Hongchun Shu

Hongchun Shu


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 February 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
HSHongchun Shu
Hongchun Shu
XLXuhan Liu
Xuhan Liu
XTXincui Tian
Xincui Tian
In terms of single-ended fault location for hybrid distribution lines, the most significant challenge is in the identification of the fault section and reflected wave from the fault point. Based on this, in this paper we introduce a new fault- section-location identification scheme for hybrid distribution feeders with only single-ended measurement. With the prior morphological spectrum-based fault-section identification technique, a location function is then built by the forward and backward traveling-wave components to describe the characteristic distribution of the traveling wave along the line. With the application of two-dimensional information (which is about time and space) of the traveling wave, it is simpler to locate the actual point of failure. The proposed scheme is investigated under different fault locations, fault resistances, sampling rates, fault inception angles, fault types, etc. The influences of immeasurable voltage traveling wave, adjacent sound lines, and measurable joint point are also investigated. Simulation results confirm the feasibility of the fault-location scheme for all test cases.

25 July 2017 in Energies
Verified
Journal Article
Open access
PDF file
JDJun Dong
Jun Dong
SLShengnan Li
Shengnan Li
SWShuijun Wu
Shuijun Wu
THTingyi He
Tingyi He
Bo YangBo Yang
Bo Yang
JYJilai Yu
Jilai Yu
The large-scale penetration of wind power might lead to degradation of the power system stability due to its inherent feature of randomness. Hence, proper control designs which can effectively handle various uncertainties become very crucial. This paper designs a novel robust passive control (RPC) scheme of a doubly-fed induction generator (DFIG) for power system stability enhancement. The combinatorial effect of generator nonlinearities and parameter uncertainties, unmodelled dynamics, wind speed randomness, is aggregated into a perturbation, which is rapidly estimated by a nonlinear extended state observer (ESO) in real-time. Then, the perturbation estimate is fully compensated by a robust passive controller to realize a globally consistent control performance, in which the energy of the closed-loop system is carefully reshaped through output feedback passification, such that a considerable system damping can be injected to improve the transient responses of DFIG in various operation conditions of power systems. Six case studies are carried out while simulation results verify that RPC can rapidly stabilize the disturbed DFIG system much faster with less overshoot, as well as supress power oscillations more effectively compared to that of linear proportional-integral-derivative (PID) control and nonlinear feedback linearization control (FLC).

22 February 2023 in Electronics
Verified
Journal Article
Open access
PDF file
YJYaoxi Jiang
Yaoxi Jiang
HSHongchun Shu
Hongchun Shu
MLMengli Liao
Mengli Liao
Modular multilevel converter (MMC) is a key device of high-voltage-direct circuit (HVDC) transmission system, the sub-module detection technology of which will directly influence the damage severity, and even the reliability of the whole system. In this paper, the open-circuit fault characteristics of an insulated gate bipolar transistor (IGBT) in a sub-module are analyzed, and a fault-tolerant optimal control strategy is proposed for the redundant hot-reserved MMC based on nearest-level modulation (NLM). A fault sub-module diagnosis and location strategy based on the deviation distance of the capacitor voltages is presented. After the faulty sub-module is removed, due to the asymmetric operation of the MMC, odd-order circulating currents are introduced in the faulty phase, in which the fundamental-frequency circulating current is the major component; the fundamental-frequency voltage related to the redundancy rate is injected into the faulty phase, which effectively suppresses the fundamental-frequency circulating current and harmonics in the faulty phase. The proposed method combines fault detection and fault ride-through steps, so it has the features of high reliability and high compatibility. Based on the Matlab/Simulink simulation model, the effectiveness of the proposed strategy is verified.

9 January 2020 in Energies
Verified
Journal Article
Open access
PDF file
HSHongchun Shu
Hongchun Shu
NANa An
Na An
Bo YangBo Yang
Bo Yang
YDYue Dai
Yue Dai
YGYu Guo
Yu Guo
The probability of a single pole-to-ground fault in high voltage direct current (HVDC) transmission lines is relatively high. For the modular multilevel converter HVDC (MMC-HVDC) systems, when a single pole-to-ground fault occurs, the fault current is small, and it is difficult to identify the fault quickly. Through a detailed analysis of the characteristics of the single pole-to-ground fault of the MMC-HVDC transmission line, it is found that the single pole-to-ground fault has obvious capacitance-related characteristics, and the transient process after the single pole-to-ground fault is the discharge process of the distributed capacitance of the line. However, other faults do not have such obvious capacitance-related characteristics. Based on such feature, this paper proposes a novel capacitive fuzzy identification method to identify the single pole-to-ground fault. This algorithm can effectively identify both the fault of single pole-to-ground and the fault pole, which can contribute to the large database of the future smart grid.

22 March 2020 in Energies
Verified
Journal Article
Open access
PDF file
HSHongchun Shu
Hongchun Shu
YHYiming Han
Yiming Han
RHRan Huang
Ran Huang
YTYutao Tang
Yutao Tang
PCPulin Cao
Pulin Cao
YZYu Zhang
Yu Zhang
Due to the complex structure of the T-connection transmission lines, it is extremely difficult to identify the reflected travelling wave from the fault point and that from the connection point by the measurement from only one terminal. According to the characteristics of the structure of the T-connection transmission line, the reflection of the travelling wave within the line after the failure of different sections in T-connection transmission line are analyzed. Based on the lattice diagram of the travelling wave, the sequence of travelling waves detected at the measuring terminal varies with the fault distance and the faulty section. Moreover, the sequence of travelling waves detected in one terminal is unique at each faulty section. This article calculates the arrival time of travelling waves of fault points at different locations in different sections to form the collection of the travelling wave arrival time sequence. Then the sequence of travelling waves of the new added fault waveforms is extracted to compare with the sequences in the collection for the faulty section identification and fault location. This proposed method can accurately locate the fault with different fault types, fault resistances and system impedances by only single-terminal fault data. Both Power Systems Computer Aided Design/ Electromagnetic Transients including DC (PSCAD/EMTDC) and actual measurement data are implemented to verify the effectiveness of this method.

15 June 2023 in Electronics
Verified
Journal Article
Open access
PDF file
YJYaoxi Jiang
Yaoxi Jiang
WWWentao Wang
Wentao Wang
HSHongchun Shu
Hongchun Shu
JZJunjie Zhang
Junjie Zhang
Significant circulating currents in the modular multilevel converter (MMC) increase system losses and complicate heat-sink design. Conventional PI and PR controllers can achieve steady-state error adjustment, but are sensitive to parameter changes and model uncertainty, heavily relying on coordinate transformations and careful design of model parameters. Model predictive control (MPC) has the characteristics of simple design, good robustness, and excellent dynamic response; however, it encountered the complexity of adjusting weighting factors. This paper proposed circulating the current model predictive proportional integral control (MPPIC) method in abc reference frame. This hybrid control solution utilized the predictive model and traditional PI algorithm to combine the advantages of nonlinear and linear control. Compared with existing suppression methods, this method avoided complex mathematical operations and a selection of weight coefficients, was easy to implement, and can effectively suppress circulating currents under different modulation ratios. Simulations were conducted on MATLAB/Simulink to verify the effectiveness of the proposed control strategy. MPPIC can not only distinctly suppress the circulating currents, but also reduce the overall voltage fluctuation of sub-modules capacitors under different modulation ratios, and had almost no any adverse effect on the performance of MMC.