As photovoltaic (PV) generation has been one of the major renewable energy sources around the world, its PV capacity has also increased. When the large-scale PV systems are integrated into the distribution network, the complexity of the assessment process of the distribution network reliability will increase hazardously. In order to accurately assess this reliability in the distribution network combined with the PV generation, a reliability assessment procedure is proposed. In order to accurately evaluate the impact of the failure of conventional power equipment on reliability, the time-varying failure rate of conventional power equipment is modeled, taking into account the aging period. Then, in order to accurately evaluate the reliability improvement with PV systems integration, the new procedure is proposed highlighting the following contributions: 1) five new indices are added. 2) the PV output is modeled so that not only the radiation intensity but also the failure and degradation of PV modules are represented. 3) the time-varying islanding operation is considered and integrated. A case study using real-life distribution network topology and data in China is applied to verify that the newly proposed reliability indices display more sensitivity, and the proposed procedure significantly improves the accuracy of the reliability assessment.
12 March 2018 in IET Generation, Transmission & Distribution
The node voltage profile is more likely to be violated as the electric vehicles (EVs) charging load spreads in distribution network. Due to the stochastic nature of EV charging load spatially, more flexible reactive power compensation in different locations becomes important. However, the conventional reactive power compensation equipment has no flexibility spatially. Therefore, two kinds of reactive power compensation strategies using EVs considering drivers’ reasons are proposed. Drivers’ reasons contain charging demand, charging opportunity loss (time) and profit. In Strategy 1, EV chargers are used to fully compensate reactive power after finishing the unregulated charging. Thus, drivers’ charging behaviour is not influenced at all. In Strategy 2, the operating power factors of EV chargers are treated as variables for the optimisation. The constraint of operating power factors is derived from analysing the charging demand and the charging opportunity loss (time) for drivers. Then, in order to motivate drivers, an incentive method is introduced based on the quantification of each driver's contribution to the voltage. The case study shows that Strategy 1 performs well at nodes having the non‐significant voltage deviation without any constraint on driver's charging behaviour, while Strategy 2 performs well at nodes where the voltages deviation is significant.
26 July 2021 in IEEE Transactions on Power Systems
In this paper, a novel energy flow analysis (EFA) is proposed based on the signal reconstruction and decomposition to investigate the electromechanical oscillations. In contrast to the conventional EFA, the connection between the proposed EFA and modal analysis (MA) can be quantitatively revealed for arbitrary models of synchronous generators in multi-machine power systems. Firstly, the time-domain implementation (TDI) of the proposed EFA is designed. Specifically, the measurements at the terminal of a local generator are reconstructed through an exponential operator and then decomposed with respect to an angular frequency. Then, the mode-screened damping torque coefficient is defined to extract the damping feature with respect to an electromechanical oscillation mode. After that, the frequency-domain implementation (FDI) is derived. Specifically, the Parseval's Theorem is applied to transform the proposed EFA from the time domain to frequency domain. On this basis, the consistency between the proposed EFA and MA is strictly proved, which is applicable for arbitrary models of synchronous generators in multi-machine power systems. Additionally, the application procedure of the proposed EFA in investigating electromechanical oscillations is given. Finally, the proposed EFA are substantially demonstrated in multiple case studies.
Electric vehicles (EV) and photovoltaic (PV) generation are widely recognized around the world. Most EV owners in the major Chinese cities are forced to charge their EV batteries at the workplace during the daytime due to the limited space near their homes, which will increase the peak load during the daytime. On the other hand, the PV output is most likely to have a peak at around noon, which means, PVs could have a potential capability to compensate the EV charging load. An EV owner-friendly charging strategy based on PV utilization which alleviates both the EV charging constraints and the negative impact of the EV charging load on the grid is proposed. The PV utilization for compensating the unconstrained EV charging load is maximized to derive the maximum number of EVs with unconstrained charging. If the actual number of EVs exceeds the maximum number, a portion of EVs have to be charged only from the grid. Then, the line loss is introduced as the optimization objective in which the charging states are regulated. The case study shows that the proposed strategy can successfully increase the number of EVs with unconstrained charging, and reduce the peak-to-peak of the load curve.
The machine‐side oscillation (MSO) of the full converter‐based wind generation (FCWG) systems is a critical threat to the reliable wind power supply. The introduction of the auxiliary resonance controller (ARC) to the machine‐side converter (MSC) controls of FCWG can effectively improve the converter‐driven stability of the power grid, but it would also complicate MSOs of FCWG. Thus, it is of great significance to study the damping feature of MSOs of FCWG. In this paper, the energy flow analysis (EFA) is applied to quantitatively investigate MSOs of FCWG. Firstly, the configuration and machine‐side control loops of FCWG are briefly introduced. Then, a mode screening‐based EFA is proposed for evaluating the damping feature of MSOs of FCWG in the time domain by applying the principle of the Laplace transform. After that, the eigenvalue analysis is conducted for MSOs of FCWG in the frequency domain to lay a foundation for revealing the essence of EFA. On this basis, the consistency of EFA with the eigenvalue analysis is strictly proved based on the Parseval's Theorem, which is applicable for arbitrary control schemes of FCWG. Finally, the proposed EFA is applied in numerically investigating multiple types of MSOs of FCWG in case studies.