Olga Krafcsik

Dr. Olga Krafcsik

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 August 2022 in Heliyon
Verified
Journal Article
Open access
AMAttila Mühl
Attila Mühl
PSPéter Szabó
Péter Szabó
OKOlga Krafcsik
Olga Krafcsik
ZAZoltán Aigner
Zoltán Aigner
JKJudit Kopniczky
Judit Kopniczky
Kinga TurzóKinga Turzó
Kinga Turzó
Soft tissue integration of dental implants lags behind natural biological integration of teeth mainly because of non-optimal surface features. Peri-implant infections resulting in loss of supporting bone jeopardize the success of implants. Our aim was to compare an anodized surface design with a turned one for a more optimal surface. Morphological and chemical structures of turned and anodized Ti surfaces (grade 5: Ti6Al4V) discs were examined by scanning electron microscopy (SEM-EDS), energy dispersive X-ray spectroscopy (EDS), and atomic force microscopy (AFM). The hydrophilic or hydrophobic features of the surfaces were determined by dynamic contact angle measurement. SEM and AFM revealed significant differences in the morphology and roughness (Ra) of the samples. Anodized discs presented a granular structure, while turned ones had circular grooves. The roughness was significantly higher for the anodized samples compared to the turned ones. XPS and EDS confirmed typical elements for both Ti6Al4V samples. Due to anodization, the amount of Ti (IV) had increased and Ti (III) had decreased in the thicker oxide layer. Anodized samples resulted in a more hydrophilic surface than the turned ones. The results suggest that the tested anodized samples present optimal surface characteristics to be used as abutment material for an optimal soft tissue integration.

1 July 2004 in Applied Surface Science
Verified
Journal Article
Closed access
ZHZs.J Horváth
Zs.J Horváth
LDL Dózsa
L Dózsa
OKOlga Krafcsik
Olga Krafcsik
TMT Mohácsy
T Mohácsy
GVGy Vida
Gy Vida

27 June 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
SCSzabolcs Czene
Szabolcs Czene
NJNikoletta Jegenyes
Nikoletta Jegenyes
OKOlga Krafcsik
Olga Krafcsik
SLSándor Lenk
Sándor Lenk
Zsolt CziganyZsolt Czigany
Zsolt Czigany
ÁGÁdám Gali
Ádám Gali
Silicon carbide nanoparticles (SiC NPs) are promising inorganic molecular-sized fluorescent biomarkers. It is imperative to develop methods to functionalize SiC NPs for certain biological applications. One possible route is to form amino groups on the surface, which can be readily used to attach target biomolecules. Here, we report direct amino-termination of aqueous SiC NPs. We demonstrate the applicability of the amino-terminated SiC NPs by attaching bovine serum albumin as a model for functionalization. We monitor the optical properties of the SiC NPs in this process and find that the fluorescence intensity is very sensitive to surface termination. Our finding may have implications for a few nanometers sized SiC NPs containing paramagnetic color centers with optically read electron spins.

24 April 2024 in Polymers
Verified
Journal Article
Open access
PDF file
BJBertalan Jillek
Bertalan Jillek
PSPéter Szabó
Péter Szabó
JKJudit Kopniczky
Judit Kopniczky
OKOlga Krafcsik
Olga Krafcsik
ISIstván Szabó
István Szabó
Kinga TurzóKinga Turzó
Kinga Turzó
The goal of the study was to compare the surface characteristics of typical implant materials used in orthopedic surgery and traumatology, as these determine their successful biointegration. The morphological and chemical structure of Vortex plate anodized titanium from commercially pure (CP) Grade 2 Titanium (Ti2) is generally used in the following; non-cemented total hip replacement (THR) stem and cup Ti alloy (Ti6Al4V) with titanium plasma spray (TPS) coating; cemented THR stem Stainless steel (SS); total knee replacement (TKR) femoral component CoCrMo alloy (CoCr); cemented acetabular component from highly cross-linked ultrahigh molecular weight polyethylene (HXL); and cementless acetabular liner from ultrahigh molecular weight polyethylene (UHMWPE) (Sanatmetal, Ltd., Eger, Hungary) discs, all of which were examined. Visualization and elemental analysis were carried out by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and X-ray photoelectron spectroscopy (XPS). Surface roughness was determined by atomic force microscopy (AFM) and profilometry. TPS Ti presented the highest Ra value (25 ± 2 μm), followed by CoCr (535 ± 19 nm), Ti2 (227 ± 15 nm) and SS (170 ± 11 nm). The roughness measured in the HXL and UHMWPE surfaces was in the same range, 147 ± 13 nm and 144 ± 15 nm, respectively. EDS confirmed typical elements regarding the investigated prosthesis materials. XPS results supported the EDS results and revealed a high % of Ti4+ on Ti2 and TPS surfaces. The results indicate that the surfaces of prosthesis materials have significantly different features, and a detailed characterization is needed to successfully apply them in orthopedic surgery and traumatology.

28 May 2025 in Colloids and Surfaces A: Physicochemical and Engineering Aspects
Verified
Journal Article
Open access
EKEtelka Kiss
Etelka Kiss
ABAnna Bulátkó
Anna Bulátkó
JKJózsef Kozma
József Kozma
OKOlga Krafcsik
Olga Krafcsik
MKMiklós Kubinyi
Miklós Kubinyi
KLKrisztina László
Krisztina László