleoperators, with the pulsing frequency inversely proportional to the distance. The efficacy of the proximity sensation was evaluated by the initial contact force during telerobotic pinch in three sensory conditions: vision only, vision + visual assistance (distance on the screen), and vision + proximity sensation. The experiments were repeated at two viewing angles: 30–60° and line-of-sight, for eleven healthy human subjects. For both cases, the initial contact force could be significantly reduced by either visual assistance (20–30%) or the proximity sensation (60–70%), without additional processing time. The proximity sensation is two-to-three times more effective than visual assistance regarding the amount of force reduction.

24 February 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JPJaekwan K. Park
Jaekwan K. Park
NDNicolaas E. P. Deutz
Nicolaas E. P. Deutz
CCClayton L. Cruthirds
Clayton L. Cruthirds
SSarah K. Kirschner
Sarah K. Kirschner
Hangue ParkHangue Park
Hangue Park
MEMariëlle P.K.J Engelen
Mariëlle P.K.J Engelen
Reduced balance function has been observed during balance challenging conditions in the chronic obstructive pulmonary disease (COPD) population and is associated with an increased risk of falls. This study aimed to examine postural balance during quiet standing with eyes open and functional balance in a heterogeneous group of COPD and non-COPD (control) subjects, and to identify risk factors underlying balance impairment using a large panel of methods. In COPD and control subjects, who were mostly overweight and sedentary, postural and functional balance were assessed using center-of-pressure displacement in anterior-posterior (AP) and medio-lateral (ML) directions, and the Berg Balance Scale (BBS), respectively. COPD showed 23% greater AP sway velocity (p = 0.049). The presence of oxygen therapy, fat mass, reduced neurocognitive function, and the presence of (pre)diabetes explained 71% of the variation in postural balance in COPD. Transcutaneous oxygen saturation, a history of exacerbation, and gait speed explained 83% of the variation in functional balance in COPD. Neurocognitive dysfunction was the main risk factor for postural balance impairment in the control group. This suggests that specific phenotypes of COPD patients can be identified based on their type of balance impairment.

22 March 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JKJeonghee Kim
Jeonghee Kim
Youngjib HamYoungjib Ham
Youngjib Ham
Hangue ParkHangue Park
Hangue Park
To minimize the excavation damage of underground pipelines, in this article, we propose to provide real-time feedback to operators by monitoring the distance information from the underground pipeline. Despite multiple efforts to locate underground ferromagnetic pipelines using the magnetic anomaly detection, it has not been implemented in real-time excavation operations due to low signal-to-noise ratios, unknown external magnetic interference (EMI), and high computational power. To address these limitations, we propose an approach to locating a custom-designed wireless sensor system on the excavator bucket to increase accuracy of real-time distance estimation with efficient EMI cancelation. We present the system using a 14:1 lab-scaled excavator and six sizes of ferromagnetic pipes. To create a distance estimation model of each pipe, we measure the magnetic anomaly caused by ferromagnetic pipes from eight distances (from 5 to 75 mm, spaced 10 mm apart). The wireless system with the localization algorithm successfully estimates the distance between the sensor and the pipe with a less than 4.38 ± 1.62 mm error overall. This pilot study shows that the proposed system with the localization algorithm is able to accurately locate pipes. This will lay the foundation for providing accurate spatial information, and ultimately prevent critical excavation/drilling damage at construction sites.

16 April 2021 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
Ahnsei ShonAhnsei Shon
Ahnsei Shon
KBKiralyn Brakel
Kiralyn Brakel
Michelle HookMichelle Hook
Michelle Hook
Hangue ParkHangue Park
Hangue Park
Plantar cutaneous feedback plays an important role in stable and efficient gait, by modulating the activity of ankle dorsi-and plantar-flexor muscles. However, central and peripheral nervous trauma often decrease plantar cutaneous feedback and/or interneuronal excitability in processing the plantar cutaneous feedback. In this study, we tested if a fully implantable neural recording and stimulation system could augment plantar cutaneous feedback. Electromyograms were recorded from the medial gastrocnemius muscle for stance phase detection, while biphasic stimulation pulses were applied to the distal-tibial nerve during the stance phase to augment plantar cutaneous feedback. A Bluetooth low energy and a Qi-standard inductive link were adopted for wireless communication and wireless charging, respectively. To test the operation of the system, one intact rat walked on a treadmill with the electrical system implanted into its back. Leg kinematics were recorded to identify the stance phase. Stimulation was applied, with a 250-ms onset delay from stance onset and 200-ms duration, resulting in the onset at 47.58±2.82% of stance phase and the offset at 83.49±4.26% of stance phase (Mean±SEM). The conduction velocity of the compound action potential (31.2 m/s and 41.6 m/s at 1i,zT and 2i,zT, respectively) suggests that the evoked action potential was characteristic of an afferent volley for cutaneous feedback. We also demonstrated successful wireless charging and system reset functions. The experimental results suggest that the presented implantable system can be a valuable neural interface tool to investigate the effect of plantar cutaneous augmentation on gait in a rat model.