Samuel Usherovich

Mr. Samuel Usherovich


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2024 in Electronics
Verified
Journal Article
Open access
PDF file
CPCrystal Penner
Crystal Penner
SUSamuel Usherovich
Samuel Usherovich
SASophia Andru
Sophia Andru
CBCamille Bélanger-Champagne
Camille Bélanger-Champagne
CDCheryl Duzenli
Cheryl Duzenli
CHCornelia Hoehr
Cornelia Hoehr
As the technology to deliver precise and very high radiotherapeutic doses with narrow margins grows to better serve patients with complex radiotherapeutic needs, so does the need for sensors and sensor systems that can reliably deliver multi-point dose monitoring and dosimetry for enhanced safety and access. To address this need, we investigated a novel five-point scintillator system for simultaneously sampling points across a 74 MeV proton beam with a Hamamatsu 16-channel MPPC array. We studied the response across beam widths from 25 mm down to 5 mm in diameter and in multiple depths to observe beam penumbrae and output factors as well as depth–dose. We found through comparison to ionization chambers and radiochromic film that the array is capable of measurements accurate to within 8% in the centre of proton beams from 5 to 25 mm in diameter, and within 2% at 3.5 cm depth in water. The results from three trials are repeatable after calibration to within <1%. Overall, the five optical fibre sensor system shows promise as a fast, multipoint relative dosimetry system.

20 December 2022 in Electronics
Verified
Journal Article
Open access
PDF file
CPCrystal Penner
Crystal Penner
SUSamuel Usherovich
Samuel Usherovich
JNJana Niedermeier
Jana Niedermeier
CBCamille Bélanger-Champagne
Camille Bélanger-Champagne
MTMichael Trinczek
Michael Trinczek
CHCornelia Hoehr
Cornelia Hoehr
In proton therapy, the dose from secondary neutrons to the patient can contribute to side effects and the creation of secondary cancer. A simple and fast detection system to distinguish between dose from protons and neutrons both in pretreatment verification as well as potentially in vivo monitoring is needed to minimize dose from secondary neutrons. Two 3 mm long, 1 mm diameter organic scintillators were tested for candidacy to be used in a proton–neutron discrimination detector. The SCSF-3HF (1500) scintillating fibre (Kuraray Co. Chiyoda-ku, Tokyo, Japan) and EJ-260 plastic scintillator (Eljen Technology, Sweetwater, TX, USA) were irradiated at the TRIUMF Neutron Facility and the Proton Therapy Research Centre. In the proton beam, we compared the raw Bragg peak and spread-out Bragg peak response to the industry standard Markus chamber detector. Both scintillator sensors exhibited quenching at high LET in the Bragg peak, presenting a peak-to-entrance ratio of 2.59 for the EJ-260 and 2.63 for the SCSF-3HF fibre, compared to 3.70 for the Markus chamber. The SCSF-3HF sensor demonstrated 1.3 times the sensitivity to protons and 3 times the sensitivity to neutrons as compared to the EJ-260 sensor. Combined with our equations relating neutron and proton contributions to dose during proton irradiations, and the application of Birks’ quenching correction, these fibres provide valid candidates for inexpensive and replicable proton-neutron discrimination detectors.

8 January 2023 in Electronics
Verified
Journal Article
Open access
PDF file
JNJana Niedermeier
Jana Niedermeier
CPCrystal Penner
Crystal Penner
SUSamuel Usherovich
Samuel Usherovich
CBCamille Bélanger-Champagne
Camille Bélanger-Champagne
EPElisabeth Paulssen
Elisabeth Paulssen
CHCornelia Hoehr
Cornelia Hoehr
In recent years, proton therapy has gained importance as a cancer treatment modality due to its conformality with the tumor and the sparing of healthy tissue. However, in the interaction of the protons with the beam line elements and patient tissues, potentially harmful secondary neutrons are always generated. To ensure that this neutron dose is as low as possible, treatment plans could be created to also account for and minimize the neutron dose. To monitor such a treatment plan, a compact, easy to use, and inexpensive dosimeter must be developed that not only measures the physical dose, but which can also distinguish between proton and neutron contributions. To that end, plastic optical fibers with scintillation materials (Gd2O2S:Tb, Gd2O2S:Eu, and YVO4:Eu) were irradiated with protons and neutrons. It was confirmed that sensors with different scintillation materials have different sensitivities to protons and neutrons. A combination of these three scintillators can be used to build a detector array to create a biological dosimeter.

6 June 2024 in Electronics
Verified
Journal Article
Open access
PDF file
CPCrystal Penner
Crystal Penner
SUSamuel Usherovich
Samuel Usherovich
SASophia Andru
Sophia Andru
CBCamille Bélanger-Champagne
Camille Bélanger-Champagne
JHJanina Hohnholz
Janina Hohnholz
CHCornelia Hoehr
Cornelia Hoehr
Optical fibres are gaining popularity for relative dosimetry in proton therapy due to their spatial resolution and ability for near real-time acquisition. For FLASH proton therapy, these fibres need to handle higher dose rates and larger doses than for conventional proton dose rates. We developed a multi-point fibre sensor embedded in a 3D-printed phantom which can measure the profile of a FLASH proton beam. Seven PMMA fibres of 1 mm diameter were embedded in a custom 3D-printed plastic phantom of the same density as the fibres. The phantom was placed in a proton beam with FLASH dose rates at the TRIUMF Proton Therapy Research Centre (PTRC). The sensor was exposed to different proton energies, 13.5 MeV, 19 MeV and 40.4 MeV, achieved by adding PMMA bolus in front of the phantom and three different beam currents, varying the dose rates from 7.5 to 101 Gy/s. The array was able to record beam profiles in both transverse and axial directions in relative agreement with measurements from EBT-XD radiochromic films (transverse) and Monte Carlo simulations (axial). A decrease in light output over time was observed, which might be caused by radiation damage in the matrix of the fibre and characterised by an exponential decay function.