Juan Zhao

Dr. Juan Zhao


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2018 in Energies
Verified
Journal Article
Open access
PDF file
JZJuan Zhao
Juan Zhao
YJyasheng ji
yasheng ji
Yanping YuanYanping Yuan
Yanping Yuan
ZZZhaoli Zhang
Zhaoli Zhang
JLJun Lu
Jun Lu
A solar heating system (SHS) with a phase change material (PCM) thermal storage tank is proposed with the view that traditional heat water storage tanks present several problems including large space requirements, significant heat loss and unstable system performance. An entire heating season (November–March) is selected as the research period on the basis of numerical models of the SHS-PCM. In addition, taking a public building in Lhasa as the object, the heating conditions, contribution rate of solar energy, and overall energy-saving capability provided by the heating system are analyzed under different PCM storage tanks and different terminal forms. The results show that an SHS with a PCM tank provides a 34% increase in energy saving capability compared to an ordinary water tank heating system. It is suggested that the design selection parameters of the PCM storage tank should specify a daily heat storage capacity that satisfies 70~80% of the entire heating season. A floor radiant system with supply/return water temperatures of 40/35 °C provides the optimal operation and the largest energy saving capability.

14 December 2017 in Energies
Verified
Journal Article
Open access
PDF file
JZJuan Zhao
Juan Zhao
YJyasheng ji
yasheng ji
Yanping YuanYanping Yuan
Yanping Yuan
ZZZhaoli Zhang
Zhaoli Zhang
JLJun Lu
Jun Lu
A physical model and dynamic simulation models of a solar phase-change heat storage heating system with a plate solar collector, phase-change material (PCM) storage tank, plate heat exchanger, and auxiliary heat sources were established. A control strategy and numerical models for each of seven different operation modes that cover the entire heating season of the system were developed for the first time. The seven proposed operation modes are Mode 1: free cooling; Mode 2: reservation of heat absorbed by the solar collector in the PCM storage tank when there is no heating demand; Mode 3: direct supply of the heating demand by the solar collector; Mode 4: use of the heat absorbed by the solar collector to meet the heating demands, with the excess heat stored in the PCM storage tank; Mode 5: use of heat stored in the PCM storage tank to meet the heating demands, Mode 6: combined use of heat stored in the PCM storage tank and the auxiliary heating sources to meet the heating demands; and Mode 7: exclusive use of the auxiliary heat sources in order to meet the heating demands. Mathematical models were established for each of the above seven operation modes, taking into consideration the effects of the outdoor meteorological parameters and terminal load on the heating system. The real-time parameters for the entire heating season of the system with respect to the different operation modes can be obtained by solving the simulation models, and used as reference for the optimal design and operation of the actual system.

30 May 2022 in Energies
Verified
Journal Article
Open access
PDF file
JZJuan Zhao
Juan Zhao
GJGao Junmei
Gao Junmei
JLJunhui Liao
Junhui Liao
ZTZhou Bo Tao
Zhou Bo Tao
YBYifei Bai
Yifei Bai
TQTianwei Qiang
Tianwei Qiang
Solar heating technology has the advantages of being high efficiency, energy-saving, and environment protecting; however, the instability of solar energy and its mismatch with the variation characteristics of building heat load have caused great difficulties in the design and the efficient operation strategy of a solar system. A heat storage tank is an important part of a solar hot water system. In order to improve system efficiency, this paper proposes a flat plate PCM storage tank, establishes a mathematical model, and conducts experimental verification under different working conditions. Experiments show that in the heat storage process, the phase change material (PCM) only accounts for less than 20% of the space of the PCM storage tank, and its heat storage can reach 50% of the total heat storage of the tank. In the discharge process, the water temperature of the ordinary tank decreases by 20 °C within 1.5 h, and the phase change process lasts approximately 3 h, with the water temperature remaining at 45~50 °C during this period. In the natural cooling process, the heat discharge of the two water tanks at night was similar, while the temperature of the ordinary water tank decreased by 12 °C and that of the phase change water tank decreased by 7 °C. By simulating the dynamic simulation model of the composite solar phase change thermal storage combined with an air-cooled heat pump system, the results show that the solar heating system with a PCM storage tank (SHS-PCM) saves 34% more energy than a solar heating system with a common tank (SHS-without PCM), and the volume of the PCM storage tank is reduced to 1/5 of the ordinary tank. The investment payback period method of energy saving reconstruction is used to analyze the economy of the SHS-PCM and the SHS-without PCM, the initial investment cost of the SHS-PCM is CNY 9858 higher than the SHS-without PCM, but the annual operation cost is saved by CNY 12,100, and the project investment payback period is 0.81 years, which has energy-saving potential and economic benefits.

