Cold ironing refers to the usage of less polluting power supply sources to deliver electricity to the moored ship. Such a shore-to-ship system is used when the ship is at a port so the auxiliary combustion engines may be turned off. This paper presents the numerical simulation results of a medium voltage cold-ironing system with regard to the currents flowing between the ship’s hull and grounding busbar. The IT electrical inland system with a neutral grounding resistor, as commonly used in shore-to-ship systems, is investigated. Parasitic capacitances present between the phase-to-hull and phase-to-ground in real-world applications can vary from each other. The direct and alternating currents flowing across the hull, seawater and the pier structure are amongst the causes that can lead to premature reinforced concrete degradation. Chosen cases of phase-to-ground or hull unequal capacitances influencing AC stray currents were considered.
20 February 2020 in Journal of Marine Engineering & Technology
The article describes research into the use of acoustic emission elastic waves (AE) for diagnosing insulated-gated bipolar transistors (IGBTs). Currently used in many modern shipboard power electronic systems, IGBTs are crucial components required to operate with extreme reliability. The acoustic emission elastic waves method was used to determine the acoustic signals of switching transistor and can be used to monitor early stages of damage. Transistor diagnostics makes use of selected frequency descriptors of AE and appropriate signal analysis.
The paper covers the theoretical background as well as chosen selected experimental results obtained for two AC current generators connected to voltage source inverters working in parallel. Inverters were connected in parallel via their intermediate direct current circuits by means of auctioneering diodes which select higher voltage source, and then directly to a DC power network. Selected real time control algorithm for a digital signal processor (DSP) and a field programmable gate array (FPGA) was used to achieve the proper excitation of two different types of alternators: a squirrel-cage generator denoted as (SCG) and a self excited synchronous generator (SESG). Another task for the excitation system was to maintain the proper level of direct current link voltage and stable power distribution between both generators rotating at changing speeds. The windings of alternators were fed with the use of so-called machine side inverters. The asynchronous generator was a voltage source inverter driven with the use of a sensorless multiscalar algorithm based on the current machine model, whereas the self excited synchronous generator worked on the field oriented control principle. To prove the robustness of the chosen algorithm, different types of load were applied while during the parallel work of the generators and inverters.
Modern seagoing ships are often equipped with converters which utilize semiconductor power electronics devices like thyristors or power transistors. Most of them are used in driving applications such as powerful main propulsion plants, auxiliary podded drives and thrusters. When it comes to main propulsion drives the power gets seriously high, thus the need for use of medium voltage power electronics devices arises. As it turns out, power electronic parts are the most susceptible to faults or failures in the whole electric drive system. These devices require efficient cooling, so manufacturers design housings in a way that best dissipates heat from the inside of the chips to the metal housing. This results in susceptibility to damage due to the heterogeneity of combined materials and the difference in temperature expansion of elements inside the power device. Currently used methods of prediction of damage and wear of semiconductor elements are limited to measurements of electrical quantities generated by devices during operation and not quite effective in case of early-stage damage to semiconductor layers. The article presents an introduction and preliminary tests of a method utilizing an acoustic emission sensor which can be used in detecting early stage damages of the gate turn-off thyristor. Theoretical considerations and chosen experimental results of initial measurements of acoustic emission signals of the medium voltage gate turn-off thyristor are presented.
This work is an introduction of acoustic emission (AE) signals used in order to detect the malfunction of selected semiconductor elements. The authors proposed the use of internally generated signals (elastic waves) of acoustic emission leading to the detection of the pre-fail state of switching IGBT transistors. The analysis of the AE signals allows the creation of a reference pattern of properly working transistors and at the same time the identification of abnormal signals, which are generated by a defective element. Unlike many papers, this article shows experimental results demonstrating a comparison of undamaged, properly working and defective IGBT transistors which can be used, for example, as a reference for diagnostic tools. Analysis of the signal in the frequency domain obtained from the faulty transistor (overheated or with damaged casing) shows the presence of additional frequencies which can indicate the imminent occurrence of critical damage.
The development of modern measurement methods for ship systems has occurred due to economic changes and increasingly stringent environmental requirements