Francisco Arredondo

Dr. Francisco Arredondo

Departamento de Ingeniería Eléctrica, Universidad Carlos III de Madrid, Leganés, Spain
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2020 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
Francisco ArredondoFrancisco Arredondo
Francisco Arredondo
PLPablo Ledesma
Pablo Ledesma
ECEdgardo D. Castronuovo
Edgardo D. Castronuovo
MAMohammadamin Aghahassani
Mohammadamin Aghahassani
This paper proposes a Transient Stability Constrained Optimal Power Flow (TSCOPF) formulation that models non-synchronous renewable generation equipped with synthetic inertia. The proposed optimization problem calculates the optimal operating point of the system, accommodating high shares of non-synchronous renewable generation while ensuring transient stability in the event of critical incidents. Synthetic inertia controllers are used to improve the dynamic stability of the system in cases of very high share of renewable generation. The proposed tool is tested in the North-West Spanish system, a network with a high penetration of wind energy that causes a reduction in the total system inertia. The results of the study show that 1) synthetic inertia in renewable power plants can diminish electromechanical oscillations after a severe contingency, reducing the cost of ensuring transient stability; 2) using synthetic inertia the system becomes more stable when conventional generation is decommissioned following de-carbonization and renewable promotion policies; and 3) the proposed model can be used to calculate the parameters of the synthetic inertia control.

1 January 2017 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
PLPablo Ledesma
Pablo Ledesma
ICIgnacio Antonio Calle
Ignacio Antonio Calle
ECEdgardo D. Castronuovo
Edgardo D. Castronuovo
Francisco ArredondoFrancisco Arredondo
Francisco Arredondo
Transient stability constrained optimal power flow (TSCOPF) is a non‐linear optimisation problem used to perform economic dispatches while ensuring TS. This study proposes a multi‐contingency TSCOPF model that retains the dynamics of all generators and includes a transient synchronous generator fourth‐order dq ‐axis model. A program is developed that automatically reads the system data from standard files, builds the multiple‐contingency TSCOPF model on a high‐level modelling system and solves it using a non‐heuristic interior point algorithm. This approach facilitates the application of the model to a variety of systems and scenarios. A TSC based on the speed deviation instead of the rotor angle is proposed. Results obtained on several standard systems are shown. The proposed method is applied to the northwest Spanish transmission system to obtain an optimised dispatch that ensures TS after any of a number of faults, and to assess the economic impact of fault‐clearing times at different substations.

1 January 2019 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
Francisco ArredondoFrancisco Arredondo
Francisco Arredondo
PLPablo Ledesma
Pablo Ledesma
ECEdgardo D. Castronuovo
Edgardo D. Castronuovo

11 March 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JAJose Luis Rodriguez Amenedo
Jose Luis Rodriguez Amenedo
MMMiguel E. Montilla-DJesus
Miguel E. Montilla-DJesus
Santiago ArnaltesSantiago Arnaltes
Santiago Arnaltes
Francisco ArredondoFrancisco Arredondo
Francisco Arredondo
This paper presents a comprehensive RMS-based phasorial model of an E-STATCOM with grid-forming (GFM) control, designed to improve power system stability in isolated grids. Unlike previous approaches, this model integrates a governor with an internal power system stabilizer (PSS) and an active current limiter (ACL) to enhance frequency regulation and mitigate oscillations. Additionally, an exciter with a nonlinear modulation function is introduced to optimize voltage regulation and reactive power support. A detailed conventional supercapacitor (SC) model is also incorporated, enabling dynamic DC-voltage control based on active power variations, improving frequency stability. The proposed E-STATCOM RMS model includes algebraic equations, dynamic governor and exciter models, supercapacitor-based energy storage control, and an advanced current-limiting strategy. Simulations are conducted on the Fuerteventura–Lanzarote (Canary Islands, Spain) power system, comparing the E-STATCOM with a synchronous condenser (SynCon) in frequency response, voltage regulation, and fault performance. The results show that the E-STATCOM improves frequency stabilization and energy efficiency while complying with grid codes. This study introduces a novel RMS-based modeling approach for GFM E-STATCOMs, bridging the gap between theoretical phasorial analysis and real-world applications. The findings confirm that E-STATCOMs are a viable alternative to SynCons, enhancing grid stability in high-renewable-penetration systems.

7 March 2019 in Energies
Verified
Journal Article
Open access
PDF file
Francisco ArredondoFrancisco Arredondo
Francisco Arredondo
ECEdgardo D. Castronuovo
Edgardo D. Castronuovo
PLPablo Ledesma
Pablo Ledesma
Zbigniew LeonowiczZbigniew Leonowicz
Zbigniew Leonowicz
The optimization of the operation of power systems including steady state and dynamic constraints is efficiently solved by Transient Stability Constrained Optimal Power Flow (TSCOPF) models. TSCOPF studies extend well-known optimal power flow models by introducing the electromechanical oscillations of synchronous machines. One of the main approaches in TSCOPF studies includes the discretized differential equations that represent the dynamics of the system in the optimization model. This paper analyzes the impact of different implicit and explicit numerical integration methods on the solution of a TSCOPF model and the effect of the integration time step. In particular, it studies the effect on the power dispatch, the total cost of generation, the accuracy of the calculation of electromechanical oscillations between machines, the size of the optimization problem and the computational time.

21 November 2017 in Energies
Verified
Journal Article
Open access
PDF file
PLPablo Ledesma
Pablo Ledesma
Francisco ArredondoFrancisco Arredondo
Francisco Arredondo
ECEdgardo D. Castronuovo
Edgardo D. Castronuovo
The increasing penetration of non-synchronous, renewable energy in modern power systems displaces synchronous generation and affects transient stability. This is just one of the factors that has led to preventive curtailment of renewable energy sources in an increasing number of electrical grids. Transient stability constrained optimal power flow (OPF) techniques provide a tool to optimize the dispatch of power systems while ensuring a secure operation. This work proposes a transient stability-constrained OPF model that includes non-synchronous generation with fault ride-through capability and reactive support during voltage dips. The model is applied it to the IEEE 39 Bus benchmark test case and to the power system of the Spanish island of Tenerife, and solved using the open-source library IPOPT that implements a primal-dual interior point algorithm. The solution of the model makes it possible to optimize the dispatch of conventional plants and the curtailment of non-synchronous generation, as well as to explore methods to reduce generation cost. Fault ride-through capability, synchronous inertia and fault clearing times are identified as useful tools to reduce the curtailment of non-synchronous generation, especially during periods of low load and high availability of renewable energy sources.