15 September 2023 in Buildings
Verified
Journal Article
Open access
PDF file
WLWang Liang
Wang Liang
YLYangli Li
Yangli Li
SDShudan Deng
Shudan Deng
JZJuan Zhao
Juan Zhao
The research focuses on the air-conditioning system in a public area of a subway station. To address this, an optimization model based on the grid time segmentation method was constructed, specifically a GM (1,1) model. We explored the influence of the hourly passenger flow fluctuation on the load of the subway air-conditioning system, obtained the dynamic change law of the air conditioning system load in the subway station, and then dynamically adjusted the air conditioning system according to the dynamic change law to reduce the operation energy consumption of the system. Through the analysis of the simulation results, the model predicted that compared with the actual passenger flow data, the average maximum relative error was 14.97%. On this basis, the change law of the dynamic load of the subway air-conditioning system which caused by the change in passenger flow from time to time could be calculated and analyzed. Compared with the calculated load of the air conditioning system, the working day load was decreased by 1469.77 kW, or 22.00%. The findings indicate that in response to the dynamic load of fluctuations, timely adjustment of the air supply parameter of the air-conditioning system offers a significant reference point for optimizing energy efficiency in subway stations.

19 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
JZJuan Zhao
Juan Zhao
YBYifei Bai
Yifei Bai
ZTZhou Bo Tao
Zhou Bo Tao
GJGao Junmei
Gao Junmei
TQTianwei Qiang
Tianwei Qiang
Pei LiangPei Liang
Pei Liang
The variability and inhomogeneity of solar energy limits the development of solar heating systems (SHS) in many fields. In order to improve the utilization efficiency of SHS, this paper takes three typical cities (Xi’an, Dunhuang, Lhasa) as the research object, studies the operation state of SHS in student dormitory buildings, and puts forward a corresponding optimization strategy. The research shows that the reduction of water supply temperature will improve the operation efficiency and energy saving effect of a spontaneous combustion heat pump and that there is an optimal volume of heat storage water tank (HSWT), which can make the energy saving effect of SHS run better. The optimization of the SHS shows the water supply temperature is 35 °C, and the optimal volume of HSWT is 15 m3 in the “Resource-general area (Ⅲ)” represented by Xi’an, 25 m3 in the “Resource-rich area (Ⅱ)” represented by Dunhuang, and 40 m3 in the “Resource-richer area (Ⅰ)” represented by Lhasa. With the increase in the abundance of solar energy resources in the region, the optimal volume of HSWT also increases. Meanwhile, the solar energy contribution rate of the three regions in descending order is 61.3% (Lhasa), 32.8% (Dunhuang), and 25.9% (Xi’an). After optimization, the contribution of SHS increased by about 5%. The research results will help improve the efficiency of SHS in cold areas of China and make the system more efficient and energy efficient during operation.

4 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
JZJuan Zhao
Juan Zhao
YBYifei Bai
Yifei Bai
GJGao Junmei
Gao Junmei
TQTianwei Qiang
Tianwei Qiang
Pei LiangPei Liang
Pei Liang
The instability of solar energy and its resource distribution characteristics make it difficult to judge its suitability in practical engineering applications, which hinders its promotion and application. In order to better promote the effective use of solar energy and promote the solar heating system, it is necessary to put forward a simple method of judging the suitability of the solar heating system for engineering application. This study puts forward “F, Q” as the basis for judging the suitability of solar heating systems built on the roof. Two types of public buildings, office buildings and three-star hotels, are taken as the research objects. DeST software is used to change the heating area of the building by superimposing floors to simulate the heat load of the building when the heating area changes. A dynamic simulation coupling model of solar heating system is established in the TRNSYS software to analyze the operating status of the system under all working conditions. The functional relationship between “F, Q” and solar energy guarantee rate is established, and the solar energy contribution rate is divided into three regions of F < 30%, 30% ≤ F ≤ 50%, and F > 50%. The evaluation standard of the building suitability of the solar energy heating system is established according to the scope of “F, Q” in different regions (An office building for, e.g., if the contribution rate of solar heating system is required to be greater than 50%, the “F” of these four areas should be greater than 0.11388, 0.15543, 0.10572, and 0.04511.), and the effectiveness of “F” is verified through actual cases verified by other scholars in the research. The method proposed in this paper is helpful to judge the suitability of solar heating systems in different regions and different types of conventional buildings, so as to better promote solar heating systems.