Vipul R Sheth

Dr. Vipul R Sheth

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2011 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
VSVipul R Sheth
Vipul R Sheth
YLYuguo Li
Yuguo Li
LCLiu Qi Chen
Liu Qi Chen
CHChristine M. Howison
Christine M. Howison
CFChris A. Flask
Chris A. Flask
MPMark Pagel
Mark Pagel
Paramagnetic chemical exchange saturation transfer (PARACEST) MRI contrast agents have been developed that can measure pH in solution studies, but these agents have not previously been detected in vivo. To use the PARACEST agent Yb‐DO3A‐oAA to measure the extracellular pH (pHe) in tumor tissue, a chemical exchange saturation transfer fast imaging with steady state precession MRI protocol was developed, the saturation period was optimized for sensitive chemical exchange saturation transfer (CEST) detection, and median filtering was used to remove artifacts in CEST spectra. These improvements were used to correlate pH with a ratio of two CEST effects of Yb‐DO3A‐oAA at a 7 T magnetic field strength (R2 = 0.99, standard deviation of precision = 0.011 pH units). The PARACEST agent could not be detected in tumor tissue following i.v. injection due to the low sensitivity of in vivo CEST MRI. Yb‐DO3A‐oAA was detected in tumor tissue and leg muscle after directly injecting the PARACEST agent into these tissues. The measured CEST effects were used to measure a tumor pH of 6.82 ± 0.21 and a leg muscle pH of 7.26 ± 0.14, and parametric pH maps were also generated from these tissue regions. These results demonstrated that tumor pHe can be measured with a PARACEST agent and a rapid CEST‐MRI protocol. Magn Reson Med, 2012.

1 August 2016 in NeuroImage
Verified
Journal Article
Closed access
VSVipul R Sheth
Vipul R Sheth
HSHongda Shao
Hongda Shao
JCJun Chen
Jun Chen
SVScott Vandenberg
Scott Vandenberg
JCJody Corey-Bloom
Jody Corey-Bloom
Jiang DuJiang Du
Jiang Du

1 January 2012 in Molecular Imaging
Verified
Journal Article
Open access
GLGuanshu Liu
Guanshu Liu
YLYuguo Li
Yuguo Li
VSVipul R Sheth
Vipul R Sheth
MPMark Pagel
Mark Pagel
The measurement of extracellular pH (pHe) has potential utility for cancer diagnoses and for assessing the therapeutic effects of pH-dependent therapies. A single magnetic resonance imaging (MRI) contrast agent that is detected through paramagnetic chemical exchange saturation transfer (PARACEST) was designed to measure tumor pHe throughout the range of physiologic pH and with magnetic resonance saturation powers that are not harmful to a mouse model of cancer. The chemical characterization and modeling of the contrast agent Yb3+-1,4,7,10-tetraazacyclododecane-1,4,7-triacetic acid, 10-o-aminoanilide (Yb-DO3A-oAA) suggested that the aryl amine of the agent forms an intramolecular hydrogen bond with a proximal carboxylate ligand, which was essential for generating a practical chemical exchange saturation transfer (CEST) effect from an amine. A ratio of CEST effects from the aryl amine and amide was linearly correlated with pH throughout the physiologic pH range. The pH calibration was used to produce a parametric pH map of a subcutaneous flank tumor on a mouse model of MCF-7 mammary carcinoma. Although refinements in the in vivo CEST MRI methodology may improve the accuracy of pHe measurements, this study demonstrated that the PARACEST contrast agent can be used to generate parametric pH maps of in vivo tumors with saturation power levels that are not harmful to a mouse model of cancer.

