6 December 2017 in IEEE Sensors Journal
Verified
Journal Article
Closed access
CPCrystal Penner
Crystal Penner
CHCornelia Hoehr
Cornelia Hoehr
SOSinead O'Keeffe
Sinead O'Keeffe
PWPeter Woulfe
Peter Woulfe
CDCheryl Duzenli
Cheryl Duzenli
A characterization study was carried out to determine if a novel, millimeter sized Terbium-activated Gadolinium Oxysulfide optical fibre detector has potential for future use in proton dosimetry. Preliminary studies employed a Theratronics Theratron 780C Cobalt-60 unit and were used to determine nominal dose response, field size response and Čerenkov contributions in 1.25-MeV gamma radiation. More extensive testing was done using 74 MeV-protons produced in the TRIUMF 500-MeV cyclotron facility examining raw Bragg peak, spread out Bragg peak, dose response, and Čerenkov signal. The detector was low-cost and easily assembled; it showed excellent sensitivity, signal to noise ratio, and reproducibility. Quenching at high linear energy transfer was severe. Additional investigations are needed to further explore Čerenkov-only depth-dose curves, signal detection at the extreme distal end of the Bragg peak, and possible sensitivity to neutrons.

29 June 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CHCornelia Hoehr
Cornelia Hoehr
MHMatthew Hanna
Matthew Hanna
SZStefan Zeisler
Stefan Zeisler
CPCrystal Penner
Crystal Penner
MSMatthew Stokely
Matthew Stokely
MDMorgan Dehnel
Morgan Dehnel
Many medical isotopes can be produced on a small cyclotron. The alignment and profiles of low-energy proton beams from cyclotrons used for medical radioisotope production, such as the TR13 cyclotron at TRIUMF, Canada, cannot be directly quantified during dose delivery with simultaneous constant feedback and sharp spatial resolutions. Doped silica fibers are a potential solution that has been tested at TRIUMF. To measure the effects of irradiation inside an isotope production target, we attached fibers to the outside of an 18O gas target and measured the light output during irradiation. Different dopants, fiber diameters, and target materials were investigated. It was found that 200 µm diameter Ce- and B-doped fibers produce signals linearly proportional to the beam current. This only deviated when the target was moved such that the beam was steered into the target wall, increasing the production of prompt radiation and causing the beam current to decrease but the fiber signal to increase. With the technique described here, the beam can be monitored on the target, including its steering and its overall alignment with the target.

19 March 2024 in Electronics
Verified
Journal Article
Open access
PDF file
CPCrystal Penner
Crystal Penner
SUSamuel Usherovich
Samuel Usherovich
SASophia Andru
Sophia Andru
CBCamille Bélanger-Champagne
Camille Bélanger-Champagne
CDCheryl Duzenli
Cheryl Duzenli
CHCornelia Hoehr
Cornelia Hoehr
As the technology to deliver precise and very high radiotherapeutic doses with narrow margins grows to better serve patients with complex radiotherapeutic needs, so does the need for sensors and sensor systems that can reliably deliver multi-point dose monitoring and dosimetry for enhanced safety and access. To address this need, we investigated a novel five-point scintillator system for simultaneously sampling points across a 74 MeV proton beam with a Hamamatsu 16-channel MPPC array. We studied the response across beam widths from 25 mm down to 5 mm in diameter and in multiple depths to observe beam penumbrae and output factors as well as depth–dose. We found through comparison to ionization chambers and radiochromic film that the array is capable of measurements accurate to within 8% in the centre of proton beams from 5 to 25 mm in diameter, and within 2% at 3.5 cm depth in water. The results from three trials are repeatable after calibration to within <1%. Overall, the five optical fibre sensor system shows promise as a fast, multipoint relative dosimetry system.

8 February 2023 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
CBCamille Bélanger-Champagne
Camille Bélanger-Champagne
FFFiammetta Fricano
Fiammetta Fricano
AMAdriana Morana
Adriana Morana
DLDamien Lambert
Damien Lambert
CPCrystal Penner
Crystal Penner
CHCornelia Hoehr
Cornelia Hoehr
We investigated the radiation-induced luminescence of 62.5 μm, 10 μm and 3 μm germanosilicate single- and multi-mode telecom-grade optical fibers for use as high-resolution dosimeters at dose rates ranging between 5 Gy s -1 and 120 Gy s -1 using proton beams of varying currents and energies. Only one of the two single-mode fibers under investigation had a detectable light yield, with a dose rate threshold around 20 Gy s -1 . All tested multi-mode fibers showed a detectable response over the whole accessible dose rate range. All tested multi-mode fibers displayed a linear dose rate response when the proton beam energy was fixed. However, the slope of the response curve showed a strong dependence on the proton beam energy. Geometry and material differences, as well as radiation-induced attenuation effects have been ruled out as sources for the observed proton energy dependence of the dose rate response.

30 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
OOOlugbenga Olusoji
Olugbenga Olusoji
CPCrystal Penner
Crystal Penner
CBCamille Bélanger-Champagne
Camille Bélanger-Champagne
WKWern Kam
Wern Kam
Michael MartynMichael Martyn
Michael Martyn
SOSinead O'Keeffe
Sinead O'Keeffe
Phosphorous-doped silica optical fibres with a core diameter of 4 µm were tested in X-ray and proton fields for application in cancer therapy dosimetry. Specifically, the radiation-induced attenuation was investigated in terms of linearity in deposited dose in 15 MV and 6 MV photons and 74 MeV protons, as well as Bragg-peak detection along the proton track. Fibres were found to demonstrate linear relative dose response in both radiation modalities, but possible saturation did occur at the high linear energy transfer of the Bragg peak. This demonstrates the possibility to use these fibres as a relative dosimeter for radiation therapy applications.

20 December 2022 in Electronics
Verified
Journal Article
Open access
PDF file
CPCrystal Penner
Crystal Penner
SUSamuel Usherovich
Samuel Usherovich
JNJana Niedermeier
Jana Niedermeier
CBCamille Bélanger-Champagne
Camille Bélanger-Champagne
MTMichael Trinczek
Michael Trinczek
CHCornelia Hoehr
Cornelia Hoehr
In proton therapy, the dose from secondary neutrons to the patient can contribute to side effects and the creation of secondary cancer. A simple and fast detection system to distinguish between dose from protons and neutrons both in pretreatment verification as well as potentially in vivo monitoring is needed to minimize dose from secondary neutrons. Two 3 mm long, 1 mm diameter organic scintillators were tested for candidacy to be used in a proton–neutron discrimination detector. The SCSF-3HF (1500) scintillating fibre (Kuraray Co. Chiyoda-ku, Tokyo, Japan) and EJ-260 plastic scintillator (Eljen Technology, Sweetwater, TX, USA) were irradiated at the TRIUMF Neutron Facility and the Proton Therapy Research Centre. In the proton beam, we compared the raw Bragg peak and spread-out Bragg peak response to the industry standard Markus chamber detector. Both scintillator sensors exhibited quenching at high LET in the Bragg peak, presenting a peak-to-entrance ratio of 2.59 for the EJ-260 and 2.63 for the SCSF-3HF fibre, compared to 3.70 for the Markus chamber. The SCSF-3HF sensor demonstrated 1.3 times the sensitivity to protons and 3 times the sensitivity to neutrons as compared to the EJ-260 sensor. Combined with our equations relating neutron and proton contributions to dose during proton irradiations, and the application of Birks’ quenching correction, these fibres provide valid candidates for inexpensive and replicable proton-neutron discrimination detectors.