30 November 2010 in Contrast Media & Molecular Imaging
Verified
Journal Article
Open access
PDF file
YLYuguo Li
Yuguo Li
VSVipul R Sheth
Vipul R Sheth
Guanshu LiuGuanshu Liu
Guanshu Liu
MPMark Pagel
Mark Pagel
The CEST effect of many PARACEST MRI contrast agents changes in response to a molecular biomarker. However, other molecular biomarkers or environmental factors can influence CEST, so that a change in CEST is not conclusive proof for detecting the biomarker. To overcome this problem, a second control CEST effect may be included in the same PARACEST agent, which is responsive to all factors that alter the first CEST effect except for the biomarker to be measured. To investigate this approach, a PARACEST MRI contrast agent was developed with one CEST effect that is responsive to esterase enzyme activity and a second control CEST effect. The ratio of the two CEST effects was independent of concentration and T1 relaxation, so that this agent was self‐calibrating with respect to these factors. This ratiometric method was dependent on temperature and was influenced by MR coalescence as the chemical exchange rates approached the chemical shifts of the exchangable protons as temperature was increased. The two CEST effects also showed evidence of having different pH dependencies, so that this agent was not self‐calibrating with respect to pH. Therefore, a self‐calibrating PARACEST MRI contrast agent can more accurately detect a molecular biomarker such as esterase enzyme activity, as long as temperature and pH are within an acceptable physiological range and remain constant. Copyright © 2010 John Wiley & Sons, Ltd.

1 January 2012 in Contrast Media & Molecular Imaging
Verified
Journal Article
Open access
PDF file
VSVipul R Sheth
Vipul R Sheth
Guanshu LiuGuanshu Liu
Guanshu Liu
YLYuguo Li
Yuguo Li
MPMark Pagel
Mark Pagel
The measurement of extracellular pH has potential utility for assessing the therapeutic effects of pH‐dependent and pH‐altering therapies. A PARAmagnetic chemical exchange saturation transfer (PARACEST) MRI contrast agent, Yb–DO3A–oAA, has two CEST effects that are dependent on pH. A ratio derived from these CEST effects was linearly correlated with pH throughout the physiological pH range. The pH can be measured with a precision of 0.21 pH units and an accuracy of 0.09 pH units. The pH measurement is independent of concentration and T1 relaxation times, but is dependent on temperature. Although MR coalescence affects the CEST measurements, especially at high pH, the ratiometric analysis of the CEST effects can account for incomplete saturation of the agent's amide and amine that results from MR coalescence. Provided that an empirical calibration is determined with saturation conditions, magnetic field strength and temperature that can be used for subsequent studies, these results demonstrate that this single PARACEST MRI contrast agent can accurately measure pH. Copyright © 2012 John Wiley & Sons, Ltd.

5 August 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Jiang DuJiang Du
Jiang Du
VSVipul R Sheth
Vipul R Sheth
QHQun He
Qun He
MCMichael Carl
Michael Carl
JCJun Chen
Jun Chen
GBGraeme M. Bydder
Graeme M. Bydder
Recent research demonstrates that white matter of the brain contains not only long T2 components, but a minority of ultrashort T2* components. Adiabatic inversion recovery prepared dual echo ultrashort echo time (IR-dUTE) sequences can be used to selectively image the ultrashort T2* components in white matter of the brain using a clinical whole body scanner. The T2*s of the ultrashort T2* components can be quantified using mono-exponential decay fitting of the IR-dUTE signal at a series of different TEs. However, accurate T1 measurement of the ultrashort T2* components is technically challenging. Efficient suppression of the signal from the majority of long T2 components is essential for robust T1 measurement. In this paper we describe a novel approach to this problem based on the use of IR-dUTE data acquisitions with different TR and TI combinations to selectively detect the signal recovery of the ultrashort T2* components. Exponential recovery curve fitting provides efficient T1 estimation, with minimized contamination from the majority of long T2 components. A rubber phantom and a piece of bovine cortical bone were used for validation of this approach. Six healthy volunteers were studied. An averaged T2* of 0.32±0.09 ms, and a short mean T1 of 226±46 ms were demonstrated for the healthy volunteers at 3T.